Design research on a smart infusion device to reduce medical workload and enhance patient safety

被引:0
|
作者
Mu, Bo [1 ,3 ]
Wang, Yilun [1 ]
Liu, Xunchen [2 ]
Bebit, Mohammad Puad [3 ]
Chen, Mingzhang [2 ]
Wu, Hailin [2 ]
Zhang, Wei [1 ]
Wang, Lanxin [1 ]
Fang, Yuan [4 ]
Dong, Kang [2 ]
机构
[1] Wuhan Inst Technol, Sch Art & Design, Wuhan 430205, Peoples R China
[2] Wuhan Univ Technol, Sch Automot Engn, Wuhan 430070, Peoples R China
[3] Univ Malaysia Sabah, Acad Arts & Creat Technol, Kota Kinabalu 88400, Malaysia
[4] South Cent Univ Nationalities, Coll Chem & Mat Sci, Minist Educ, Key Lab Catalysis & Energy Mat Chem, Wuhan 430074, Peoples R China
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
Smart infusion device; Automatic medication replacement; Healthcare automation; Medical device innovation; WIRELESS SENSOR NETWORKS; HEALTH-CARE; TECHNOLOGIES; THERAPY;
D O I
10.1038/s41598-025-93911-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In traditional infusion processes, issues such as untimely medication replacement and patients' difficulty in continuously monitoring their medication levels are prevalent. This study presents the design of a smart infusion automatic medication replacement device aimed at automating infusion management through three key modules: high-precision liquid level monitoring, automated medication replacement, and a smart control system. By monitoring liquid levels in real time, the system eliminates the need for patients to constantly check their medication levels, accurately controlling the amount of medication dispensed and transmitting monitoring signals within safe thresholds. The rotational medication replacement mechanism stores and precisely replaces medicine bottles, optimizing usage and minimizing waste. Automated settings for liquid level monitoring and the plug-and-push system replace the need for manual assessment of medication completion and input quality, ensuring consistent dosage and high-quality delivery. The rotational mechanism also reduces the time needed for refilling and decreases the labor intensity for healthcare providers. A stabilization and calibration mechanism ensures bottles remain centered, preventing issues with internal pressure changes and loosening of the piercing tool. By replacing repetitive manual adjustments with automated processes, healthcare professionals can focus more on patient care rather than the cumbersome medication replacement procedures. The smart infusion automatic medication replacement device enhances the quality of infusion therapy for patients and alleviates the repetitive workload of medical staff.
引用
收藏
页数:27
相关论文
共 50 条
  • [1] Design of low cost smart infusion device
    Saputra, Yohanes David
    Purnamaningsih, Retno Wigajatri
    INTERNATIONAL SEMINAR ON PHOTONICS, OPTICS, AND ITS APPLICATIONS (ISPHOA 2014), 2015, 9444
  • [2] The Role of "Smart" Infusion Pumps in Patient Safety
    Scanlon, Matthew
    PEDIATRIC CLINICS OF NORTH AMERICA, 2012, 59 (06) : 1257 - +
  • [3] Implementing Smart Pumps to Enhance Patient Safety
    Davis, Sondra
    Blanchard, Corliss
    Lewis, Jevon
    HOSPITAL PHARMACY, 2019, 54 (04) : 217 - 219
  • [4] Maximizing Smart Pump Technology to Enhance Patient Safety
    Makic, Mary Beth Flynn
    CLINICAL NURSE SPECIALIST, 2015, 29 (04) : 195 - 197
  • [5] Impact of Design on Medical Device Safety
    Miclaus, Teodora
    Valla, Vasiliki
    Koukoura, Angeliki
    Nielsen, Anne Ahlmann
    Dahlerup, Benedicte
    Tsianos, Georgios-Ioannis
    Vassiliadis, Efstathios
    THERAPEUTIC INNOVATION & REGULATORY SCIENCE, 2020, 54 (04) : 839 - 849
  • [6] Impact of Design on Medical Device Safety
    Teodora Miclăuş
    Vasiliki Valla
    Angeliki Koukoura
    Anne Ahlmann Nielsen
    Benedicte Dahlerup
    Georgios-Ioannis Tsianos
    Efstathios Vassiliadis
    Therapeutic Innovation & Regulatory Science, 2020, 54 : 839 - 849
  • [7] Intelligent Infusion Technologies Integration of a Smart System to Enhance Patient Care
    Agius, Christine R.
    JOURNAL OF INFUSION NURSING, 2012, 35 (06) : 364 - 368
  • [8] Quality Improvement and Patient Safety: Living With "Smart" Infusion Devices
    Duffett, Mark
    CANADIAN JOURNAL OF HOSPITAL PHARMACY, 2005, 58 : 30 - 31
  • [9] Redesigned Computerized Prescribing System to Reduce Physicians' Workload and Improve Patient Safety
    Seto, Ryoma
    Wakabayashi, Susumu
    Hosaka, Ryosuke
    MEDINFO 2013: PROCEEDINGS OF THE 14TH WORLD CONGRESS ON MEDICAL AND HEALTH INFORMATICS, PTS 1 AND 2, 2013, 192 : 1225 - 1225
  • [10] Patient safety in medical technology research
    Doessel, O.
    BUNDESGESUNDHEITSBLATT-GESUNDHEITSFORSCHUNG-GESUNDHEITSSCHUTZ, 2009, 52 (06) : 579 - 583