Quinoid to benzenoid transition-driven glutathione sensing: Dual-emission carbon dots and smartphone-based ratiometric fluorescence analysis

被引:1
|
作者
Ali, Al-Montaser Bellah H. [1 ]
Mahmoud, Ashraf M. [1 ]
Jardan, Yousef A. Bin [2 ]
Mostafa, Aya M. [1 ]
Barker, James [3 ]
El-Wekil, Mohamed M. [1 ]
机构
[1] Assiut Univ, Fac Pharm, Dept Pharmaceut Analyt Chem, Assiut 71526, Egypt
[2] King Saud Univ, Coll Pharm, Dept Pharmaceut, Riyadh 11451, Saudi Arabia
[3] Kingston Univ, Sch Life Sci Pharm & Chem, London KT1 2EE, England
来源
TALANTA OPEN | 2025年 / 11卷
关键词
Glutathione; Ratiometric; Dual emission; Colorimetric; Smartphone; COLORIMETRIC DETECTION; REDUCTION;
D O I
10.1016/j.talo.2025.100418
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study presents a novel and sensitive method for the determination of glutathione (GSH), a crucial antioxidant and cellular protectant, using dual blue/orange-emitting carbon dots (BO-CDs) and phenolphthalein (PHP). The sensing system operates at pH 9.0, exploiting the unique optical properties of BO-CDs with emission peaks at 420 nm and 570 nm. In alkaline conditions, PHP develops a pink color that selectively quenches the 570 nm emission of the CDs while leaving the 420 nm peak unaffected. Upon introduction of GSH, the quinoid structure of PHP is converted to its benzenoid form via Michael addition, resulting in the disappearance of the pink color and subsequent restoration of the 570 nm fluorescence. This mechanism, utilized for the first time in GSH detection, offers a distinct advantage over previous methods that primarily relied on GSH's complexation capabilities. The analytical capabilities of the BO-CDs/PHP ratiometric probe were extensively evaluated through multiple spectroscopic methods to understand its sensing mechanism. Performance analysis revealed impressive analytical figures of merit: the method exhibited strong linearity with a correlation coefficient of 0.9985, provided sensitive detection across a broad concentration range from 0.01 to 8.0 mu M, and achieved a remarkably low detection limit of 3.33 nM. The method's versatility was enhanced through the development of a dual-mode smartphone platform, enabling both colorimetric and fluorometric GSH detection. Practical validation using human serum samples demonstrated the method's robustness in complex biological matrices, achieving high recovery rates between 98.5 % and 101.0 %, confirming its suitability for real-world clinical applications. This novel strategy combines the sensitivity of ratiometric fluorescence with the convenience of smartphone-based detection, offering a promising tool for GSH monitoring in clinical and research settings.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Dual-emission carbon dots for ratiometric fluorescence sensing of thiabendazole in fruits
    Yang, Song
    Zhu, Haimei
    Cai, Shenghao
    Chen, Zifan
    Liang, Xiao
    Li, Zhuo
    Peng, Nannan
    Wang, Jingmin
    Wang, Yongzhong
    TALANTA, 2024, 270
  • [2] Ratiometric fluorescence and smartphone-assisted sensing platform based on dual-emission carbon dots for brilliant blue detection
    Liu, Lizhen
    Chen, Meng
    Zhao, Ting
    Yuan, Lin
    Mi, Zhi
    Bai, Yunfeng
    Fei, Peng
    Liu, Zhixiong
    Li, Caiqing
    Wang, Ligang
    Feng, Feng
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 322
  • [3] A smartphone-based ratiometric fluorescent sensing system for on-site detection of pyrethroids by using blue-green dual-emission carbon dots
    Zhu, Xuecheng
    Han, Luxuan
    Liu, Huilin
    Sun, Baoguo
    FOOD CHEMISTRY, 2022, 379
  • [4] Construction of ratiometric fluorescence sensor and test strip with smartphone based on dual-emission carbon dots for the specific detection of chlortetracycline
    Wang, Chunyan
    Huang, Gengli
    Luo, Xueli
    Tang, Wenzhi
    Yue, Tianli
    Li, Zhonghong
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (28) : 8143 - 8154
  • [5] Construction of ratiometric fluorescence sensor and test strip with smartphone based on dual-emission carbon dots for the specific detection of chlortetracycline
    Chunyan Wang
    Gengli Huang
    Xueli Luo
    Wenzhi Tang
    Tianli Yue
    Zhonghong Li
    Analytical and Bioanalytical Chemistry, 2022, 414 : 8143 - 8154
  • [6] Carbon dots-based dual-emission ratiometric fluorescence sensor for dopamine detection
    An, Jia
    Chen, Meizhu
    Hu, Nan
    Hu, Yongqin
    Chen, Rubing
    Lyu, Ying
    Guo, Wenxi
    Li, Lijie
    Liu, Yufei
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2020, 243
  • [7] A ratiometric fluorescent probe for a smartphone-based dual-emission carbon dot fluorescence sensor for the rapid detection of 5-HIAA
    Han, Yuying
    Hou, Xingyu
    Li, Yali
    Yang, Xiaopeng
    Sun, Xue
    Bian, Xinxin
    Sun, Na
    Lv, Yuguang
    Ding, Lixin
    Li, Ze
    MICROCHEMICAL JOURNAL, 2025, 212
  • [8] Smartphone-based label-free ratiometric fluorescence detection of sertraline and glutathione based on the use of orange-emission carbon dots
    Meng, Yating
    Guo, Qiaozhi
    Jiao, Yuan
    Lei, Peng
    Shuang, Shaomin
    Dong, Chuan
    MATERIALS TODAY CHEMISTRY, 2022, 26
  • [9] Ratiometric dual-emission carbon dots coupled with smartphone for visual quantification of Co2+ and EDTA and biological sensing
    Dong, Xiaorui
    Shi, Lihong
    Zhou, Wei
    Shuang, Shaomin
    MICROCHEMICAL JOURNAL, 2023, 189
  • [10] Smartphone-Based Fluorescence Detection of Al3+ and H2O Based on the Use of Dual-Emission Biomass Carbon Dots
    Rao, Hanbing
    Liu, Wei
    He, Keqiao
    Zhao, Shun
    Lu, Zhiwei
    Zhang, Shuxin
    Sun, Mengmeng
    Zou, Ping
    Wang, Xianxiang
    Zhao, Qingbiao
    Wang, Yanying
    Liu, Tao
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2020, 8 (23) : 8857 - 8867