Relation between change of effective lens position and toric IOL rotation after toric IOL implantation

被引:0
|
作者
Na, Kyung-Sun [1 ]
An, Dohyeon [1 ]
Kim, Hyun Seung [1 ]
Kim, Eun Chul [1 ]
机构
[1] Catholic Univ Korea, Coll Med, Dept Ophthalmol & Visual Sci, Seoul, South Korea
关键词
CORNEAL ASTIGMATISM; POWER;
D O I
10.1016/j.jcjo.2024.05.011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To evaluate the relationship between change of effective lens position (ELP) and toric intraocular lens (IOL) rotation in patients with increasing postoperative refractive astigmatism after successful toric IOL implantation. Methods: The subjects include 61 people (61 eyes) with increasing residual astigmatism >0.5 D 3 months after successful toric IOL implantation. Clinical measurements included preoperative, 1-week, and 1-, 2-, and 3-month postoperative visual acuity; refraction; keratometer; anterior and posterior corneal astigmatism; ELP by Scheimpflug camera imaging; and IOL axis by slit-lamp biomicroscopic photograph with pupil dilation. Results: Residual astigmatism in postoperative month 3 (0.81 +/- 0.50 D) is higher than that at postoperative week 1 (0.41 +/- 0.38 D; p < 0.05). ELP decreased by 264.44 +/- 163.25 mu m, and the IOL rotated by 2.91 +/- 1.44 degrees from week 1 to month 3 (p < 0.05). The ELP change had a positive correlation with IOL rotation (R-2 = 0.383; p = 0.006), and the postoperative refractive astigmatic change had a positive correlation with ELP change (R-2 = 0.272; p = 0.027) and IOL rotation (R-2 = 0.272; p = 0.0001) from week 1 to month 3. Conclusion: ELP change can influence toric IOL rotation and increase residual astigmatism after toric IOL implantation.
引用
收藏
页码:8 / 14
页数:7
相关论文
共 50 条
  • [1] Relation between Change of Effective Lens Position and Intraocular Lens rotation after Toric IOL Implantation.
    Kim, Eun Chul
    Shin, Da Young
    Kim, Man Soo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [2] CATARACT SURGERY SURPRISES AFTER TORIC IOL IMPLANTATION
    Alpins, Noel
    Stamatelatos, George
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 43 : 41 - 41
  • [3] Toric intraocular lens outcomes with a new protocol for IOL selection and implantation
    Clark, K. D.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2018, 41 (02): : 145 - 151
  • [4] Efficacy evaluation of toric IOL rotation after cataract surgery
    Ohashi, Tsutomu
    Shinkai, Akihiro
    Lawu, Tjundewo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (07): : 961 - 962
  • [5] TORIC IOL IMPLANTATION IN FEMTOSECOND CATARACT SURGERY
    Lawless, Michael
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 : 13 - 13
  • [6] Clinical differences between toric intraocular lens (IOL) and monofocal intraocular lens (IOL) implantation when myopia is determined as target refraction
    Shin, Da Young
    Hwang, Ho Sik
    Kim, Hyun Seung
    Kim, Man Soo
    Kim, Eun Chul
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [7] Clinical differences between toric intraocular lens (IOL) and monofocal intraocular lens (IOL) implantation when myopia is determined as target refraction
    Da Young Shin
    Ho Sik Hwang
    Hyun Seung Kim
    Man Soo Kim
    Eun Chul Kim
    BMC Ophthalmology, 21
  • [8] Rotational stability and patient satisfaction after implantation of a new toric IOL
    Gyoengyoessy, Balazs
    Jirak, Paul
    Schoenherr, Ulrich
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (04) : 321 - 327
  • [9] Visual performance after toric IOL implantation in patients with corneal astigmatism
    Bett Correia, Renato Jose
    Moreira, Hamilton
    Lago Netto, Solon Uchoa
    Pantaleao, Gleisson Rezende
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2009, 72 (05) : 636 - 640
  • [10] Agreement Between Pentacam and IOLMaster in Patients Undergoing Toric IOL Implantation
    Lee, Bradford W.
    Galor, Anat
    Feuer, William J.
    Pouyeh, Bozorgmehr
    Pelletier, Jesse S.
    Vaddavalli, Pravin K.
    Lemelman, Benjamin T.
    See, Craig
    Yoo, Sonia H.
    JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (02) : 114 - 120