Development of A handheld pressurized ionization chamber for gamma monitoring

被引:0
|
作者
Biyik, Recep [1 ]
Alacayir, Osman [2 ]
Yalcin, Tamer [2 ]
Tuna, Tuncay [1 ,2 ]
机构
[1] Istanbul Tech Univ, Energy Inst, Istanbul, Turkiye
[2] Turkish Energy Nucl & Mineral Agcy, Nucl Energy Res Inst, Istanbul, Turkiye
关键词
ION-RECOMBINATION;
D O I
10.1016/j.radmeas.2025.107385
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this study, it is aimed to design and manufacture an ionization chamber (IC) in dimensions suitable for use in handheld radiation meter detectors. In the measurements made in the region of 0.2 mR/h and 6 R/h dose rates, it was determined that the dose current linearity was at high levels (99%) and the ionization current sensitivity was 1.7 x 10- 7 A per R/h at 10 atm (130 psig) pressure. In the saturation characteristic study of the ionization chamber at different dose rates, it was observed that the plateau region was reached at approximate to 200 V applied chamber potential values. The effect of general recombination was analyzed by using two voltage method and fitting techniques. The collection efficiency factor of the ionization chamber at low and high dose rates (between 2 mR/h-5R/h) was calculated for both techniques and found to be in agreement. The designed and fabricated ionization chamber tube has been demonstrated to satisfy the requisite criteria and is thus suitable for utilization in handheld radiation meter detectors.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] SMART IONIZATION CHAMBER FOR GAMMA-RAY MONITORING
    Drndarevic, Vujo R.
    Jevtic, Nenad J.
    Rajovic, Vladimir M.
    Stankovic, Srboljub J.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2014, 29 (03): : 190 - 198
  • [2] Development of the mini ionization chamber for high dose monitoring on line inside a gamma irradiation facility
    Rodrigues, ADA
    Vieira, JM
    Hamada, MM
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 406 - 410
  • [3] Development of a handheld device for simultaneous monitoring of fast neutrons and gamma rays
    Aryaeinejad, R
    Reber, EL
    Spencer, DF
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) : 1909 - 1913
  • [4] ENVIRONMENTAL GAMMA-RADIATION MONITORING BY MEANS OF TLD AND IONIZATION-CHAMBER
    BENKRID, M
    MEBHAH, D
    DJEFFAL, S
    ALLALOU, A
    RADIATION PROTECTION DOSIMETRY, 1992, 45 (1-4) : 77 - 80
  • [5] Development of the mini-ionization chamber for high-dose real-time monitoring inside a gamma irradiation facility
    Rodrigues, AD
    Vieira, JM
    Hamada, MM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (04) : 1098 - 1102
  • [6] Pressurized ion chamber for low energy radiation monitoring
    Prasad, KR
    Balagi, V
    Dighe, PM
    Alex, M
    Karpagam, R
    RADIATION MEASUREMENTS, 1997, 27 (04) : 593 - 598
  • [7] Development of an a grid ionization chamber
    China Institute of Atomic Energy, Beijing 102413, China
    Hedianzixue Yu Tance Jishue, 2006, 3 (331-334):
  • [8] On line high dose static position monitoring by ionization chamber detector for industrial gamma irradiators
    Rodrigues, Ary A., Jr.
    Vieira, Jose M.
    Hamada, Margarida M.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (4-5) : 665 - 668
  • [9] APPARENT ANOMALOUS BEHAVIOUR OF A MONITORING IONIZATION CHAMBER
    FOWLER, JF
    LAWREY, JM
    KITCHEN, LD
    BRITISH JOURNAL OF RADIOLOGY, 1957, 30 (359): : 616 - 616
  • [10] APPARENT ANOMALOUS BEHAVIOUR OF A MONITORING IONIZATION CHAMBER
    BUCHAN, RCT
    BRITISH JOURNAL OF RADIOLOGY, 1957, 30 (358): : 559 - 559