The effect of smart glasses combined with ultrasound on radial arterial catheterization: a randomized controlled trial

被引:0
|
作者
Wang, Yan [1 ,2 ]
Chen, Mingjing [3 ]
Zou, Ting [1 ]
Weng, Yan [2 ]
Mao, Wenjie [2 ]
Zhong, Qing [2 ]
Song, Haibo [1 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Anesthesiol, Chengdu 610041, Sichuan, Peoples R China
[2] Peoples Hosp Jianyang City, Dept Anesthesiol, Chengdu 641400, Sichuan, Peoples R China
[3] Univ Florida, Coll Publ Hlth & Hlth Profess, Dept Epidemiol, Gainesville, FL USA
来源
BMC ANESTHESIOLOGY | 2024年 / 24卷 / 01期
关键词
Radial arterial; Catheterization; Smart glasses; Ultrasound; Ultrasound-guided interventions; Clinical trial; First puncture success rate; Hand-eye coordination; Satisfaction; Complication rate; TIP POSITIONING TECHNIQUE; PEDIATRIC-PATIENTS; VASCULAR ACCESS; VENOUS ACCESS; RISK-FACTORS; CANNULATION; PALPATION; DISPLAY; ANESTHESIA; GUIDANCE;
D O I
10.1186/s12871-024-02828-8
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background The integration of smart glasses with ultrasound technology offers a novel approach to improve the efficiency of radial arterial catheterization. Few studies have investigated the effectiveness of smart glasses in enhancing procedural outcomes in a clinical setting. This study aims to assess whether smart glasses combined with ultrasound can improve the initial success rate of radial artery catheterization compared to traditional ultrasound-guided methods in adults. Methods This single-blinded, randomized controlled trial enrolled patients aged 18-70 with American Society of Anesthesiologists physical status I-III, who required radial artery catheterization as part of their procedure under general anesthesia. Patients were randomized 1:1 into the ultrasound group and the smart glasses group. Radial arterial catheterization was carried out by one of six anesthesiologists before general anesthesia. The primary endpoint was the first puncture success rate. Secondary endpoints included hand-eye coordination (measured by head rotations, probe repositioning and needle redirections), operator's satisfaction. Results A total of 222 patients were analyzed, with the smart glasses group demonstrating a higher rate of first puncture success compared to the control group (88.3% [98/111] vs. 72.1% [80/111]; P = 0.002; relative risk [RR], 1.23; 95% CI (1.07, 1.40)). Hand-eye coordination improved significantly in the smart glasses group than the control group, including: fewer number of head rotations (0 [0, 0] vs. 3 [2, 6]; P < 0.001); fewer number of ultrasound probe repositioning (0 [0, 0] vs. 0 [0, 1]; P < 0.001); fewer number of needle redirections (0 [0, 1] vs. 1 [0, 3]; P < 0.001). The proportion of positive satisfaction (81 to 100 points) in the smart glasses group was higher (89.2% [99/111] vs. 69.4% [77/111]; P < 0.001; RR, 1.29; 95% CI (1.12, 1.48)). Conclusions The use of smart glasses significantly improved the first puncture success rate, hand-eye coordination ability and operators' satisfaction in radial arterial catheterization.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Smart Glasses for Radial Arterial Catheterization in Pediatric Patients: A Randomized Clinical Trial
    Jang, Young-Eun
    Cho, Sung-Ae
    Ji, Sang-Hwan
    Kim, Eun-Hee
    Lee, Ji-Hyun
    Kim, Hee-Soo
    Kim, Jin-Tae
    ANESTHESIOLOGY, 2021, 135 (04) : 612 - 620
  • [2] Laser guidance for ultrasound-guided radial artery catheterization using smart glasses: a randomized trial
    Kim, Yoon Jung
    Jung, Chul-Woo
    Choi, Seungeun
    Kim, Youngwon
    Seo, Jeoung-Hwa
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2023, 70 (10): : 1635 - 1642
  • [3] Ultrasound guidance for radial arterial puncture: a randomized controlled trial
    Bobbia, Xavier
    Grandpierre, Romain Genre
    Claret, Pierre-Geraud
    Moreau, Alexandre
    Pommet, Stephane
    Bonnec, Jean-Marie
    Bayard, Remi Perrin
    Lefrant, Jean-Yves
    Muller, Laurent
    de La Coussaye, Jean-Emmanuel
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (05): : 810 - 815
  • [4] Subcutaneous Nitroglycerin for Radial Arterial Catheterization in Pediatric Patients A Randomized Controlled Trial
    Jang, Young-Eun
    Ji, Sang-Hwan
    Kim, Eun-Hee
    Lee, Ji-Hyun
    Kim, Hee-Soo
    Mossad, Emad B.
    Kim, Jin-Tae
    ANESTHESIOLOGY, 2020, 133 (01) : 53 - 63
  • [5] Effects of ultrasound-guided techniques for radial arterial catheterization: A meta-analysis of randomized controlled trials
    Zhao, Wenli
    Peng, Huizhen
    Li, Haiyun
    Yi, Yinping
    Ma, Yufeng
    He, Yingkun
    Zhang, Hongmei
    Li, Tianxiao
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2021, 46 : 1 - 9
  • [6] Effect of local warming for arterial catheterization in adult cardiac surgery: a randomized controlled trial
    Park, Seyeon
    Kim, Hye-Jin
    Heo, Wonjae
    Shin, Sang-Wook
    Yoon, Ji-Uk
    Byeon, Gyeong-Jo
    Lee, Jimin
    Jung, Jieun
    Kim, Hee Young
    JOURNAL OF THORACIC DISEASE, 2023, 15 (10) : 5330 - 5339
  • [7] A novel track guidance ultrasound facilitates radial arterial cannulation: A prospective randomized controlled trial
    Liu, Yongzhe
    Dong, Yuyan
    Liu, Yi
    Xu, Longhe
    JOURNAL OF VASCULAR ACCESS, 2024, 25 (05): : 1659 - 1665
  • [8] Effect of ultrasound angle for radial artery cannulation in adults: a randomized controlled trial
    Zhang, Shuang
    Liu, Tianzhu
    Liu, Yong
    Mei, Wei
    MINERVA ANESTESIOLOGICA, 2022, 88 (04) : 230 - 237
  • [9] Ultrasound Guidance Facilitates Radial Artery Catheterization A Meta-analysis With Trial Sequential Analysis of Randomized Controlled Trials
    Gu, Wan-Jie
    Wu, Xiang-Dong
    Wang, Fei
    Ma, Zheng-Liang
    Gu, Xiao-Ping
    CHEST, 2016, 149 (01) : 166 - 179
  • [10] Ultrasound-guided internal jugular vein catheterization: a randomized controlled trial
    Rando, K.
    Castelli, J.
    Pratt, J. P.
    Scavino, M.
    Rey, G.
    Rocca, M. E.
    Zunini, G.
    HEART LUNG AND VESSELS, 2014, 6 (01) : 13 - 23