Optimization of Scan Parameters for in vivo Hyperpolarized Carbon-13 Magnetic Resonance Spectroscopic Imaging

被引:1
|
作者
Nguyen, Nguyen Trong [1 ]
Rasanjala, Onila N. M. D. [2 ]
Park, Ilwoo [2 ,3 ,4 ]
机构
[1] Chonnam Natl Univ, Dept Biomed Sci, Gwangju, South Korea
[2] Chonnam Natl Univ, Dept Artificial Intelligence Convergence, Gwangju, South Korea
[3] Chonnam Natl Univ Med Sch & Hosp, Dept Radiol, Gwangju, South Korea
[4] Chonnam Natl Univ, Dept Data Sci, 5 Dong,Rm 105,42 Jaebong Ro, Gwangju 61469, South Korea
关键词
Hyperpolarized; DNP; pyruvate; Magnetic resonance spectroscopic imaging; METABOLISM; RECONSTRUCTION; PARALLEL;
D O I
10.13104/imri.2022.26.2.125
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to investigate the change in signal sensitivity over different acquisition start times and optimize the scanning window to provide the maximal signal sensitivity of [1-13C]pyruvate and its metabolic products, lactate and alanine, using spatially localized hyperpolarized 3D 13C magnetic resonance spectroscopic imaging (MRSI). Materials and Methods: We acquired 3D 13C MRSI data from the brain (n = 3), kidney (n = 3), and liver (n = 3) of rats using a 3T clinical scanner and a custom RF coil after the injection of hyperpolarized [1-13C]pyruvate. For each organ, we obtained three consecutive 3D 13C MRSI datasets with different acquisition start times per animal from a total of three animals. The mean signal-to-noise ratios (SNRs) of pyruvate, lactate, and alanine were calculated and compared between different acquisition start times. Based on the SNRs of lactate and alanine, we identified the optimal acquisition start timing for each organ. Results: For the brain, the acquisition start time of 18 s provided the highest mean SNR of lactate. At 18 s, however, the lactate signal predominantly originated from not the brain, but the blood vessels; therefore, the acquisition start time of 22 s was recommended for 3D 13C MRSI of the rat brain. For the kidney, all three metabolites demonstrated the highest mean SNR at the acquisition start time of 32 s. Similarly, the acquisition start time of 22 s provided the highest SNRs for all three metabolites in the liver. Conclusion: In this study, the acquisition start timing was optimized in an attempt to maximize metabolic signals in hyperpolarized 3D 13C MRSI examination with [1-13C] pyruvate as a substrate. We investigated the changes in metabolic signal sensitivity in the brain, kidney, and liver of rats to establish the optimal acquisition start time for each organ. We expect the results from this study to be of help in future studies.
引用
收藏
页码:125 / 134
页数:10
相关论文
共 50 条
  • [1] The use of hyperpolarized carbon-13 magnetic resonance for molecular imaging
    Siddiqui, Sarmad
    Kadlecek, Stephen
    Pourfathi, Mehrdad
    Xin, Yi
    Mannherz, William
    Hamedani, Hooman
    Drachman, Nicholas
    Ruppert, Kai
    Clapp, Justin
    Rizi, Rahim
    ADVANCED DRUG DELIVERY REVIEWS, 2017, 113 : 3 - 23
  • [2] Hyperpolarized carbon-13 magnetic resonance spectroscopic imaging: a clinical tool for studying tumour metabolism
    Zaccagna, Fulvio
    Grist, James T.
    Deen, Surrin S.
    Woitek, Ramona
    Lechermann, Laura M. T.
    McLean, Mary A.
    Basu, Bristi
    Gallagher, Ferdia A.
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1085):
  • [3] Determination of cardiac metabolism in vivo with hyperpolarized carbon-13 magnetic resonance
    Schroeder, Marie A.
    Cochlin, Lowri E.
    Radda, George K.
    Clarke, Kieran
    Tyler, Damian J.
    CIRCULATION RESEARCH, 2007, 101 (11) : 1211 - 1211
  • [4] Hyperpolarized Carbon-13 Magnetic Resonance Imaging: Technical Considerations and Clinical Applications
    Lai, Ying-Chieh
    Hsieh, Ching-Yi
    Juan, Yu -Hsiang
    Lu, Kuan-Ying
    Lee, Hsien-Ju
    Ng, Shu-Hang
    Wan, Yung-Liang
    Lin, Gigin
    KOREAN JOURNAL OF RADIOLOGY, 2024, 25 (05) : 459 - 472
  • [5] Combined parallel and partial fourier MR reconstruction for accelerated 8-channel hyperpolarized carbon-13 in vivo magnetic resonance Spectroscopic imaging (MRSI)
    Ohliger, Michael A.
    Larson, Peder E. Z.
    Bok, Robert A.
    Shin, Peter
    Hu, Simon
    Tropp, James
    Robb, Fraser
    Carvajal, Lucas
    Nelson, Sarah J.
    Kurhanewicz, John
    Vigneron, Daniel B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (03) : 701 - 713
  • [6] In vivo assessment of pyruvate dehydrogenase flux in the heart using hyperpolarized carbon-13 magnetic resonance
    Schroeder, Marie A.
    Cochlin, Lowri E.
    Heather, Lisa C.
    Clarke, Kieran
    Radda, George K.
    Tyler, Damian J.
    Shulman, Robert G.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2008, 105 (33) : 12051 - 12056
  • [7] In Vivo Monitoring of Rat Spinal Cord Metabolism Using Hyperpolarized Carbon-13 MR Spectroscopic Imaging
    Park, I.
    Nelson, S. J.
    Talbott, J. F.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (12) : 2407 - 2409
  • [8] Tumor Microenvironment Biosensors for Hyperpolarized Carbon-13 Magnetic Resonance Spectroscopy
    Changhua Mu
    David E. Korenchan
    Sinan Wang
    David M. Wilson
    Robert R. Flavell
    Molecular Imaging and Biology, 2021, 23 : 323 - 334
  • [9] Tumor Microenvironment Biosensors for Hyperpolarized Carbon-13 Magnetic Resonance Spectroscopy
    Mu, Changhua
    Korenchan, David E.
    Wang, Sinan
    Wilson, David M.
    Flavell, Robert R.
    MOLECULAR IMAGING AND BIOLOGY, 2021, 23 (03) : 323 - 334
  • [10] Optimal experiment design for physiological parameter estimation using hyperpolarized carbon-13 magnetic resonance imaging
    Maidens, John
    Larson, Peder E. Z.
    Arcak, Murat
    2015 AMERICAN CONTROL CONFERENCE (ACC), 2015, : 5770 - 5775