EchoPhaseFormer: A Transformer Based Echo Phase Detection and Analysis in 2D Echocardiography

被引:0
|
作者
Gajraj Singh [1 ]
Anand D. Darji [2 ]
Jignesh N. Sarvaiya [1 ]
Suprva Patnaik [1 ]
机构
[1] Department of Electronics Engineering,Department of Electronics and Telecommunication Engineering, Ramrao Adik Institute of Technology
[2] Sardar Vallabhbhai National Institute of Technology,School of Electronics Engineering
[3] D.Y. Patil Deemed to be University,undefined
[4] Kalinga Institute of Industrial Engineering,undefined
关键词
Echocardiography; Diastole and systole phase; Transformer; Echo phase detection; Average absolute frame distance);
D O I
10.1007/s42979-024-03249-7
中图分类号
学科分类号
摘要
The accurate cardiac function analysis (i.e., ventricle/stroke volume and ejection fraction measurement) in 2D echocardiography is challenging because of the low-resolution nature of echo sequence and motion in cardiac structure. In an echo sequence, the cardiac function analysis is a sequential process: identification of end-diastole (ED) and end-systole (ES) frames (echo phase detection) followed by the left ventricle ejection fraction (LVEF) prediction. To precisely describe cardiac function, proper attention must be given to spatial and temporal information and their interaction. Several deep learning (i.e., convolution neural networks, recurrent neural networks, and transformer) techniques have recently been introduced but have largely ignored the spatial and temporal information interaction. To address this issue, this study introduces EchoPhaseFormer, a transformer-based solution for echo phase detection (EPD) and LVEF prediction. A 3D convolution stemming is used to get the 3D patches from the echo sequence to retain the temporal information. The EchoPhaseFormer has an echo phase former block consisting of a conditional positional encoder and a phase self-attention module that ensures the spatial–temporal information extraction and their interaction. The EchoPhaseFormer outperformed the state-of-the-art architectures for both tasks on the EchoNet dataset. We obtain an average absolute frame distance of 1.01 for ED frames and 1.04 for ES frames for EPD, respectively. Regarding LVEF prediction, we obtain a mean absolute error of 4.77, a root mean square error of 6.14, and an R2 score of 0.81.
引用
收藏
相关论文
共 50 条
  • [1] IS DOPPLER ECHOCARDIOGRAPHY BETTER THAN 2D ECHO IN THE DETECTION OF PERICARDIAL TAMPONADE
    BOMMER, WJ
    EVERHART, R
    SMITH, D
    LAI, D
    FEHRENBACHER, G
    LOCK, R
    BENVENUTI, T
    REBECK, K
    VERA, Z
    CLINICAL RESEARCH, 1987, 35 (01): : A101 - A101
  • [2] Preprocessing and frame level classification framework for cardiac phase detection in 2D echocardiography
    Singh, Gajraj
    Darji, Anand D.
    Sarvaiya, Jignesh N.
    Patnaik, Suprva
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2025, 107
  • [3] Simultaneous Analysis of 2D Echo Views for Left Atrial Segmentation and Disease Detection
    Allan, Gregory
    Nouranian, Saman
    Tsang, Teresa
    Seitel, Alexander
    Mirian, Maryam
    Jue, John
    Hawley, Dale
    Fleming, Sarah
    Gin, Ken
    Swift, Jody
    Rohling, Robert
    Abolmaesumi, Purang
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (01) : 40 - 50
  • [4] A deep learning phase-based solution in 2D echocardiography motion estimation
    Khoubani, Sahar
    Moradi, Mohammad Hassan
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (04) : 1691 - 1703
  • [5] 2D photon echo
    Noriaki Horiuchi
    Nature Photonics, 2016, 10 (12) : 751 - 751
  • [6] DETECTION OF PROXIMAL LEFT ANTERIOR DESCENDING CORONARY-ARTERY OBSTRUCTION WITH TWO-DIMENSIONAL ECHOCARDIOGRAPHY (2D ECHO)
    RINK, LD
    FEIGENBAUM, H
    MARSHALL, JE
    GODLEY, RW
    PHILLIPS, JF
    DILLON, JC
    WEYMAN, AE
    CIRCULATION, 1980, 62 (04) : 33 - 33
  • [7] Object detection based on 2D canonical correlation analysis
    Zhang, Guofeng
    Zhou, Weida
    Ren, Weihua
    Liu, Shuang
    MIPPR 2007: PATTERN RECOGNITION AND COMPUTER VISION, 2007, 6788
  • [8] 2D and 3D Echocardiography to Assess Reverse Remodeling after CRT: What is its Real Application? Did 3D Echocardiography Improve 2D Echo Evaluation?
    Gimenes, Vera Marcia
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2011, 97 (03) : 184 - 185
  • [9] 2D ECHO DEFINITION OF ENDOCARDIUM
    MEISTER, SG
    CASEY, PR
    JACOBS, L
    BARRETT, MJ
    CLINICAL RESEARCH, 1980, 28 (03): : A616 - A616
  • [10] 2D ECHO DEFINITION OF ENDOCARDIUM
    MEISTER, SG
    CASEY, PR
    JACOBS, L
    BARRETT, MJ
    CIRCULATION, 1980, 62 (04) : 132 - 132