Exploring the feasibility and clinical impact of ultrasound microvascular flow imaging in detecting brain injury in hyperbilirubinemia neonates

被引:0
|
作者
He, Shuang [1 ]
Wang, Meiyu [2 ]
Zhu, Man [1 ]
Zhang, Min [1 ]
He, Xueni [1 ]
Jiang, Xiang [1 ]
Tang, Shu [3 ]
Wang, Zhaoxia [1 ]
机构
[1] Chongqing Med Univ, Natl Clin Res Ctr Child Hlth & Disorders, Dept Ultrasound, Chongqing Key Lab Child Neurodev & Cognit Disorder, Lianglukou St, Chongqing, Peoples R China
[2] Shulan Jinan Hosp, Dept Pediat, Jinan, Peoples R China
[3] Chongqing Univ Posts & Telecommun, Key Lab Comp Network & Commun Technol, Chongqing, Peoples R China
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
Cranial Ultrasound; MV-Flow; Hyperbilirubinemia; Neonatal; BILIRUBIN; TERM;
D O I
10.1038/s41598-025-88007-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Neonatal hyperbilirubinemia is a prevalent condition during the neonatal period, and in severe instances, it can result in brain damage accompanied by irreversible neurological consequences. Therefore, early detection and intervention are paramount. This research aimed to detect early-stage brain damage resulting from neonatal hyperbilirubinemia through the application of two-dimensional cranial ultrasound and microvascular blood flow (MV-Flow) imaging techniques. Clinical data, along with gray-scale and microvascular ultrasound images of the basal ganglia, were collected from 85 neonates (hyperbilirubinemia group vs. non-hyperbilirubinemia group: 51 vs. 34). The Globus Pallidus to Putamen (G/P) ratio and the vascular index (VIMV) were calculated. A comparative analysis of clinical and ultrasonographic data between the groups was conducted. The hyperbilirubinemia group had higher mean G/P ratios (1.39 +/- 0.49 vs. 1.16 +/- 0.12, P < 0.05) and lower VIMV, which was negatively correlated with TSB levels (coronal: r = -0.419, P < 0.05; parasagittal: r = -0.448, P < 0.05). Cranial gray-scale ultrasound demonstrates altered gray values in the basal ganglia region, and the MV-Flow technique reveals and quantifies the microvascular structure of this region. These methods may serve as potential biological markers for the early assessment of bilirubin-induced brain damage.
引用
收藏
页数:12
相关论文
共 18 条
  • [1] Microvessel ultrasound of neonatal brain parenchyma: feasibility, reproducibility, and normal imaging features by superb microvascular imaging (SMI)
    Goeral, Katharina
    Hojreh, Azadeh
    Kasprian, Gregor
    Klebermass-Schrehof, Katrin
    Weber, Michael
    Mitter, Christian
    Berger, Angelika
    Prayer, Daniela
    Brugger, Peter C.
    Vergesslich-Rothschild, Klara
    Patsch, Janina M.
    EUROPEAN RADIOLOGY, 2019, 29 (04) : 2127 - 2136
  • [2] Microvessel ultrasound of neonatal brain parenchyma: feasibility, reproducibility, and normal imaging features by superb microvascular imaging (SMI)
    Katharina Goeral
    Azadeh Hojreh
    Gregor Kasprian
    Katrin Klebermass-Schrehof
    Michael Weber
    Christian Mitter
    Angelika Berger
    Daniela Prayer
    Peter C. Brugger
    Klara Vergesslich-Rothschild
    Janina M. Patsch
    European Radiology, 2019, 29 : 2127 - 2136
  • [3] Computerized Tomography vs Ultrasound Imaging for Detecting Hypoxic-Ischemic Brain Injury
    Karfunkle, Benjamin
    Kotini-Shah, Pavitra
    Gordon, Richard
    Li, Jing
    Granado, Misha
    Doshi, Pratik B.
    Wang, Henry
    Hoek, Terry L. Vanden
    CIRCULATION, 2021, 144
  • [4] Utility of carotid ultrasound using microvascular flow imaging for detecting in-stent plaque protrusion after carotid artery stenting
    Hagiwara, Yuta
    Ito, Hidemichi
    Fukano, Takayuki
    Shimizu, Takahiro
    Uchida, Masashi
    Yamano, Yoshihisa
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2025, 251
  • [5] Head Ultrasound Resistive Indices Are Associated With Brain Injury on Diffusion Tensor Imaging Magnetic Resonance Imaging in Neonates With Hypoxic-Ischemic Encephalopathy
    Snyder, Elizabeth J.
    Perin, Jamie
    Chavez-Valdez, Raul
    Northington, Frances J.
    Lee, Jennifer K.
    Tekes, Aylin
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (05) : 687 - 691
  • [6] Clinical application of intraoperative ultrasound superb microvascular imaging in brain tumors resections: contributing to the achievement of total tumoral resection
    Cai, Siman
    Xing, Hao
    Wang, Yuekun
    Wang, Yu
    Ma, Wenbin
    Jiang, Yuxin
    Li, Jianchu
    Wang, Hongyan
    BMC MEDICAL IMAGING, 2024, 24 (01):
  • [7] Assessment of ultrasound as a diagnostic modality for detecting potentially unstable cervical spine fractures in pediatric severe traumatic brain injury: A feasibility study
    Agrawal, Deepak
    Sinha, Tej Prakash
    Bhoi, Sanjeev
    JOURNAL OF PEDIATRIC NEUROSCIENCES, 2015, 10 (02) : 119 - 122
  • [8] USE OF HIGH RESOLUTION DIFFUSION TENSOR IMAGING IN ACUTE TRAUMATIC BRAIN INJURY: FEASIBILITY AND INITIAL CLINICAL RESULTS
    Newcombe, V.
    Correia, M.
    Veenith, F.
    Carter, E.
    Outtrim, J.
    Coles, J.
    Hutchinson, P.
    Williams, G.
    Menon, D.
    INTENSIVE CARE MEDICINE, 2012, 38 : S275 - S275
  • [9] Brain injury in the international multicenter randomized SafeBoosC phase II feasibility trial: cranial ultrasound and magnetic resonance imaging assessments
    Plomgaard, Anne M.
    Hagmann, Cornelia
    Alderliesten, Thomas
    Austin, Topun
    van Bel, Frank
    Claris, Olivier
    Dempsey, Eugene
    Franz, Axel
    Fumagalli, Monica
    Gluud, Christian
    Greisen, Gorm
    Hyttel-Sorensen, Simon
    Lemmers, Petra
    Pellicer, Adelina
    Pichler, Gerhard
    Benders, Manon
    PEDIATRIC RESEARCH, 2016, 79 (03) : 466 - 472
  • [10] Exploring the feasibility of ultrasound liver imaging reporting and data system (US LI-RADS) and visualisation score in clinical application
    Seng, Dorothy
    Low, Albert
    Afif, Azizah
    Lau, Denise
    Simin, Teo
    Chang, Pei-Yuan
    JOURNAL OF HEPATOLOGY, 2024, 80 : S637 - S637