Electrochemical measurements of uranyl ions in real nuclear wastewater using nanogold-modified electrodes

被引:0
|
作者
Han, Jingru [1 ]
Gao, Jianzhang [1 ]
Chen, Jiaqi [1 ]
Qi, Guoyan [2 ]
Gui, Yunyang [1 ]
Wang, Yuelin [1 ]
Yan, Yongde [1 ,2 ]
Ma, Fuqiu [1 ,2 ]
Chen, Qi [3 ]
Xue, Yun [1 ,2 ]
机构
[1] Harbin Engn Univ, Coll Nucl Sci & Technol, Harbin 150001, Peoples R China
[2] Harbin Engn Univ, Yantai Res Inst, Yantai 264006, Peoples R China
[3] CNNC, Sichuan Environm Protect Engn Co Ltd, Guangyuan 628000, Peoples R China
基金
中国国家自然科学基金;
关键词
Uranium; Differential pulse anodic stripping voltammetry; Sensor; Gold nanoparticles; Electrochemical determination; TRACE-ELEMENTS; URANIUM; THORIUM; SAMPLES; NANOPARTICLES; SENSOR; OXIDE;
D O I
10.1016/j.microc.2025.113340
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of uranium content is of paramount importance, extending beyond energy security and environmental protection to encompass critical roles in nuclear non-proliferation and human health preservation. In this study, a glassy carbon electrode (GCE) was modified with gold nanoparticles (AuNPs) to enhance its electrochemical performance for the detection of uranium in aqueous solutions using differential pulse adsorptive stripping voltammetry (DPASV). The incorporation of AuNPs significantly improved the electron transfer efficiency of the GCE, thereby enhancing its sensitivity for uranium detection. The effects of key parameters, including the addition of AuNPs, Nafion coating, deposition potential, deposition time, and solution pH, were systematically investigated to optimize the detection conditions. Under optimal conditions, the sensor achieved a remarkable detection limit of 0.105 mu g/L and a linear detection range of 2-10 mu g/L. The fabricated electrode demonstrates a novel and efficient approach for the rapid detection of uranium in aqueous environments. To validate its practical applicability, the sensor was tested using real nuclear wastewater samples, and the results showed excellent agreement with those obtained by inductively coupled plasma mass spectrometry (ICP-MS) and UV-vis spectrophotometry, confirming the reliability and accuracy of the proposed method.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A competitive immunoassay for electrochemical impedimetric determination of chlorpyrifos using a nanogold-modified glassy carbon electrode based on enzymatic biocatalytic precipitation
    Li Hou
    Xuanhan Zhang
    Man Kong
    Gaoyan Jiang
    Ying Sun
    Weiming Mo
    Tianran Lin
    Fanggui Ye
    Shulin Zhao
    Microchimica Acta, 2020, 187
  • [2] A competitive immunoassay for electrochemical impedimetric determination of chlorpyrifos using a nanogold-modified glassy carbon electrode based on enzymatic biocatalytic precipitation
    Hou, Li
    Zhang, Xuanhan
    Kong, Man
    Jiang, Gaoyan
    Sun, Ying
    Mo, Weiming
    Lin, Tianran
    Ye, Fanggui
    Zhao, Shulin
    MICROCHIMICA ACTA, 2020, 187 (04)
  • [3] Ionic liquid and nanogold-modified immunosensing interface for electrochemical immunoassay of hepatitis B surface antigen in human serum
    Dianping Tang
    Hang Li
    Jiayao Liao
    Microfluidics and Nanofluidics, 2009, 6 : 403 - 409
  • [4] Ionic liquid and nanogold-modified immunosensing interface for electrochemical immunoassay of hepatitis B surface antigen in human serum
    Tang, Dianping
    Li, Hang
    Liao, Jiayao
    MICROFLUIDICS AND NANOFLUIDICS, 2009, 6 (03) : 403 - 409
  • [5] Increased selectivity of electrochemical measurements using composite modified electrodes.
    Minteer, SD
    Brancato, S
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 221 : U82 - U82
  • [6] Electrochemical biosensor based on nanogold-modified poly-eriochrome black T film for BCR/ABL fusion gene assay by using hairpin LNA probe
    Lin, Liqing
    Chen, Jing
    Lin, Qihuang
    Chen, Wei
    Chen, Jinghua
    Yao, Hong
    Liu, Ailin
    Lin, Xinhua
    Chen, Yuanzhong
    TALANTA, 2010, 80 (05) : 2113 - 2119
  • [7] PAMAM/polyhedral nanogold-modified probes with DNAase catalysis for the amperometric electrochemical detection of metastasis-associated lung adenocarcinoma transcript 1
    Fei Liu
    Tao Li
    Liqun Zhang
    Guiming Xiang
    Dongneng Jiang
    Dianji Tu
    Linlin Liu
    Yi Li
    Chang Liu
    Xiaoyun Pu
    Journal of Biological Engineering, 13
  • [8] A DNA electrochemical sensor based on nanogold-modified poly-2,6-pyridinedicarboxylic acid film and detection of PAT gene fragment
    Yang, Jie
    Yang, Tao
    Feng, Yuanyuan
    Jiao, Kui
    ANALYTICAL BIOCHEMISTRY, 2007, 365 (01) : 24 - 30
  • [9] Electrochemical sensing of cadmium and lead ions at zeolite-modified electrodes: Optimization and field measurements
    Senthilkumar, S.
    Saraswathi, R.
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 141 (01): : 65 - 75
  • [10] A protein detection technique by using surface plasmon resonance (SPR) with rolling circle amplification (RCA) and nanogold-modified tags
    Huang, Yi-You
    Hsu, Hsin-Yun
    Huang, Chi-Jer Charles
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (06): : 980 - 985