A robust planning approach for respiratory motion in accelerated partial breast irradiation using volumetric modulated arc therapy

被引:0
|
作者
Yamauchi, Ryohei [1 ]
Tomita, Fumihiro [1 ]
Ishikura, Satoshi [1 ]
机构
[1] St Lukes Int Hosp, Dept Radiat Oncol, 9-1 Akashi Cho Chuo Ku, Tokyo 1048560, Japan
关键词
breast cancer; accelerated partial breast irradiation; intensity modulated radiation therapy; respiratory motion; RADIOTHERAPY; IMRT; OPTIMIZATION; WOMEN; VMAT;
D O I
10.1093/jrr/rraf011
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Accelerated partial breast irradiation (APBI) is an alternative treatment for early-stage breast cancer. This study aimed to evaluate the effectiveness of the virtual bolus (VB) method and robust planning against respiratory motion in volumetric modulated arc therapy (VMAT)-APBI. VMAT plans were generated with 30 Gy in 5 fractions for 16 patients. Four treatment plans were developed and compared: a standard optimization (SO) plan without robust methods, a pseudo-skin flash strategy using a 5 mm VB (with densities of 0.4 and 1.0 g/cm3, VB04 and VB10), and a robust optimization (RO) plan to minimize penalties in worst-case scenarios. The isocenter was shifted 1-5 mm in each translational direction in robust analysis, and perturbed dose calculations were performed. All dose constraints for the target in SO and VB plans were within acceptable limits, but the dose evaluation volume V95% in the RO plan was lower than in other plans (P < 0.05). The clinical target volume V95% of the RO plan was significantly higher than in VB04 and VB10 (P < 0.05). The RO plan showed the best performance for organs at risk, followed by SO and VB plans, which resulted in higher doses. The RO plan exhibited the smallest change (+/- 2%) in dose distribution due to respiratory motion. By contrast, the SO plan lacked robustness owing to absence of sufficient fluence in the air surrounding the planning target volume outside of the skin surface. The RO plan offers superior target coverage, maximum dose, and robustness compared to SO and VB methods.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] The influence of respiratory motion on dose distribution in accelerated partial breast irradiation using volumetric modulated arc therapy
    Yamauchi, Ryohei
    Mizuno, Norifumi
    Itazawa, Tomoko
    Kawamori, Jiro
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 80 : 23 - 33
  • [2] Volumetric Modulated Arc Therapy using a Rotating Couch: An Accelerated Partial Breast Irradiation Planning Study
    Kim, L.
    Smith, S.
    Yan, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S732 - S733
  • [3] Feasibility of accelerated partial breast irradiation with volumetric-modulated arc therapy in elderly and frail patients
    Olivier Riou
    Pascal Fenoglietto
    Céline Bourgier
    Olivier Lauche
    Fatiha Boulbair
    Marie Charissoux
    Angélique Ducteil
    Norbert Aillères
    Claire Lemanski
    David Azria
    Radiation Oncology, 10
  • [4] Feasibility of accelerated partial breast irradiation with volumetric-modulated arc therapy in elderly and frail patients
    Riou, Olivier
    Fenoglietto, Pascal
    Bourgier, Celine
    Lauche, Olivier
    Boulbair, Fatiha
    Charissoux, Marie
    Ducteil, Angelique
    Ailleres, Norbert
    Lemanski, Claire
    Azria, David
    RADIATION ONCOLOGY, 2015, 10
  • [5] Prone Breast Accelerated Partial Breast Irradiation Using Non-Coplanar Volumetric Arc Therapy
    Beninati, G.
    Barbiere, J.
    Godfrey, L.
    Ndlovu, A.
    MEDICAL PHYSICS, 2016, 43 (06) : 3586 - 3587
  • [6] Planning and Delivery of the Fully Dynamic Trajectory Modulated Arc Therapy: Application to Accelerated Partial Breast Irradiation
    Liang, J.
    Atwood, T.
    Fahimian, B.
    Chin, E.
    Otto, K.
    Hristov, D.
    MEDICAL PHYSICS, 2014, 41 (06) : 562 - 562
  • [7] IMPACT OF VOLUMETRIC MODULATED ARC THERAPY TECHNIQUE ON TREATMENT WITH PARTIAL BREAST IRRADIATION
    Qiu, Jian-Jian
    Chang, Zheng
    Wu, Q. Jackie
    Yoo, Sua
    Horton, Janet
    Yin, Fang-Fang
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (01): : 288 - 296
  • [8] A new technique for robust volumetric modulated arc therapy treatment planning of craniospinal irradiation
    Chamberlain, Madalyne
    Klock, Stephan
    Linsenmeier, Claudia
    di Martino, Mattia
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (06) : 602 - 602
  • [9] Accelerated Partial Breast Irradiation With Volumetric Modulated Arc Therapy: Feasibility and Early Clinical Results at the Montpellier Cancer Institute
    Fenoglietto, P.
    Rion, O.
    Boulbair, F.
    Lemanski, C.
    Charissoux, M.
    Moscardo, C. Llacer
    Ailleres, N.
    Dubois, J.
    Bourgier, C.
    Azria, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S234 - S234
  • [10] Planning strategies in volumetric modulated arc therapy for breast
    Giorgia, Nicolini
    Antonella, Fogliata
    Alessandro, Clivio
    Eugenio, Vanetti
    Luca, Cozzi
    MEDICAL PHYSICS, 2011, 38 (07) : 4025 - 4031