Evacuation of Lisbon’s Baixa-Chiado subway station in case of fire

被引:0
|
作者
Tiago Miguel Orantos Borralho [1 ]
João Paulo Correia Rodrigues [2 ]
Cristina Calmeiro dos Santos [3 ]
机构
[1] University of Coimbra,Department of Civil Engineering
[2] University of Coimbra,Department of Civil Engineering
[3] CERIS,undefined
[4] Itecons,undefined
[5] Federal University of Minas Gerais,undefined
[6] Polytechnic Institute of Castelo Branco,undefined
来源
关键词
Evacuation modeling; Fire; Subway station; Human behavior; Emergency; Numerical simulation;
D O I
10.1007/s44150-025-00127-5
中图分类号
学科分类号
摘要
It is essential to ensure that any building has conditions for a safe evacuation of its occupants. This aspect is essential in subway stations, where evacuation has to be carried out in an upward way, and usually correspond to large structures constituting a single fire compartment. Baixa-Chiado subway station, in Lisbon, Portugal, was selected for studying the evacuation in case of fire, due to its depth, high number of passengers that frequent the station and the existing of two intersecting train lines. A calculation of evacuation time was calculated and the way of evacuation studied, in different fire scenarios, number and location of occupants. The numerical simulations used Fire Dynamics Simulator and Pathfinder softwares, the first for fire spreading and the second for evacuation analysis. The importance of smoke control system, and its rapid activation in case of fire, was highlighted by the results obtained. In situations where this did not occur, there was a significant worsening in the evacuation of the occupants. It was estimated the incapacitation of a significant number of occupants, considering the levels registered for the fractional effective dose. The station’s architectural constraints proved to be a crucial factor in the results of the study. This article highlights important results applicable to subway stations around the world.
引用
收藏
相关论文
共 37 条
  • [1] Field observation of the Baixa-Chiado Station, Lisbon Metro
    Barreto, J
    Fernandes, D
    Sousa, LR
    Cardoso, AS
    CHALLENGES FOR THE 21ST CENTURY, VOL I: INVESTIGATIONS, PLANNING AND DESIGN/UNDERGROUND SPACE USE/SUPPORT AND LINING OF TUNNELS, 1999, : 3 - 12
  • [2] Application of geomembranes to underground structures: Waterproofing of the Baixa/Chiado Subway Station in Lisbon
    Do Vale, JLM
    Scuero, AM
    Vaschetti, GL
    GEOSYNTHETICS ASIS'97 (SELECT PAPERS), 1998, : 187 - 193
  • [3] Pedestrian evacuation at the subway station under fire
    Yang, Xiao-Xia
    Dong, Hai-Rong
    Yao, Xiu-Ming
    Sun, Xu-Bin
    CHINESE PHYSICS B, 2016, 25 (04)
  • [4] Pedestrian evacuation at the subway station under fire
    杨晓霞
    董海荣
    姚秀明
    孙绪彬
    Chinese Physics B, 2016, (04) : 490 - 498
  • [5] Comparative analysis of evacuation simulation for a subway station fire
    Liu, Q. Q.
    Han, X.
    Shang, K.
    Wu, G. H.
    ISISS '2007: PROCEEDINGS OF THE INNOVATION AND SUSTAINABILITY OF STRUCTURES, VOLS 1 AND 2, 2008, : 1166 - 1174
  • [6] Study on evacuation in subway transfer station fire by STEPS
    Li Yanfeng
    Sun Xiaolong
    Feng Xiao
    Wang Chao
    Li Junmei
    2012 INTERNATIONAL SYMPOSIUM ON SAFETY SCIENCE AND TECHNOLOGY, 2012, 45 : 735 - 740
  • [7] Discuss the Application of Public Art in Subway Station - A Case on Lisbon Subway
    Xue, Juan
    Dai, Wei
    2015 2ND ASIAN PACIFIC CONFERENCE ON ENERGY, ENVIRONMENT AND SUSTAINABLE DEVELOPMENT (APEESD 2015), 2015, : 626 - 631
  • [8] Simulation on Evacuation from the Subway Station under Fire Smoke
    Zhu Wei
    Zhou Xiao-feng
    Li Zhong-wei
    PROCEEDINGS OF ISCRAM ASIA 2012 CONFERENCE ON INFORMATION SYSTEMS FOR CRISIS RESPONSE AND MANAGEMENT, 2012, : 310 - 315
  • [9] Life safety evacuation for cross interchange subway station fire
    Li Yanfeng
    Lin Xinxin
    Feng Xiao
    Wang Chao
    Li Junmei
    2012 INTERNATIONAL SYMPOSIUM ON SAFETY SCIENCE AND TECHNOLOGY, 2012, 45 : 741 - 747
  • [10] Personnel evacuation research of subway transfer station based on fire environment
    Li, Yanfeng
    Wang, Hongyi
    Wang, Chao
    Huang, Youbo
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 431 - 437