Accuracy of polyether and vinylpolysiloxane impressions when using different types of 3D-printed impression trays - an in vitro study

被引:1
|
作者
Rues, Stefan [1 ]
Depre, David [1 ]
Stober, Thomas [1 ]
Rammelsberg, Peter [1 ]
Zenthoefer, Andreas [1 ]
机构
[1] Heidelberg Univ, Dept Prosthodont, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
关键词
Open implant impression; Accuracy; 3D-printed trays; Polyether; Polyvinylsiloxane; Peel bond strength;
D O I
10.1007/s00784-024-05962-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To investigate dimensional accuracy of polyether (PE) and vinylpolysiloxane (VPS) impressions taken with manually fabricated and 3D-printed trays. Materials and methods To evaluate impression accuracy, highly precise digital data of a metallic lower jaw model with prepared teeth (regions 34 and 36), an implant (region 47) and three precision balls placed occlusally along the dental arch served as reference. PE (Impregum, 3M Oral Care) and VPS (Aquasil, Dentsply Sirona) impressions (n = 10/group) were taken with trays fabricated using different materials and manufacturing techniques (FDM: filament deposition modeling, material: Arfona Tray, Arfona; printer: Pro2, Raise3D; DLP: digital light processing, material: V-Print Tray, VOCO, printer: Max, Asiga; MPR: manual processing with light-curing plates, material: LC Tray, M & uuml;ller-Omicron) including an open implant impression. Scans of resulting stone models were compared with the reference situation. Global distance and angular deviations as well as local trueness and precision for abutment teeth and scan abutment were computed. Possible statistical effects were analyzed using ANOVA. Results Clinically acceptable global accuracy was found (all mean absolute distance changes < 100 mu m) and local accuracy for single abutments was excellent. All factors (abutment type, impression material, tray material) affected global accuracy (p < 0.05). In particular with PE impressions, MPR trays led to the best accuracies, both in horizontal and vertical direction. Conclusions Within the limitations of this in vitro study, impression accuracy was high in use of both polyether and vinylpolysiloxane combined with different 3D-printed and customized trays making them recommendable for at least impressions for smaller fixed dental prostheses. Manually fabricated trays were overall still the best choice if utmost precision is required. Clinical relevance Based on the results of this study, use of innovative CAD-CAM fabrication of individual impression trays fulfills the perquisites to be a viable option for impression making. In the sense of translational research, performance should be proved in a clinical setting.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Accuracy of polyether and vinylpolysiloxane impressions when using different types of 3D-printed impression trays: comment
    Hinpetch Daungsupawong
    Viroj Wiwanitkit
    Clinical Oral Investigations, 29 (5)
  • [2] Accuracy of Different Elastomeric Impression Materials Using Dual Arch Impression Trays: An In Vitro Study
    Duseja, Sareen
    Shah, Dipti
    Vaishnav, Kalpesh
    Duseja, Shilpa
    Kumar, Santosh
    Desai, Khushboo
    ADVANCES IN HUMAN BIOLOGY, 2014, 4 (02) : 3 - 8
  • [3] Disposable plastic trays and their effect on polyether and vinyl polysiloxane impression accuracy—an in vitro study
    Stefan Rues
    Thomas Stober
    Thomas Bargum
    Peter Rammelsberg
    Andreas Zenthöfer
    Clinical Oral Investigations, 2021, 25 : 1475 - 1484
  • [4] Chairside 3-D printed impression trays: a new approach to increase the accuracy of conventional implant impression taking? An in vitro study
    Alexander Schmidt
    Cara Berschin
    Bernd Wöstmann
    Maximiliane Amelie Schlenz
    International Journal of Implant Dentistry, 9
  • [5] Chairside 3-D printed impression trays: a new approach to increase the accuracy of conventional implant impression taking? An in vitro study
    Schmidt, Alexander
    Berschin, Cara
    Woestmann, Bernd
    Schlenz, Maximiliane Amelie
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2023, 9 (01)
  • [6] Accuracy of bracket position using thermoplastic and 3D-printed indirect bonding trays
    Shin, Seol-Hee
    Lee, Kee-Joon
    Kim, Su-Jung
    Yu, Hyung-Seog
    Kim, Kwang-Mahn
    Hwang, Chung-Ju
    Cha, Jung-Yul
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2021, 24 (02) : 133 - 145
  • [7] Disposable plastic trays and their effect on polyether and vinyl polysiloxane impression accuracy-an in vitro study
    Rues, Stefan
    Stober, Thomas
    Bargum, Thomas
    Rammelsberg, Peter
    Zenthoefer, Andreas
    CLINICAL ORAL INVESTIGATIONS, 2021, 25 (03) : 1475 - 1484
  • [8] Study of the interocclusal distortion in impressions taken with different types of closed-mouth trays and two types of impression materials
    Manes-Ferrer, Jose-Felix
    Selva-Otaolaurruchi, Eduardo-Jose
    Parra-Arenos, Carmina
    Selfa-Bas, Isabel
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2010, 15 (01): : E79 - E84
  • [9] Transfer accuracy of 3D-printed trays for indirect bonding o orthodontic brackets: A clinical study
    Bachour, Petra C.
    Klabunde, Robert
    Grunheid, Thorsten
    ANGLE ORTHODONTIST, 2022, 92 (03) : 372 - 379
  • [10] Accuracy and feasibility of 3D-printed custom open trays for impressions of multiple implants: A self-controlled clinical trial br
    Yang, Xulan
    Liu, Yanping
    Li, Yuan
    Zhao, Yijiao
    Di, Ping
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (03): : 396 - 403