Experimental Study of PEMFC Stack Performance Degradation Considering the Shutdown and Rest Processes

被引:0
|
作者
Zhao, Yan [1 ,2 ]
Luo, Maji [1 ,2 ,3 ]
Yang, Junwei [1 ,2 ]
Chen, Ben [1 ,2 ,3 ]
Sui, Pang-Chieh [1 ,2 ]
Zhou, Wei [1 ,2 ]
机构
[1] Wuhan Univ Technol, Hubei Key Lab Adv Technol Automot Components, Wuhan 430070, Hubei, Peoples R China
[2] Wuhan Univ Technol, Hubei Collaborat Innovat Ctr Automot Components Te, Wuhan 430070, Hubei, Peoples R China
[3] Wuhan Univ Technol, Hubei Key Lab Fuel Cells, Wuhan 430070, Hubei, Peoples R China
关键词
durability test; PEMFC; performance degradation; shutdown and rest process; voltage recovery phenomenon; MEMBRANE FUEL-CELL; DURABILITY; MECHANISMS; BEHAVIOR; CYCLES;
D O I
10.1155/er/3246950
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The improvement of durability is one of the most critical factors for expanding the commercialization of proton exchange membrane fuel cells (PEMFCs). Many experimental studies of continuous operation cycles have been carried out to gain an understanding of fuel cell durability, ignoring the shutdown and rest process. This paper performed durability tests over 1000 h in total, including the shutdown and rest processes, to investigate the impact of voltage recovery on cell degradation in real applications. Each durability test was operated only 8-10 h per day, and then the stack entered a shutdown and rest process. The results show that the voltage recovery after the shutdown and rest processes makes the fuel cells maintain the performance in the long term. The performance can be higher than the previous stage, which differs from the constant performance degradation observed in continuous tests. This paper specifically investigates the influence of operating conditions on durability, the characteristics of voltage degradation, and the underlying reasons for those phenomena during dynamic cycles that include shutdown and rest processes. The decrease in voltage uniformity is analyzed. The results indicate that imprecise control of the operating conditions could lead to a reduction in the fuel cell durability. During the processes of voltage degradation and recovery, marked improvements in performance are observed. Following the initial rapid decline in performance, the fuel cell degradation exhibited a strong correlation with the variations in voltage uniformity. Notably, the excessive degradation observed in a certain cell was the primary factor contributing to the reduction in voltage uniformity rather than the overall cell's nonuniform voltage. The shutdown and rest processes are crucial components of the dynamic cycles, and the mechanism of voltage recovery after the shutdown and rest processes should be focused on to improve the fuel cell life.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Thermodynamic and economic study of PEMFC stack considering degradation characteristic
    Chen, Xi
    Xu, Jianghai
    Yang, Chen
    Fang, Ye
    Li, Wenbin
    Zhang, Yan
    Wan, Zhongmin
    Wang, Xiaodong
    ENERGY CONVERSION AND MANAGEMENT, 2021, 235
  • [2] Experimental study on dynamic response performance for PEMFC stack
    Liu P.
    Xu S.
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2021, 40 (06): : 3172 - 3180
  • [3] Experimental study of dynamic performance of defective cell within a PEMFC stack
    Yu, Xingzi
    Zhang, Caizhi
    Fan, Min
    Deng, Bo
    Huang, Chengcheng
    Xu, Jiangfeng
    Liu, Deman
    Jiang, Shangfeng
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (13) : 8480 - 8491
  • [4] Performance Degradation of Dead-end Type PEMFC by Startup and Shutdown Cycles
    Jeong, Jaehyeun
    Jeong, Jaejin
    Song, Myunghyun
    Chung, Hoibum
    Na, Ilchai
    Lee, Ho
    Park, Kwonpil
    KOREAN CHEMICAL ENGINEERING RESEARCH, 2013, 51 (05): : 540 - 544
  • [5] Experimental analysis of performance degradation of 3-cell PEMFC stack under dynamic load cycle
    Han, Jaesu
    Han, Jaeyoung
    Yu, Sangseok
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2020, 45 (23) : 13045 - 13054
  • [6] Numerical analysis of PEMFC stack performance degradation using an empirical approach
    Zhao, Yan
    Luo, Maji
    Yang, Junwei
    Chen, Ben
    Sui, Pang-Chieh
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 56 : 147 - 163
  • [7] Experimental analysis of the CHP performance of a PEMFC stack by a 24 factorial design
    Torchio, MF
    Santarelli, MG
    Nicali, A
    JOURNAL OF POWER SOURCES, 2005, 149 : 33 - 43
  • [8] Experimental analysis of cathode flow stoichiometry on the electrical performance of a PEMFC stack
    Santarelli, M. G.
    Torchio, M. F.
    Cali, M.
    Giaretto, V.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2007, 32 (06) : 710 - 716
  • [9] Study of the influence of key test parameters on the performance of a PEMFC stack
    Harms, Corinna
    Koehrmann, Frank
    Dyck, Alexander
    SOLID STATE IONICS, 2015, 275 : 75 - 79
  • [10] Experimental study on temperature and performance of an open-cathode PEMFC stack under thermal radiation environment
    Zhang, Jikai
    Wang, Changjian
    Zhang, Aifeng
    APPLIED ENERGY, 2022, 311