Innovative full-range load operation solution for solar-aided power generation system: Enhancing efficiency with coal and solar energy flexibility integration

被引:0
|
作者
Huang, Guangqin [1 ]
Huang, Chang [1 ,2 ]
Huang, Huamao [1 ]
Liu, Han [1 ]
Wang, Weiliang [1 ,2 ]
机构
[1] Jinan Univ, Energy & Elect Res Ctr, Guangzhou 519070, Guangdong, Peoples R China
[2] Jinan Univ, MOE Key Lab Disaster & Control Engn, Guangzhou 510632, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Solar-aided coal-fired power generation; Full-range load operating solution; Operation optimization; Standard coal consumption; Environmental performance assessment; OPTIMIZATION; CARBON; PLANT; HEAT;
D O I
10.1016/j.energy.2025.134815
中图分类号
O414.1 [热力学];
学科分类号
摘要
Solar-aided coal-fired power generation (SAPG) has emerged as an efficient method for integrating solar energy into traditional power systems. Despite its potential, the simple application of traditional coal-fired unit operation solutions to SAPG plants can adversely impact coal-side performance, an issue often overlooked in the existing literature. This study introduces a novel full-range load operation solution (FLOS) for the SAPG system, termed FLOSSAPG, which harnesses the complementary flexibility of solar and coal energy to expand the high- efficiency valve point operating range within the governing stage. Key operational parameters, including the configuration of steam governing, initial steam pressure, solar input scale, and condenser pressure, undergo a collaborative optimization process aimed at minimizing the standard coal consumption of power supply (SCCPS). The findings indicate that the SAPG system with FLOSSAPG, achieves a significant average reduction in SCCPS, achieving 8.22 g/kWh across the full load range. To further the application of FLOSSAPG, an advanced operation strategy is proposed that surpasses conventional approaches in technical, economic, and environmental performance. The co-optimization of annual coal consumption and total capital cost identifies an optimal storage capacity of 3.5 hand a solar multiple of one. This leads to a substantial increase in annual net revenue of 2.19 x 106 USD (13.61 %). Moreover, there is a reduction in annual coal consumption by 1.90 x 105tons and in COQ emissions by 4.67 x 105 tons, respectively.
引用
收藏
页数:19
相关论文
共 26 条
  • [1] Analysis of CO2Abatement Cost of Solar Energy Integration in a Solar-Aided Coal-Fired Power Generation System in China
    Zhao, Jun
    Yang, Kun
    SUSTAINABILITY, 2020, 12 (16)
  • [2] Energy and exergy evaluations of solar-aided double reheat coal-fired power generation system
    Wu, Junjie
    Wu, Jiaming
    Han, Yu
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2023, 15 (04)
  • [3] Optimizing operation of a solar-aided coal-fired power system based on the solar contribution evaluation method
    Zhai Rongrong
    Zhao Miaomiao
    Tan Kaiyu
    Yang Yongping
    APPLIED ENERGY, 2015, 146 : 328 - 334
  • [4] A study on a novel solar contribution evaluation method for the solar-aided coal-fired power generation system
    Jiang, Yue
    Duan, Liqiang
    Tong, Yongjing
    Yang, Ming
    Pang, Liping
    FRONTIERS IN ENERGY RESEARCH, 2022, 10
  • [5] Operation strategy of solar-aided coal-fired power plant with heat storage system
    Zhai, Rongrong
    Zhao, Miaomiao
    Li, Chao
    Chen, Ying
    Yang, Yongping
    CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 479 - 484
  • [6] THERMAL PERFORMANCE ANALYSIS OF SOLAR-AIDED COAL-FIRED POWER GENERATION SYSTEM UNDER TWO TYPICAL OPERATION MODES
    Xiao Y.
    Guo T.
    Yu T.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2023, 44 (05): : 121 - 127
  • [7] Efficiency enhancement of solar-aided coal-fired power plant integrated with thermal energy storage under varying power loads and solar irradiances
    Yan, Hui
    Wang, Zhu
    Ding, Yuxing
    Liu, Ming
    Otitoju, Olajide
    Wang, Meihong
    Chong, Daotong
    JOURNAL OF ENERGY STORAGE, 2024, 94
  • [8] Exergy analysis of off-design performance in solar-aided power generation systems: Evaluating the rationality of using part-load operation solution of coal-fired plants
    Huang, Guangqin
    Huang, Chang
    Liu, Han
    Huang, Huamao
    Shang, Wentao
    Wang, Weiliang
    ENERGY, 2024, 302
  • [9] Analysis of a solar-aided coal-fired power generation system based on thermo-economic structural theory
    Zhai, Rongrong
    Liu, Hongtao
    Li, Chao
    Zhao, Miaomiao
    Yang, Yongping
    ENERGY, 2016, 102 : 375 - 387
  • [10] Optimization study of integration strategies in solar aided coal-fired power generation system
    Zhai, Rongrong
    Peng, Pan
    Yang, Yongping
    Zhao, Miaomiao
    RENEWABLE ENERGY, 2014, 68 : 80 - 86