Time Domain Distance Protection of AC Transmission Line Near Inverter Station

被引:0
|
作者
Wang, Zhen [1 ]
Wu, Dali [1 ]
Tian, Jie [1 ]
Wang, Yongmao [1 ]
Chen, Yu [2 ]
Guo, Yingxiang [1 ]
机构
[1] Wuhan Second Ship Design & Res Inst, Wuhan, Peoples R China
[2] Huazhong Univ Sci & Technol, Wuhan, Peoples R China
来源
2024 IEEE 2ND INTERNATIONAL CONFERENCE ON POWER SCIENCE AND TECHNOLOGY, ICPST 2024 | 2024年
关键词
inverter station; distance protection; time domain; polarity comparison;
D O I
10.1109/ICPST61417.2024.10602303
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The AC line fault near the LCC-HVDC inverter station usually causes commutation failures (CFs). The accuracy of power frequency phasor extraction will be affected by the distortion of fault voltage and current waveform, resulting in deterioration of power frequency phasor distance protection performance. The adaptability of the traditional power frequency phasor distance protection is analyzed by simulation. Then, according to the AC line RL model, a time domain distance element based on the polarity comparison of the instantaneous voltage at the protection installation and the instantaneous voltage of the setting point compensation is proposed. The proposed time domain distance element is not affected by the nonlinear output characteristics of the inverter station. Finally, the effectiveness of the time domain distance protection is verified by simulation.
引用
收藏
页码:315 / 320
页数:6
相关论文
共 50 条
  • [1] Waveform Distance Coefficient Based Directional Element for AC Transmission Line Protection Near Inverter Station
    Ji X.
    Liu D.
    Xiong P.
    Chen Y.
    Yang L.
    Wen M.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2024, 48 (01): : 140 - 149
  • [2] Pilot protection based on quasi power theorem for AC transmission line connected to inverter station
    Liu, Zhen
    Peng, Fang
    Gao, Houlei
    Yuan, Tong
    Xu, Bin
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 155
  • [3] A fast boundary protection for an AC transmission line connected to an LCC-HVDC inverter station
    Zhen Liu
    Houlei Gao
    Sibei Luo
    Le Zhao
    Yuyao Feng
    Protection and Control of Modern Power Systems, 2020, 5
  • [4] Novel pilot protection for AC transmission line connected to LCC-HVDC inverter station
    Wang, Dong
    Hou, Mengqian
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 108 : 347 - 358
  • [5] A fast boundary protection for an AC transmission line connected to an LCC-HVDC inverter station
    Liu, Zhen
    Gao, Houlei
    Luo, Sibei
    Zhao, Le
    Feng, Yuyao
    PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2020, 5 (01)
  • [6] Long transmission line distance protection based on parameter identification in time domain
    Song, Guobing
    Liu, Linlin
    Suonan, Jiale
    Yuan, Xiaohui
    Du, Bin
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2009, 33 (18): : 67 - 70
  • [7] Minimum distance between AC transmission line and seismic observation station
    Qi, Lei
    Cui, Xiang
    Wu, Yan
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (03): : 649 - 654
  • [8] High Resistance Grounding Fault Protection of AC Line Near Converter Station at Inverter Side of LCC-HVDC
    LCC‑HVDC逆变侧换流站近区交流线路高阻接地故障保护
    1600, Automation of Electric Power Systems Press (45): : 162 - 169
  • [9] Adaptive Distance Protection for Transmission Line of Photovoltaic Station During Asymmetric Short Circuit
    Chao C.
    Zheng X.
    Gao P.
    Tai N.
    Jin S.
    Tu Q.
    Sun T.
    Li W.
    An Y.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (18): : 6681 - 6692
  • [10] A time-domain distance protection method applicable to inverter-interfaced systems
    Song, Guobing
    Chang, Peng
    Hou, Junjie
    Li, Weijia
    Zhang, Chenhao
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 225