Optimized workflow with hybrid (very) high-power short-duration radiofrequency ablation renders point-by-point pulmonary vein isolation as fast and effective as cryoballoon ablation

被引:0
|
作者
Fusaroli, Marco [1 ,2 ]
Hoogendijk, Mark G. [1 ]
Bhagwandien, Rohit E. [1 ]
Wijchers, Sip A. [1 ]
van Boven, Nick [1 ,3 ]
Mahmoodi, Bakthawar K. [1 ]
Yap, Sing-Chien [1 ]
机构
[1] Erasmus MC, Cardiovasc Inst, Thorax Ctr, Dept Cardiol, Rotterdam, Netherlands
[2] Univ Florence, Careggi Univ Hosp, Sch Human Hlth Sci, Dept Expt & Clin Med, Florence, Italy
[3] Franciscus Gasthuis & Vlietland, Dept Cardiol, Rotterdam, Netherlands
关键词
Atrial fibrillation; Cryoballoon ablation; High power short duration; Very high power short duration; Atrial arrhythmia recurrence;
D O I
10.1007/s10840-025-01982-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction A hybrid approach with very high-power short-duration (vHPSD) posteriorly and ablation-index guided HPSD (50 W) anteriorly seems to be an optimal balance between efficiency and effectiveness for point-by-point pulmonary vein isolation (PVI). The aim of the current study is to compare vHPSD/HPSD ablation to cryoballoon ablation (CBA) in patients with symptomatic atrial fibrillation (AF). Methods and results In this retrospective single-center study, we identified 110 consecutive patients who underwent their first PVI with either vHPSD/HPSD (n = 54) or CBA (n = 56). We compared procedural efficacy, efficiency, safety, and long-term outcomes. Baseline characteristics of both groups were comparable; however, patients in the vHPSD/HPSD group had larger left atrial volume index (35, IQR 27-45 vs. 28, IQR 21-36 ml/m(2), P = 0.005). Complete PVI was achieved in all patients except two CBA cases (100% vs. 96.4%, P = 0.50). First-pass isolation rate was 79.6% in the hybrid group. Procedure times were similar between groups (53, IQR 47-63 vs. 55, IQR 49-65 min, P = 0.35), but fluoroscopy time was shorter in the vHPSD/HPSD group (3.9 [2.7, 5.6] vs. 11.9 [9.3, 14.9] min, P < 0.001). There were 3 temporary phrenic nerve palsies (5.4%) in the CBA group which resolved within 1 year. The 1-year freedom from any atrial tachyarrhythmias after a single procedure was similar between groups (68.5% vs. 73.2%, P = 0.56). During repeat procedure, the durability of PVI was comparable. Conclusions The use of vHPSD/HPSD ablation renders point-by-point PVI as fast and effective as CBA. Furthermore, it has lower radiation exposure compared to CBA.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] High-power, Short-duration Radiofrequency Ablation of Atrial Fibrillation: Point-by-Point or Catheter Dragging Technique?
    Fenelon, Guilherme
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2025, 121 (12)
  • [2] Very High-Power very Short-Duration versus a Hybrid Ablation Approach for Contiguous Pulmonary Vein Isolation
    Baumgartner, A.
    Nocker, C.
    Derndorfer, M.
    Kollias, G.
    Martinek, M.
    Puererfellner, H.
    Seidl, S.
    WIENER KLINISCHE WOCHENSCHRIFT, 2023, 135 : S414 - S414
  • [3] Update on high-power short-duration ablation for pulmonary vein isolation
    Qiu, Jie
    Wang, Yan
    Wang, Dao W.
    Hu, Mei
    Chen, Guangzhi
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (09) : 2499 - 2508
  • [4] Biophysical parameters of pulmonary vein isolation with very high-power short-duration compared to conventional radiofrequency ablation guided by ablation index
    Duarte, F. Fabiana
    Silva-Teixeira, R.
    Almeida, J. Goncalves
    Fonseca, P.
    Oliveira, M.
    Goncalves, H.
    Primo, J.
    Fontes-Carvalho, R.
    EUROPEAN JOURNAL OF HEART FAILURE, 2024, 26 : 6 - 6
  • [5] High-power short-duration ablation: The new standard for pulmonary vein isolation?
    Chaldoupi, Sevasti-Maria
    Luermans, Justin
    Vernooy, Kevin
    Linz, Dominik
    IJC HEART & VASCULATURE, 2021, 36
  • [6] High-Power and Short-Duration Ablation for Pulmonary Vein Isolation Biophysical Characterization
    Leshem, Eran
    Zilberman, Israel
    Tschabrunn, Cory M.
    Barkagan, Michael
    Contreras-Valdes, Fernando M.
    Govari, Assaf
    Anter, Elad
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (04) : 467 - 479
  • [7] How much is enough? An appraisal of high-power short-duration radiofrequency ablation for pulmonary vein isolation
    Raja, Deep Chandh
    Sanders, Prashanthan
    Pathak, Rajeev K.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (11) : 2205 - 2208
  • [8] Biophysical Behavior of Very High-Power Short-Duration Radiofrequency Ablation in Pulmonary Vein Isolation: Fast but Gently-Implications for a Successful Procedure
    Celentano, Eduardo
    Cristiano, Ernesto
    Ignatiuk, Barbara
    Bia, Elena
    Girotto, Lorenzo
    Tarantino, Nicola
    De Groot, Natasja M. S.
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (23)
  • [9] Ablation Parameters Predicting Pulmonary Vein Reconnection after Very High-Power Short-Duration Pulmonary Vein Isolation
    Boga, Marton
    Orban, Gabor
    Sallo, Zoltan
    Nagy, Klaudia Vivien
    Osztheimer, Istvan
    Ferencz, Arnold Bela
    Komlosi, Ferenc
    Toth, Patrik
    Tanai, Edit
    Perge, Peter
    Merkely, Bela
    Geller, Laszlo
    Szegedi, Nandor
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2024, 11 (08)
  • [10] Can lesion parameters predict effective pulmonary vein isolation in very-high-power short-duration radiofrequency ablation?
    Koev, I.
    Mavilakandy, A.
    Kotb, A.
    Antoun, I.
    Vali, Z.
    Barker, J.
    Sidhu, B.
    Pooranachandran, V.
    Li, X.
    Ng, G. Andre
    EUROPEAN HEART JOURNAL, 2022, 43 : 476 - 476