Advancing personalized medicine in digital health: The role of artificial intelligence in enhancing clinical interpretation of 24-h ambulatory blood pressure monitoring

被引:0
|
作者
Alam, Sreyoshi F. [1 ]
Thongprayoon, Charat [1 ]
Miao, Jing [1 ]
Pham, Justin H. [1 ]
Sheikh, Mohammad S. [1 ]
Valencia, Oscar A. Garcia [1 ]
Schwartz, Gary L. [1 ]
Craici, Iasmina M. [1 ]
Suarez, Maria L. Gonzalez [1 ]
Cheungpasitporn, Wisit [1 ]
机构
[1] Mayo Clin, Dept Internal Med, Div Nephrol & Hypertens, Rochester, MN 55905 USA
来源
DIGITAL HEALTH | 2025年 / 11卷
关键词
Digital health; artificial intelligence; 24-h ambulatory blood pressure monitoring; hypertension; personalized medicine; chatGPT; clinical decision support; nocturnal hypertension; nocturnal dipping; heart rate analysis;
D O I
10.1177/20552076251326014
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: The use of artificial intelligence (AI) for interpreting ambulatory blood pressure monitoring (ABPM) data is gaining traction in clinical practice. Evaluating the accuracy of AI models, like ChatGPT 4.0, in clinical settings can inform their integration into healthcare processes. However, limited research has been conducted to validate the performance of such models against expert interpretations in real-world clinical scenarios. Methods: A total of 53 ABPM records from Mayo Clinic, Minnesota, were analyzed. ChatGPT 4.0's interpretations were compared with consensus results from two experienced nephrologists, based on the American College of Cardiology/American Heart Association (ACC/AHA) guidelines. The study assessed ChatGPT's accuracy and reliability over two rounds of testing, with a three-month interval between rounds. Results: ChatGPT achieved an accuracy of 87% for identifying hypertension, 89% for nocturnal hypertension, 81% for nocturnal dipping, and 94% for abnormal heart rate. ChatGPT correctly identified all conditions in 60% of ABPM records. The percentage agreement between the first and second round of ChatGPT's analysis was 81% in identifying hypertension, 85% in nocturnal hypertension, 89% in nocturnal dipping, and 94% in abnormal heart rate. There was no significant difference in accuracy between the first and second round (all p > 0.05). The Kappa statistic was 0.63 for identifying hypertension, 0.66 for nocturnal hypertension, 0.76 for nocturnal dipping, and 0.70 for abnormal heart rate. Conclusions: ChatGPT 4.0 demonstrates potential as a reliable tool for interpreting 24-h ABPM data, achieving substantial agreement with expert nephrologists. These findings underscore the potential for AI integration into hypertension management workflows, while highlighting the need for further validation in larger, diverse cohorts.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Role of Artificial Intelligence (AI) in Clinical Interpretation of 24-Hour Ambulatory Blood Pressure Monitoring
    Alam, Sreyoshi Fatima
    Suarez, Gonzalez Maria Lourdes
    Thongprayoon, Charat
    Miao Jing
    Sheikh, M. Salman
    Valencia, Garcia Oscar Alejandro
    Schwartz, Gary L.
    Craici, Iasmina
    Cheungpasitporn, Wisit
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2024, 35 (10):
  • [2] Limited reproducibility of 24-h ambulatory blood pressure monitoring
    Keren, Shay
    Leibowitz, Avshalom
    Grossman, Ehud
    Sharabi, Yehonatan
    CLINICAL AND EXPERIMENTAL HYPERTENSION, 2015, 37 (07) : 599 - 603
  • [3] Variation in paediatric 24-h ambulatory blood pressure monitoring interpretation by Canadian and UK physicians
    Isabella Z. Stefanova
    Manish D. Sinha
    Douglas J. Stewart
    Abdulaziz Bamhraz
    Anne Fournier
    Kevin C. Harris
    Guido Filler
    Damien Noone
    Chia Wei Teoh
    Janis Dionne
    Rahul Chanchlani
    Journal of Human Hypertension, 2023, 37 : 363 - 369
  • [4] Variation in paediatric 24-h ambulatory blood pressure monitoring interpretation by Canadian and UK physicians
    Stefanova, Isabella Z.
    Sinha, Manish D.
    Stewart, Douglas J.
    Bamhraz, Abdulaziz
    Fournier, Anne
    Harris, Kevin C.
    Filler, Guido
    Noone, Damien
    Teoh, Chia Wei
    Dionne, Janis
    Chanchlani, Rahul
    JOURNAL OF HUMAN HYPERTENSION, 2023, 37 (05) : 363 - 369
  • [5] Correction to: Variation in paediatric 24-h ambulatory blood pressure monitoring interpretation by Canadian and UK physicians
    Isabella Z. Stefanova
    Manish D. Sinha
    Douglas J. Stewart
    Abdulaziz Bamhraz
    Anne Fournier
    Kevin C. Harris
    Guido Filler
    Damien Noone
    Chia Wei Teoh
    Janis Dionne
    Rahul Chanchlani
    Journal of Human Hypertension, 2022, 36 : 941 - 941
  • [6] TEMPORAL ANALYSIS OF BLOOD-PRESSURE BY AMBULATORY 24-H BLOOD-PRESSURE MONITORING
    LIBRETTI, A
    LATTUADA, S
    RINDI, M
    GRILLO, A
    SALVAGGIO, A
    CLINICAL AND EXPERIMENTAL HYPERTENSION PART A-THEORY AND PRACTICE, 1985, 7 (2-3) : 463 - 467
  • [7] Sustained high blood pressure and 24-h ambulatory blood pressure monitoring in Tanzanian adolescents
    Mussa K. Nsanya
    Philip Ayieko
    Ramadhan Hashim
    Ezekiel Mgema
    Daniel Fitzgerald
    Saidi Kapiga
    Robert N. Peck
    Scientific Reports, 11
  • [8] Sustained high blood pressure and 24-h ambulatory blood pressure monitoring in Tanzanian adolescents
    Nsanya, Mussa K.
    Ayieko, Philip
    Hashim, Ramadhan
    Mgema, Ezekiel
    Fitzgerald, Daniel
    Kapiga, Saidi
    Peck, Robert N.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [9] Ability of a 24-h ambulatory cuffless blood pressure monitoring device to track blood pressure changes in clinical practice
    Derendinger, Felicia C.
    Vischer, Annina S.
    Krisai, Philipp
    Socrates, Thenral
    Schumacher, Christina
    Mayr, Michael
    Burkard, Thilo
    JOURNAL OF HYPERTENSION, 2024, 42 (04) : 662 - 671
  • [10] How reliable is isolated clinical hypertension defined by a single 24-h ambulatory blood pressure monitoring?
    Cuspidi, Cesare
    Meani, Stefano
    Sala, Carla
    Valerio, Cristiana
    Fusi, Veronica
    Zanchetti, Alberto
    Mancia, Giuseppe
    JOURNAL OF HYPERTENSION, 2007, 25 (02) : 315 - 320