Comparison between contrast-enhanced fat-suppressed 3D FLAIR brain MR images and T2-weighted orbital MR images at 3 Tesla for the diagnosis of acute optic neuritis

被引:0
|
作者
Manasse, Sharmiladevi [1 ]
Koskas, Patricia [1 ]
Savatovsky, Julien [1 ]
Deschamps, Romain [2 ]
Vignal-Clermont, Catherine [3 ]
de la Motte, Marine Boudot [2 ]
Papeix, Caroline [2 ]
Trunet, Stephanie [1 ]
Lecler, Augustin [1 ,4 ]
机构
[1] Fdn Adolphe Rothschild Hosp, Dept Neuroradiol, F-75019 Paris, France
[2] Fdn Adolphe Rothschild Hosp, Dept Neurol, F-75019 Paris, France
[3] Fdn Adolphe Rothschild Hosp, Dept Neuroophthalmol, F-75019 Paris, France
[4] Univ Paris Cite, Fac Med, F-75006 Paris, France
关键词
Imaging; FLAIR MRI; Magnetic resonance imaging; Multiple sclerosis; Optic neuritis; MULTIPLE-SCLEROSIS; REVISIONS; RISK;
D O I
10.1016/j.diii.2024.08.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to compare the capabilities of contrast-enhanced fat-suppressed (CE FS) three-dimensional fluid-attenuated inversion recovery (3D FLAIR) brain magnetic resonance imaging (MRI) with those of coronal T2-weighted orbital MRI obtained at 3 Tesla for the diagnosis of optic neuritis (ON). Materials and methods: Patients who presented to our center with acute visual loss and underwent MRI examination of the orbits and the brain between November 2014 and February 2020 were retrospectively included. Three radiologists independently and blindly analyzed CE FS 3D FLAIR and coronal T2-weighted images. Disagreements in image interpretation were resolved by consensus with an independent neuroradiologist who was not involved in the initial reading sessions. The primary adjudication criterion for the diagnosis of ON was the presence of an optic nerve hypersignal. Sensitivity, specificity, and accuracy of CE 3D FLAIR brain images were compared with those of coronal T2-weighted orbital images using McNemar test. Artifacts were classified into three categories and compared between the two image sets. Results: A total of 1023 patients were included. There were 638 women and 385 men with a mean age of 42 18.3 (standard deviation) years (age range: 6-92 years). Optic nerve hyperintensities were identified in 375/400 (94%) patients with ON using both 3D FLAIR and coronal T2-weighted images. Sensitivity, specificity, and accuracy of both sequences were 94% (95% CI: 91.3-96.1), 79% (95% CI: 75.5-82.2), and 89% (95% CI: 86.8 -90.7), respectively. Optic disc hypersignal was detected in 120/400 patients (30%) using 3D FLAIR compared to 3/400 (0.75%) using coronal T2-weighted images (P < 0.001). Optic radiation hypersignal was observed in 2/400 (0.5%) patients using 3D FLAIR images. Significantly more artifacts (moderate or severe) were observed on coronal T2-weighted images (801/1023; 78%) by comparison with 3D FLAIR images (448/1023; 44%) (P < 0.001). Conclusion: The performance of 3D FLAIR brain MRI for the diagnosis of ON is not different from that of coronal T2-weighted orbital MRI and its use for optic nerve analysis may be beneficial. (c) 2024 Soci & eacute;t & eacute; fran & ccedil;aise de radiologie. Published by Elsevier Masson SAS. All rights are reserved, including
引用
收藏
页码:481 / 488
页数:8
相关论文
共 50 条
  • [1] MR-IMAGING OF HEAD AND NECK TUMORS - COMPARISON OF T1-WEIGHTED CONTRAST-ENHANCED FAT-SUPPRESSED IMAGES WITH CONVENTIONAL T2-WEIGHTED AND FAST SPIN-ECHO T2-WEIGHTED IMAGES
    ROSS, MR
    SCHOMER, DF
    CHAPPELL, P
    ENZMANN, DR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (01) : 173 - 178
  • [2] MR imaging of osteomyelitis in diabetic feet: Relative conspicuousness on T1-weighted T2-weighted, STIR, and contrast-enhanced fat-suppressed T1-weighted images
    Judkiewicz, AM
    Colon, E
    Jelinek, JS
    Clement, S
    RADIOLOGY, 1996, 201 : 1440 - 1440
  • [3] Fat-suppressed MR Imaging of the Spine for Metal Artifact Reduction at 3T: Comparison of STIR and Slice Encoding for Metal Artifact Correction Fat-suppressed T2-weighted Images
    Lee, Young Han
    Hahn, Seok
    Kim, Eunju
    Suh, Jin-Suck
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2016, 15 (04) : 371 - 378
  • [4] Diagnostic value of contrast-enhanced 3D FLAIR sequence in acute optic neuritis
    Panyaping, Theeraphol
    Tunlayadechanont, Padcha
    Jindahra, Panitha
    Cheecharoen, Piyaphon
    NEURORADIOLOGY JOURNAL, 2023, 36 (06): : 674 - 679
  • [5] Comparison of 3D FLAIR, 2D FLAIR, and 2D T2-Weighted MR Imaging of Brain Stem Anatomy
    Kitajima, M.
    Hirai, T.
    Shigematsu, Y.
    Uetani, H.
    Iwashita, K.
    Morita, K.
    Komi, M.
    Yamashita, Y.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (05) : 922 - 927
  • [6] Fully automated segmentation of wrist bones on T2-weighted fat-suppressed MR images in early rheumatoid arthritis
    Wong, Lun Matthew
    Shi, Lin
    Xiao, Fan
    Griffith, James Francis
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (04) : 579 - 589
  • [7] MR signal intensity characteristics in Legg-Calve-Perthes disease -: Value of fat-suppressed (STIR) images and contrast-enhanced T1-weighted images
    Mahnken, AH
    Staatz, G
    Ihme, N
    Günther, RW
    ACTA RADIOLOGICA, 2002, 43 (03) : 329 - 335
  • [8] MR Diagnosis of Facial Neuritis: Diagnostic Performance of Contrast-Enhanced 3D-FLAIR Technique Compared with Contrast-Enhanced 3D-T1-Fast-Field Echo with Fat Suppression
    Lim, H. K.
    Lee, J. H.
    Hyun, D.
    Park, J. W.
    Kim, J. L.
    Lee, H. Y.
    Park, S.
    Ahn, J. H.
    Baek, J. H.
    Choi, C. G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (04) : 779 - 783
  • [9] UNSUPPRESSED FAT IN THE RIGHT ANTERIOR DIAPHRAGMATIC REGION ON FAT-SUPPRESSED T2-WEIGHTED FAST SPIN-ECHO MR-IMAGES
    YOSHIMITSU, K
    VARMA, DGK
    JACKSON, EF
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (02): : 145 - 149
  • [10] Contrast-Enhanced Radial 3D Fat-Suppressed T1-Weighted Gradient-Recalled Echo Sequence Versus Conventional Fat-Suppressed Contrast-Enhanced T1-Weighted Studies of the Head and Neck
    Wu, Xin
    Raz, Eytan
    Block, Tobias K.
    Geppert, Christian
    Hagiwara, Mari
    Bruno, Mary T.
    Fatterpekar, Girish M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (04) : 883 - 889