Determination of refractive error and visual acuity after implantation of multifocal or extended depth of focus lenses

被引:0
|
作者
Kaymak, Hakan [1 ,2 ]
Messerschmidt-Roth, Anke [3 ]
机构
[1] Univ Saarland, Gottfried OH Naumann Inst Epidemiol & Pravent Myop, Kirrberger Str 100, Gebaude 22, D-66424 Homburg, Germany
[2] Internatl Innovat Ophthalmochirurg GbR, Dusseldorf, Germany
[3] Philipps Univ Marburg, Klin Augenheilkunde, Marburg, Germany
来源
OPHTHALMOLOGIE | 2024年 / 121卷 / 11期
关键词
Refractive error; Patient satisfaction; Target refraction; Corrected visual acuity; Uncorrected visual acuity; INTRAOCULAR LENSES; SIZE;
D O I
10.1007/s00347-024-02131-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
There are many factors that can affect the postoperative satisfaction of patients after implantation of intraocular lenses with extended depth of focus (EDoF) and multifocal lenses (e.g., photic phenomena, postoperative complications and the presence of dry eye symptoms); however, achieving the target refraction should also be considered an important factor in the satisfaction. This article highlights the pitfalls in determining the refractive error in patients with a multifocal or EDoF lens and how uncorrected and corrected visual acuity can impact patient satisfaction.
引用
收藏
页码:930 / 941
页数:12
相关论文
共 50 条
  • [1] Assessment of Visual Acuity after Implantation of Gradient Multifocal Lenses
    Morozova T.A.
    Rozhkova G.I.
    Biomedical Engineering, 2018, 52 (4) : 257 - 262
  • [2] Functional visual acuity after implantation of diffractive extended depth-of-focus intraocular lenses using an echelett optics
    Sakisaka, Toshihiro
    Minami, Keiichiro
    Takada, Keita
    Mori, Yosai
    Miyata, Kazunori
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [3] Functional visual acuity after implantation of diffractive extended depth-of-focus intraocular lenses using an echelett optics
    Toshihiro Sakisaka
    Keiichiro Minami
    Keita Takada
    Yosai Mori
    Kazunori Miyata
    BMC Ophthalmology, 21
  • [4] Visual and Refractive Outcomes of Diffractive Trifocal Versus Hybrid Multifocal-extended Depth of Focus Intraocular Lenses
    Kim, Ui Hwan
    Choi, Tae-Hoon
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (12): : 1198 - 1207
  • [5] Near visual acuity after implantation of monofocal versus multifocal intraocular lenses
    Dick, HB
    Krist, R
    Schwenn, O
    Pfeiffer, N
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (06) : 406 - 411
  • [6] Influence of angle alpha on visual quality after implantation of extended depth of focus intraocular lenses
    Miaomiao Qin
    Min Ji
    Tianqiu Zhou
    Yurong Yuan
    Jiawei Luo
    Pengfei Li
    Ying Wang
    Xiaojuan Chen
    Wei Chen
    Huaijin Guan
    BMC Ophthalmology, 22
  • [7] Influence of angle alpha on visual quality after implantation of extended depth of focus intraocular lenses
    Qin, Miaomiao
    Ji, Min
    Zhou, Tianqiu
    Yuan, Yurong
    Luo, Jiawei
    Li, Pengfei
    Wang, Ying
    Chen, Xiaojuan
    Chen, Wei
    Guan, Huaijin
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [8] Effect of postoperative refractive error on visual acuity and patient satisfaction after implantation of the Array multifocal intraocular lens
    Lee, ES
    Lee, SY
    Jeong, SY
    Moon, YS
    Chin, HS
    Cho, SJ
    Oh, JH
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (10): : 1960 - 1965
  • [9] Refractive and Visual Outcomes After Implantation of a Secondary Sulcus Intraocular Lens with an Extended Depth of Focus
    Gundersen, Kjell Gunnar
    Potvin, Richard
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 1861 - 1869
  • [10] Optimum Refractive Target in Patients with Bilateral Implantation of Extended Depth of Focus Intraocular Lenses
    Jackson, Mitchell A.
    Edmiston, Anna M.
    Bedi, Raman
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 455 - 462