Hexagonal Morphology Nickel Sulfide Anchored on Graphene Oxide-Modified Glassy Carbon Electrode for the Sensitive Detection of Paracetamol in Biological Samples

被引:1
|
作者
Dhamodharan, A. [1 ,2 ]
Murugan, E. [3 ]
Li, Huaxiang [1 ]
Zheng, Xiangfeng [1 ]
Gao, Yajun [1 ,2 ]
Guan, Tianzhu [1 ]
Rao, Shengqi [1 ]
Pang, Huan [2 ]
Perumal, K. [4 ]
机构
[1] Yangzhou Univ, Sch Food Sci & Engn, Yangzhou 225127, Jiangsu, Peoples R China
[2] Yangzhou Univ, Sch Chem & Chem Engn, Yangzhou 225127, Jiangsu, Peoples R China
[3] Univ Madras, Sch Chem Sci, Dept Phys Chem, Guindy Campus, Chennai 600025, Tamil Nadu, India
[4] Jeppiaar Engn Coll, Dept Phys Sci & Humanities, Chennai 600119, India
关键词
Paracetamol; Nickel sulfide; Modified electrode; Sensitivity; Selectivity; Differential pulse voltammetry; ELECTROCHEMICAL SENSOR; TERNARY NANOCOMPOSITE; RAMAN-SPECTROSCOPY; ACETAMINOPHEN; SPECTRA; ACID;
D O I
10.1007/s12678-024-00909-3
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Healthcare diagnostics and supplementary experimental research require electrochemical tools that are straightforward, inexpensive, delicate, quick, and precise. In addition to the previous reports of paracetamol sensors, we present an electrochemical sensor that customs differential pulse voltammetry (DPV) and cyclic voltammetry (CV) to determine the presence of nickel sulfide (NiS) on graphene oxide sheets (GO) (NiS@GO). Utilizing analytical methods, the composite surface morphology and structural characteristics were described. A substantial drop in overpotential was seen in the electrochemical investigation of the NiS@GO composite revised glassy carbon electrode (NiS@GO/GCE) owing to its substantial external part and high hauler agility, which demonstrated remarkable activity towards the oxidation of paracetamol (Para). Para electrochemical sensing was made more accessible by a diffusion-controlled oxidation process with an identical quantity of protons and electrons. From 3.3 mu M to 125 mu M the concentration of Para ornament linearly with the peak currents during the determination process 0.052 mu M was the Para detection limit (3 sigma/S) sensitivity of the fabricated electrode was 12.14 mu A mu M-1. In addition, the sensors demonstrated remarkable recovery with actual tablet samples over a month-long period with very little interference from common species. Commercial tablet samples demonstrate a noteworthy potential for wide-ranging applications in the electrochemical sector, with an acceptable recovery rate of 96.6 to 100.8%. An upfront, affordable quality monitoring system that can track the amount of para in tablets may be developed with the help of the suggested electrochemical sensor. Application investigations using the proposed sensor successfully detected Para in drug tabulations and biological materials.
引用
收藏
页码:182 / 195
页数:14
相关论文
共 50 条
  • [1] Simultaneous determination of paracetamol and ciprofloxacin in biological fluid samples using a glassy carbon electrode modified with graphene oxide and nickel oxide nanoparticles
    Santos, Anderson Martin
    Wong, Ademar
    Almeida, Adriana Araujo
    Fatibello-Filho, Orlando
    TALANTA, 2017, 174 : 610 - 618
  • [2] Electrochemical Detection of Paracetamol Using Graphene Oxide -Modified Glassy Carbon Electrode
    Zidan, Mohammed
    Zawawi, Ruzniza Mohd
    Erhayem, Mohamed
    Salhin, Abdussalam
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (12): : 7605 - 7613
  • [3] Enhancement in Detection of Glucose Based on a Nickel Hexacyanoferrate-Reduced Graphene Oxide-modified Glassy Carbon Electrode
    Lu, Pan
    Liu, Suqin
    Dai, Gaopeng
    Lei, Yuting
    Liang, Ying
    AUSTRALIAN JOURNAL OF CHEMISTRY, 2013, 66 (08) : 983 - 988
  • [4] Highly sensitive nonenzymatic glucose sensor based on nickel nanoparticle-attapulgite-reduced graphene oxide-modified glassy carbon electrode
    Shen, Zongxu
    Gao, Wenyu
    Li, Pei
    Wang, Xiaofang
    Zheng, Qing
    Wu, Hao
    Ma, Yuehui
    Guan, Weijun
    Wu, Songmei
    Yu, Yu
    Ding, Kejian
    TALANTA, 2016, 159 : 194 - 199
  • [5] Sensitive and Selective Detection of Imidacloprid by Graphene-Oxide-Modified Glassy Carbon Electrode
    Lei, Wu
    Han, Zhen
    Si, Weimeng
    Hao, Qingli
    Zhang, Yuehua
    Xia, Mingzhu
    Wang, Fengyun
    CHEMELECTROCHEM, 2014, 1 (06): : 1063 - 1067
  • [6] Imprinted polymer/reduced graphene oxide-modified glassy carbon electrode-based highly sensitive potentiometric sensing module for imidacloprid detection
    Kamel, Ayman H.
    Abd-Rabboh, Hisham S. M.
    MICROCHEMICAL JOURNAL, 2024, 197
  • [7] Amperometric Determination of Acetaminophen (paracetamol) Using Graphene Oxide Modified Glassy Carbon Electrode
    Alagarsamy, Periyalagan
    Settu, Ramki
    Chen, Shen-Ming
    Chen, Tse-Wei
    Hong, In-Seok
    Rao, Mettu Mallikarjuna
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (08): : 7930 - 7938
  • [8] A non-enzymatic urea sensor based on the nickel sulfide/graphene oxide modified glassy carbon electrode
    Naik, T. S. Sunil Kumar
    Saravanan, S.
    Saravana, K. N. Sri
    Pratiush, Utkarsh
    Ramamurthy, Praveen C.
    MATERIALS CHEMISTRY AND PHYSICS, 2020, 245
  • [9] Sensitive amperometric detection of omeprazole and pantoperazole at electrodeposited nickel oxide nanoparticles modified glassy carbon electrode
    Abdollah Salimi
    Zahra Enferadi
    Abdollah Noorbakhash
    Kayomars Rashidi
    Journal of Solid State Electrochemistry, 2012, 16 : 1369 - 1375
  • [10] Enhancing Dopamine Detection Using Glassy Carbon Electrode Modified with Graphene Oxide, Nickel and Gold Nanoparticles
    Hassine, Chedia Ben Ali
    Kahri, Hamza
    Barhoumi, Houcine
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (02)