Novel Chiral HPLC Method for Accurate Identification and Quantification of RS Enantiomers in Ropivacaine on Immobilized Chiral Stationary Phase: Development and Validation

被引:0
|
作者
Shaik, Althaf Hussain [1 ,2 ]
Kotanka, Ramakrishna Reddy [1 ]
Ruthala, Kiran Kumar [2 ]
Gandholi, Srinivasa Rao [3 ]
Nalla, Kirankumar [3 ]
机构
[1] REVA Univ, Dept Chem, Bangalore, Karnataka, India
[2] Univ Hyderabad, RD Lab, YMC India Pvt Ltd, Hyderabad, Pakistan
[3] Univ Hyderabad, Sch Life Sci, Dept Plant Sci, Hyderabad, India
关键词
Ropivacaine; cardiotoxicity; chiral chromatography; enantiomeric purity; method validation; QUANTITATIVE ANALYTICAL PROCEDURES; CAPILLARY-ELECTROPHORESIS; SFSTP PROPOSAL; PHARMACEUTICALS; STRATEGIES; HARMONIZATION; BUPIVACAINE; BISOPROLOL;
D O I
10.2174/0115734110321087240918112556
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Purpose Ropivacaine is a widely used local anesthetic for managing postoperative pain, particularly in procedures such as caesarean sections. While historically used as a racemate, its structural similarity to mepivacaine and bupivacaine within the pipecoloxylidide group is notable. Both enantiomers of ropivacaine exhibit similar nerve-blocking properties, but the R enantiomer is associated with increased cardiotoxicity compared to the S-Ropivacaine, like bupivacaine. This study aimed to develop and validate precise and rapid chiral chromatographic techniques for quantifying potential (RS enantiomers).Methods We used normal phase chromatography with a (3,5-dimethylphenylcarbamate) immobilized-type polysaccharide stationary phase to quantify RS enantiomers. The method followed ICH Q2(R1) guidelines, employing CHIRAL ART Amylose-SA for determining S-Ropivacaine enantiomeric purity in pharmaceutical drugs. The validation included accuracy and LOQ (limit of quantification) profiles, with measurement error assessments. Linear regression of accuracy profiles post square root transformations set acceptance limits at +/- 10%.Results The method accurately quantified RS enantiomers, adhering to ICH Q2(R1) guidelines. Validation showed high accuracy and precise LOQ profiles. Measurement error assessments confirmed reliability. Linear regression of accuracy profiles stayed within +/- 10% acceptance limits, confirming the methods suitability for determining S-Ropivacaine enantiomeric purity.Conclusion The developed chiral chromatographic method provides an effective means of quantifying the enantiomeric purity of S-Ropivacaine in pharmaceutical drugs. Its adherence to ICH Q2(R1) guidelines ensures reliability and accuracy in measurement. This method enables precise determination of S-Ropivacaine content, which is crucial for optimizing therapeutic outcomes while minimizing the risk of cardiotoxicity associated with the R enantiomer.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Development and validation of HPLC method for enantioseparation of Ibrutinib on immobilized chiral stationary phase
    Gopireddy, Raman Reddy
    Maruthapillai, Arthanareeswari
    Mahapatra, Sudarshan
    Tamilselvi, M.
    MATERIALS TODAY-PROCEEDINGS, 2022, 50 : 384 - 387
  • [2] Enantioselective separation of zopiclone on immobilized polysaccharide chiral stationary phase by HPLC: Method development and validation
    Kozlov, Oleksandr
    Zahorakova, Daniela
    Gondova, Tatana
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 190
  • [3] Development and Validation of the Chiral HPLC Method for Daclatasvir in Gradient Elution Mode on Amylose-Based Immobilized Chiral Stationary Phase
    G. Srinivasu
    K. Nagesh Kumar
    Ch. Thirupathi
    Ch. Lakshmi Narayana
    Ch. Parameswara Murthy
    Chromatographia, 2016, 79 : 1457 - 1467
  • [4] Development and Validation of the Chiral HPLC Method for Daclatasvir in Gradient Elution Mode on Amylose-Based Immobilized Chiral Stationary Phase
    Srinivasu, G.
    Kumar, K. Nagesh
    Thirupathi, Ch.
    Narayana, Ch. Lakshmi
    Murthy, Ch. Parameswara
    CHROMATOGRAPHIA, 2016, 79 (21-22) : 1457 - 1467
  • [5] Development of a chiral HPLC method for the separation and quantification of hydroxychloroquine enantiomers
    Xiong, Xisheng
    Wang, Kun
    Tang, Tao
    Fang, Jinzhi
    Chen, Yijun
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [6] Development of a chiral HPLC method for the separation and quantification of hydroxychloroquine enantiomers
    Xisheng Xiong
    Kun Wang
    Tao Tang
    Jinzhi Fang
    Yijun Chen
    Scientific Reports, 11
  • [7] Immobilized polysaccharide chiral stationary phase for HPLC .
    Amoss, CW
    Coryell, B
    Cox, GB
    Tachibana, K
    Zhang, T
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2004, 228 : U112 - U112
  • [8] Development and Validation of Stereoselective Method for the Quantification of Stereoisomers of Eliglustat Using Amylose-Based Immobilized Chiral Stationary Phase
    Srinivasu, Gunnam
    Thirupathi, Ch
    Narayanaa, Ch Lakshmi
    Murthy, C. Parameswara
    ASIAN JOURNAL OF PHARMACEUTICS, 2021, 15 (01) : 106 - 114
  • [9] Immobilized strychnine as a new chiral stationary phase for HPLC
    Sykora, David
    Vozka, Jiri
    Tesarova, Eva
    Kalikova, Kveta
    Havlik, Martin
    Matejka, Pavel
    Kral, Vladimir
    ELECTROPHORESIS, 2017, 38 (15) : 1956 - 1963
  • [10] Determination of methionine enantiomers by HPLC on the cyclofructan chiral stationary phase
    Hrobonova, Katarina
    Moravcik, Jakub
    Lehotay, Jozef
    Armstrong, Daniel W.
    ANALYTICAL METHODS, 2015, 7 (11) : 4577 - 4582