Design of On-Site Calibration Device for Electricity Meter Based on Pulse Detection

被引:0
|
作者
Wang, Yingchun [1 ]
Yu, Wenjing [1 ]
Zhang, Cheng [1 ]
Ye, Li [1 ]
Wei, Wei [1 ]
Yang, Zhixin [2 ]
机构
[1] State Grid Hubei Elect Power Co Mkt Serv Ctr Measu, Wuhan 430074, Peoples R China
[2] Shenzhen CLOU Elect Co Ltd, Shenzhen 518057, Peoples R China
关键词
electricity energy meter; on-site calibration; optimal frequency estimation; lock-frequency synchronous sampling; digital to frequency; electric energy pulse;
D O I
10.3390/inventions10010006
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
At present, the error calibration of electricity meters in operation generally adopts an off-site method; that is, the electricity meter is taken out of operation and then calibrated in the laboratory. Off-site calibration, while beneficial, may not fully capture the operational error of the electricity meter due to potential differences in environmental conditions. An on-site calibration device for electricity meters based on pulse detection is designed, which obtains the error of the electricity meter under calibration by comparing the energy pulses of the standard electricity meter with those of the electricity meter under calibration. High-precision voltage and current sampling channels are designed, with a voltage measurement error of less than 0.02% and a current measurement error of less than 0.03%. In response to the non-synchronous sampling problem caused by frequency fluctuations in the on-site verification environment, a fast optimal frequency estimation algorithm is applied to accurately calculate the signal frequency within two cycles. The sampling time interval is adjusted to achieve lock-frequency synchronous sampling, and ensure the accurate calculation of electrical parameters. In order to reduce the complexity of the device circuit structure and equipment cost, a standard electric energy pulses generation method based on digital integration-to-frequency is proposed, which uses software to generate electric energy pulses, with a maximum output frequency of up to 10 kHz. Tests conducted in the laboratory on the developed on-site calibration device for electricity meters show that its accuracy is better than the 0.05 accuracy class, meeting the application requirements for on-site verification of electricity energy meters.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] An Improved Design of the MultiCal On-Site Calibration Device for Industrial Robots
    Wan, Ziwei
    Zhou, Chunlin
    Lin, Zhaohui
    Yan, Huapeng
    Tang, Weixi
    Wang, Zhen
    Wu, Jun
    SENSORS, 2023, 23 (12)
  • [2] On-site calibration of a phase fraction meter by an inverse technique
    Rolnik, V.P.
    Seleghim Jr., P.
    Revista Brasileira de Ciencias Mecanicas/Journal of the Brazilian Society of Mechanical Sciences, 2002, 24 (04): : 266 - 270
  • [3] Development and evaluation of an on-site calibration technique for energy meter reference standards
    Haiba, Ahmed S.
    Halawa, Mamdouh
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (09)
  • [4] Paper-Based Analytical Device for the On-Site Detection of Nerve Agents
    Yamaguchi, Akinori
    Miyaguchi, Hajime
    Ishida, Akihiko
    Tokeshi, Manabu
    ACS APPLIED BIO MATERIALS, 2021, 4 (08): : 6512 - 6518
  • [5] A novel smartphone-based device for rapid on-site methamphetamine detection
    Liang, Sijia
    Wu, Qiaoyu
    Mao, Jikai
    Gong, Chen
    Yu, Dongdong
    Zhou, Jianguang
    MATERIALS EXPRESS, 2020, 10 (10) : 1638 - 1645
  • [6] Portable FRET-Based Biosensor Device for On-Site Lead Detection
    Lai, Wei-Qun
    Chang, Yu-Fen
    Chou, Fang-Ning
    Yang, De-Ming
    BIOSENSORS-BASEL, 2022, 12 (03):
  • [7] Development of a Portable Intelligent Electric On-site Wrench Calibration Device
    Zhao, Yinming
    Xu, Jian
    Chai, Jixin
    Hao, Qun
    2020 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL, AUTOMATION AND MECHANICAL ENGINEERING, 2020, 1626
  • [8] Portable device for on-site detection of ammonia nitrogen
    Xu, Xianbao
    Bai, Zhuangzhuang
    Wang, Tan
    INFORMATION PROCESSING IN AGRICULTURE, 2022, 9 (04): : 475 - 484
  • [9] Development and application verification of on-site calibration device for photogrammetry system
    Ou, Jia
    Xu, Tingfa
    Qu, Jiansu
    Li, Yang
    AOPC 2023:OPTIC FIBER GYRO, 2023, 12968
  • [10] Smartphone-based Electrochemical On-site Quantitative Detection Device for Nonenzyme Lactate Detection
    Zhang, Xiaotao
    Wei, Yi
    Wu, Huihuang
    Yan, Hongli
    Liu, Yiming
    Vasic, Zeljka Lucev
    Pan, Haibo
    Cifrek, Mario
    Du, Min
    Gao, Yueming
    ELECTROANALYSIS, 2022, 34 (09) : 1411 - 1421