Ultrasound-Guided Venous Axillary Access Versus Standard Fluoroscopic Technique for Cardiac Lead Implantation ZEROFLUOROAXI Randomized Trial

被引:3
|
作者
Vitali, Francesco [1 ]
Malagu, Michele [1 ]
Bianchi, Nicola [1 ]
De Raffele, Martina
Manfrini, Marco [1 ,2 ]
Gibiino, Federico [1 ]
Boccadoro, Alberto [1 ]
Azzolini, Giorgia [1 ]
Balla, Cristina [1 ]
Bertini, Matteo [1 ]
机构
[1] Univ Ferrara, St Anna Univ Hosp, Cardiol Unit, Via A Moro 8, I-44124 Ferrara, FE, Italy
[2] Univ Ferrara, Ctr Clin & Epidemiol Res, Dept Med Sci, Ferrara, Italy
关键词
axillary venous access; ICD; pacemaker; ultrasound; venous access; CEPHALIC VEIN CUTDOWN; ELECTRONIC DEVICES; PACEMAKER; PUNCTURE; SOCIETY;
D O I
10.1016/j.jacep.2023.11.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Axillary vein puncture (AVP) and cephalic vein surgical cutdown are recommended in international guidelines because of their low risk of pneumothorax and chronic lead complications. Directly visualizing and puncturing the axillary vein under ultrasound guidance reduces radiation exposure, provides direct needle visualization, and lowers periprocedural complications. Our hypothesis is that ultrasound-guided axillary access is safer and more feasible than the standard fluoroscopic technique. OBJECTIVES The purpose of this study was to assess the efficacy and safety of ultrasound-guided axillary venous access during cardiac lead implantation for pacemakers (PMs) and implantable cardioverter-defibrillator (ICD) implantations. METHODS Patients were randomized in a 1:1 fashion to either axillary venous access under fluoroscopic guidance or ultrasound-guided axillary venous access. The composite outcome, including pneumothorax, hemothorax, inadvertent arterial puncture, pocket hematoma, pocket infection, lead dislodgement, and death, was evaluated 30 days after implantation. RESULTS We randomized 270 patients into 2 groups: the standard group for fluoroguided AVP (n = 134) and the experimental group for ultrasound-guided AVP (n = 136). No disparities in baseline characteristics were observed between the groups. The median age of the patients was 81 years, with women comprising 41% of the population. The majority of patients received single- and dual-chamber PMs (87% vs 88%; P = 1.00), and slightly over 10% in both groups received ICDs (13% vs 12%; P = 0.85). In total, we placed 357 leads in PMs and 48 leads in ICDs. Among these, 295 leads were inserted via axillary vein access and 110 via cephalic vein access. Notably, the subclavian vein was never used as a vascular access. The composite outcome was lower in the ultrasound group according to intention-to-treat analysis (OR: 0.55; 95% CI: 0.31-0.99; P = 0.034). The main difference within the composite outcome was the lower incidence of inadvertent axillary arterial puncture in the experimental group (17% vs 6%; P = 0.004). The ultrasound group also exhibited lower total procedural x-ray exposure (10,344 mGy x cm2 vs 7,119 mGy x cm2; P = 0.002) while achieving the same rate of success at the first attempt (61% vs 69%; P = 0.375). CONCLUSIONS Ultrasound-guided AVP is safer than the fluoroscopy-guided approach because it achieves the same rate of acute success while maintaining low total procedural radiation exposure. Ultrasound AVP should be considered the optimal venous access method for cardiac lead implantation. (Ultrasound Guided Axillary Access vs Standard Fluoroscopic Technique for Cardiac Lead Implantation [ZEROFLUOROAXI]; NCT05101720) (J Am Coll Cardiol EP 2024;10:554-565) (c) 2024 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:554 / 565
页数:12
相关论文
共 50 条
  • [1] Ultrasound-guided axillary venous access for pediatric and adult congenital lead implantation
    Clark, Bradley C.
    Janson, Christopher M.
