Assessing thermal performance: Dataset from an experimental study on U-value variability

被引:2
|
作者
Alkhatib, H. [1 ,2 ,4 ]
Norton, B. [1 ,2 ,4 ,5 ]
Gavin, D. [3 ]
Lemarchand, P. [2 ,3 ,4 ]
机构
[1] Technol Univ Dublin, Sch Mech Engn, Dublin, Ireland
[2] Technol Univ Dublin, Dublin Energy Lab, Dublin, Ireland
[3] Technol Univ Dublin, Sustainabil Intelligence, Dublin, Ireland
[4] SFI Ctr Energy Climate & Marine, MaREI, Cork, Ireland
[5] Univ Coll Cork, Tyndall Natl Inst, Int Energy Res Ctr, IERC, Cork, Ireland
来源
DATA IN BRIEF | 2024年 / 57卷
关键词
U-value; Energy audit; Thermal performance; Building efficiency; Insulation;
D O I
10.1016/j.dib.2024.111067
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In order to achieve energy savings in existing buildings, there is an increasing need for energy audits and performance checks. In this regard, estimating a building's U-value is crucial, and there are a variety of methods available for achieving this. Heat flow meters can be used to measure U-value in situ. This dataset reports on an experimental campaign that evaluated the insulation and performance of the fabric elements of a building located in Dublin, Ireland. The experimental study conducted on the "Block F" building provided insights into the building's thermal performance by measuring the U-value of various windows and walls across different locations and floors. The average heat loss coefficient for windows was approximately 1.74 W/(m(2)K) before data cleaning and 1.99 W/(m(2)K) after cleaning, while walls had an average of 0.90 W/(m(2)K) before cleaning and 1.07 W/(m(2)K) after cleaning. The findings demonstrated that similar types of windows and walls components gave significantly different U-values. (c) 2024 Published by Elsevier Inc. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/)
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Assessing thermal performance: An experimental study on U-value variability in building fabric elements
    Alkhatib, H.
    Lemarchand, P.
    RESULTS IN ENGINEERING, 2025, 25
  • [2] An Analysis of U-Value as a Measure of Variability
    Xiuyan Kong
    James S. McEwan
    Lewis A. Bizo
    T. Mary Foster
    The Psychological Record, 2017, 67 : 581 - 586
  • [3] An Analysis of U-Value as a Measure of Variability
    Kong, Xiuyan
    McEwan, James S.
    Bizo, Lewis A.
    Foster, T. Mary
    PSYCHOLOGICAL RECORD, 2017, 67 (04): : 581 - 586
  • [4] Experimental and numerical study of a novel composite building wall U-value
    Nath, Biswajit
    Roy, Sujit
    Das, Biplab
    Ehyaei, M. A.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 53
  • [5] THERMAL BRIDGING: SIGNIFICANCE IN U-vALUE CALCULATION.
    Siviour, J.B.
    Mould, A.E.
    Building Services Engineering Research and Technology, 1988, 9 (03) : 133 - 135
  • [6] Calculation and comparative analysis of thermal transmittance (U-value) of Scottish houses from recent centuries
    Rezvani, Fahimeh
    Zabalza Bribian, Ignacio
    INDOOR AND BUILT ENVIRONMENT, 2019, 28 (07) : 873 - 886
  • [7] Estimating surface temperature from thermal imagery of buildings for accurate thermal transmittance (U-value): A machine learning perspective
    Sadhukhan, Debanjan
    Peri, Sai
    Sugunaraj, Niroop
    Biswas, Avhishek
    Selvaraj, Daisy Flora
    Koiner, Katelyn
    Rosener, Andrew
    Dunlevy, Matt
    Goveas, Neena
    Flynn, David
    Ranganathan, Prakash
    JOURNAL OF BUILDING ENGINEERING, 2020, 32
  • [8] Quantitative thermography for the estimation of the U-value: state of the art and a case study
    Nardi, Iole
    Sfarra, Stefano
    Ambrosini, Dario
    32ND UIT (ITALIAN UNION OF THERMO-FLUID-DYNAMICS) HEAT TRANSFER CONFERENCE, 2014, 547
  • [9] Managing the uncertainty of the U-value measurement using an auxiliary set along with a thermal camera
    Papadakos, Georgios
    Marinakis, Vangelis
    Konstas, Christos
    Doukas, Haris
    Papadopoulos, Agis
    ENERGY AND BUILDINGS, 2021, 242
  • [10] Evaluation of aerial thermography for measuring the thermal transmittance (U-value) of a building façade
    Rodriguez, Marta Videras
    Melgar, Sergio Gomez
    Marquez, Jose Manuel Andujar
    ENERGY AND BUILDINGS, 2024, 324