A comparative evaluation of 222Rn sealing materials for 226Ra analysis by gamma spectrometry

被引:0
|
作者
Seo, Han Chang [1 ]
Lee, Hyeon-Woo [1 ]
Kim, Kyeong Ho [1 ]
Kang, Jeongsoo [1 ]
Chae, Jung-Seok [1 ]
机构
[1] Korea Inst Nucl Safety, 62 Gwahak Ro, Daejeon 34142, South Korea
关键词
226 Ra analysis; Gamma spectrometry; Rn tightness; Sealing method; Secular equilibrium; RADON TIGHTNESS; RA-226; SOIL;
D O I
10.1016/j.jenvrad.2025.107673
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The accuracy of indirect measurements of 226Ra using gamma spectrometry critically depends on sealing techniques that prevent the escape of 222Rn (radon) generated within the sample. This study introduces a novel sealing method designed to overcome the limitations of conventional Rn sealing techniques. The Rn sealing performance of five sealing materials-silicone sealant, modified silicone sealant, butyl sealant, polyurethane sealant, and epoxy adhesive-was evaluated by sealing sample containers filled with Rn-containing water samples using each of the five materials, measuring Rn over time, and comparing experimentally estimated halflife of Rn for each sealed container with its physical half-life. Among the five sealing materials evaluated, the experimentally estimated half-life of Rn in samples sealed with modified silicone sealant, butyl sealant, polyurethane sealant, and epoxy adhesive, excluding silicone sealant, closely matched the physical half-life of Rn, demonstrating their reliable sealing performance. To verify the validity of the sealing method, the activity concentration of 226Ra was estimated in IAEA-434 phosphogypsum, a certified reference material, sealed with five different sealing materials. The results showed that for the four sealing materials, excluding silicone sealant, the measured values were statistically consistent with the certified value of IAEA-434, confirming the validity of the sealing method using these materials. The proposed sealing method enables accurate analytical results without requiring the complete filling of the measurement container, allows for visual inspection of the sample's filling state, and facilitates sample reuse for further analyses. These advantages make it a practical approach for the routine analysis of NORM and environmental samples.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Field Evaluation of an Encapsulated 226Ra–222Rn Source
    N. K. Sethy
    Sarjan Singh
    V. N. Jha
    Gopal Verma
    S. K. Jha
    M. S. Kulkarni
    MAPAN, 2024, 39 : 131 - 137
  • [2] Determination and differentiation of 226Ra and 222Rn by gamma-ray spectrometry in drinking water
    Kuesters, M.
    Schraven, W.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 280 (03) : 475 - 480
  • [3] Determination and differentiation of 226Ra and 222Rn by gamma-ray spectrometry in drinking water
    M. Küsters
    W. Schraven
    Journal of Radioanalytical and Nuclear Chemistry, 2009, 280 : 475 - 480
  • [4] Determination of 226Ra Activity Using Gamma Spectrometry with 226Ra-222Rn Disequilibrium
    Li, Qi
    Wang, Shilian
    Zhao, Yungang
    Liu, Shujiang
    Fan, Yuanqing
    Shi, Jianfang
    Jia, Huaimao
    Yu, Weixiang
    HEALTH PHYSICS, 2015, 109 (02): : 113 - 116
  • [5] Study of 222Rn emanation in electrodeposited sources of 226Ra with barium
    Jurado, Vargas, M.
    Fernandez de Soto, F.
    Nuclear Instruments & Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996, 368 (02):
  • [6] 226Ra and 222Rn concentrations and doses in bottled waters in Spain
    Dueñas, C
    Fernández, MC
    Carretero, J
    Liger, E
    Cañete, S
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 1999, 45 (03) : 283 - 290
  • [7] 226Ra and 222Rn concentrations and doses in bottled waters in Spain
    Duenas, C.
    Fernandez, M.C.
    Carretero, J.
    Liger, E.
    Canete, S.
    Journal of Environmental Radioactivity, 45 (03): : 283 - 290
  • [8] A study of 222Rn emanation in electrodeposited sources of 226Ra with barium
    Departamento de Física, Universidad de Extremadura, 06071 Badajoz, Spain
    Nucl Instrum Methods Phys Res Sect A, 2 (488-491):
  • [9] Ion implantation of 226Ra for a primary 222Rn emanation standard
    Mertes, Florian
    Kneip, Nina
    Heinke, Reinhard
    Kieck, Tom
    Studer, Dominik
    Weber, Felix
    Roettger, Stefan
    Roettger, Annette
    Wendt, Klaus
    Walther, Clemens
    APPLIED RADIATION AND ISOTOPES, 2022, 181
  • [10] Use of 222Rn and 226Ra to trace groundwater discharge into the Chesapeake Bay
    Hussain, N