Measurements on slope parameter mapping based on dual-energy CT enterography for improving Crohn's disease diagnosis and inflammatory activity evaluation

被引:0
|
作者
Lin, Ziying [1 ]
Hong, Min [2 ]
Zhong, Hua [1 ]
Zheng, Xiaoli [1 ]
Lin, Yu [1 ]
Yang, Dan [3 ]
Zhong, Sihui [4 ]
Yue, Xin [1 ]
机构
[1] Xiamen Univ, Zhongshan Hosp, Sch Med, Dept Radiol, 201-209 Hubinnan Rd, Xiamen 361004, Fujian, Peoples R China
[2] Xiamen Univ, Xiamen Cardiovasc Hosp, Sch Med, Dept Radiol, Xiamen 361004, Fujian, Peoples R China
[3] Xiamen Hosp Tradit Chinese Med, Dept Radiol, Xiamen 361009, Fujian, Peoples R China
[4] Fujian Med Univ, Shengli Clin Med Coll, Fuzhou, Fujian, Peoples R China
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
Crohn's disease; CT enterography; Dual energy CT; Inflammatory activity; Mesenteric adipose tissue; Abdominal CT; MAGNETIC-RESONANCE ENTEROGRAPHY; SMALL-BOWEL; COMPUTED-TOMOGRAPHY; FAT;
D O I
10.1038/s41598-024-84705-5
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To explore the value of slope parameter images (SPI) derived from the dual-phase dual-energy CT enterography (DE-CTE) in the diagnosis and activity evaluation of Crohn's disease (CD). A retrospective analysis of 76 patients with CD and 53 controls who underwent dual-phase DE-CTE between January 2019 and March 2022. CD lesions were divided into non-moderate-to-severe activity (n = 108) and moderate-to-severe activity (n = 59). Virtual monoenergetic images of 40-100 keV and SPI for energy spectrum curves between 40 and 100 keV (SPI40-100) were generated. Virtual monoenergetic CT values (HU40-100keV) and the slope between 40 and 100 keV measured on SPI40-100 (SP40-100) on intestinal wall and adjacent mesenteric fat for the dual phases were collected. The performances of quantitative parameters in the diagnosis and activity assessment of CD were evaluated. The dual-phase SP40-100 and HU40-100 in the affected intestinal wall and adjacent mesenteric fat were higher than those in the control group (P < 0.001). For CD diagnosis, the area under the curve (AUC) of the arterial phase (AP) SP40-100 of mesenteric fat was the highest (AUC = 0.969, P < 0.05). The dual-phase SP40-100 and HU40-100keV of the intestinal wall and creeping fat in those with moderate-to-severe activity were significantly higher than those with non-moderate-to-severe activity (P < 0.001). For activity assessment, AP-SP40-100 of creeping fat had the highest AUC among all parameters (AUC = 0.935, P < 0.05). The measurements on SPI40-100 obtained via dual-phase DE-CTE have high value in CD diagnosis and inflammatory activity evaluation, and the AP SP40-100 of mesenteric fat has the highest diagnostic efficacy.
引用
收藏
页数:13
相关论文
共 39 条
  • [1] Prediction of pathological activity in Crohn's disease based on dual-energy CT enterography
    Zhou, Hai-fei
    Chen, Wei
    Li, Jing-qi
    Bai, Gen-ji
    Guo, Li-li
    ABDOMINAL RADIOLOGY, 2024, 49 (06) : 1829 - 1838
  • [2] Dual-energy CT enterography in evaluation of Crohn’s disease: the role of virtual monochromatic images
    Ezgi Guler
    Nalan Gulsen Unal
    Ilhan Hekimsoy
    Timur Kose
    Mustafa Harman
    Ahmet Omer Ozutemiz
    Nevra Zehra Elmas
    Japanese Journal of Radiology, 2021, 39 : 341 - 348
  • [3] Dual-energy CT enterography in evaluation of Crohn's disease: the role of virtual monochromatic images
    Guler, Ezgi
    Unal, Nalan Gulsen
    Hekimsoy, Ilhan
    Kose, Timur
    Harman, Mustafa
    Ozutemiz, Ahmet Omer
    Elmas, Nevra Zehra
    JAPANESE JOURNAL OF RADIOLOGY, 2021, 39 (04) : 341 - 348
  • [4] Establishing a machine learning model based on dual-energy CT enterography to evaluate Crohn's disease activity
    Li, Junlin
    Xie, Gang
    Tang, Wuli
    Zhang, Lingqin
    Zhang, Yue
    Zhang, Lingfeng
    Wang, Danni
    Li, Kang
    INSIGHTS INTO IMAGING, 2024, 15 (01):
  • [5] Efficiency of dual-energy computed tomography enterography in the diagnosis of Crohn’s disease
    Jinghao Chen
    Jie Zhou
    Jushun Yang
    Ruochen Cong
    Jinjie Sun
    Jing Xiao
    Jianhua Shi
    Bosheng He
    BMC Medical Imaging, 21
  • [6] Efficiency of dual-energy computed tomography enterography in the diagnosis of Crohn's disease
    Chen, Jinghao
    Zhou, Jie
    Yang, Jushun
    Cong, Ruochen
    Sun, Jinjie
    Xiao, Jing
    Shi, Jianhua
    He, Bosheng
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [7] Optimization of dual-energy CT enterography parameters for the assessment of Crohn's disease activity: a retrospective study
    Ni, Genghuan
    Su, Gang
    Shen, Haiyan
    Zhu, Peiyun
    Zhao, Hongwei
    Ao, Weiqun
    ABDOMINAL RADIOLOGY, 2024,
  • [8] Crohn's disease phenotype analysis with iodine density from dual-energy CT enterography
    Dane, Bari
    Li, Xiaochun
    Goldberg, Judith D.
    O'Donnell, Thomas
    Le, Linda
    Megibow, Alec
    ABDOMINAL RADIOLOGY, 2023, 48 (07) : 2219 - 2227
  • [9] Crohn’s disease phenotype analysis with iodine density from dual-energy CT enterography
    Bari Dane
    Xiaochun Li
    Judith D. Goldberg
    Thomas O’Donnell
    Linda Le
    Alec Megibow
    Abdominal Radiology, 2023, 48 : 2219 - 2227
  • [10] Value of dual-energy CT enterography in the analysis of pathological bowel segments in patients with Crohn's disease
    Villanueva Campos, A. M.
    Tardaguila de la Fuente, G.
    Utrera Perez, E.
    Jurado Basildo, C.
    Mera Fernandez, D.
    Martinez Rodriguez, C.
    RADIOLOGIA, 2018, 60 (03): : 223 - 229