    Nappo, Lynn
    Pass, Robert H.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (02): : 166 - 170
  • [2] Ultrasound-guided Axillary Vein Puncture in Cardiac Lead Implantation: Time to Move to a New Standard Access?
    Tagliari, Ana Paula
    Kochi, Adriano Nunes
    Mastella, Bernardo
    Saadi, Rodrigo Petersen
    Ferrari, Andres di Leoni
    Dussin, Luiz Henrique
    de Moura, Leandro
    Martins, Marcio Rodrigo
    Saadi, Eduardo Keller
    Polanczyk, Carisi Anne
    ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2020, 9 (02) : 78 - 82
  • [3] Efficacy of ultrasound-guided axillary/subclavian venous approaches for pacemaker and defibrillator lead implantation: a randomized study
    Liccardo, Mattia
    Nocerino, Pasquale
    Gaia, Salzano
    Ciardiello, Carmine
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 51 (02) : 153 - 160
  • [4] Efficacy of ultrasound-guided axillary/subclavian venous approaches for pacemaker and defibrillator lead implantation: a randomized study
    Mattia Liccardo
    Pasquale Nocerino
    Salzano Gaia
    Carmine Ciardiello
    Journal of Interventional Cardiac Electrophysiology, 2018, 51 : 153 - 160
  • [5] Ultrasound guided axillary vein access: An alternative approach to venous access for cardiac device implantation
    Chandler, Jonathan K.
    Apte, Nachiket
    Ranka, Sagar
    Mohammed, Moghniuddin
    Noheria, Amit
    Emert, Martin
    Pimentel, Rhea
    Dendi, Raghuveer
    Reddy, Madhu
    Sheldon, Seth H.
    Fritzlen, John
    Weidling, Robert
    Lacy, Sean
    Al-Kofahi, Mejalli
    Cullom, Melissa
    Robinson, Alex
    Mahmood, Uzair
    Sami, Farhad
    Hacker, Ethan
    Naeem, Arslan
    Ramirez, Rigoberto
    Berenbom, Loren
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (02) : 458 - 465
  • [6] ULTRASOUND GUIDED AXILLARY VEIN ACCESS: AN ALTERNATIVE APPROACH FOR VENOUS ACCESS FOR CARDIAC DEVICE IMPLANTATION
    Chandler, Jonathan
    Apte, Nachiket
    Fritzlen, John
    Weidling, Robert
    Lacy, Sean
    Naeem, Arslan
    Reddy, Madhu
    Ramirez, Rigoberto
    Emert, Martin
    Berenbom, Loren
    Pimentel, Rhean Linette
    Dendi, Raghuveer
    Sheldon, Seth H.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 439 - 439
  • [7] Caudal tilt ultrasound-guided axillary venous access for transvenous pacing lead implant
    Kaul, Risheek
    Yang, Felix
    Shokr, Mohamed
    Jankelson, Lior
    Knotts, Robert J.
    Holmes, Douglas
    Aizer, Anthony
    Chinitz, Larry A.
    Barbhaiya, Chirag R.
    HEART RHYTHM, 2024, 21 (05) : 662 - 667
  • [8] Ultrasound-guided venous access for pmks and icds-randomized trial
    Liccardo, MMattia
    Nocerino, P.
    Borrino, A.
    Carbone, C.
    Follero, P.
    Ciardiello, C.
    Prato, L.
    Russo, A.
    Salzano, G.
    EUROPEAN JOURNAL OF HEART FAILURE, 2014, 16 : 332 - 332
  • [9] Ultrasound-guided peripheral venous access: Is it the standard of care?
    Tobias, Joseph D.
    ANAESTHESIA PAIN & INTENSIVE CARE, 2015, 19 (03) : 226 - 228
  • [10] Ultrasound versus fluoroscopy-guided axillary vein access for cardiac device implantation
    Bun, Sok-Sithikun
    Taghji, Philippe
    Squara, Fabien
    Massoure, Pierre-Laurent
    Deharo, Jean-Claude
    Ferrari, Emile