Analysis of Shielding Effectiveness of a Cavity with Internal Dielectric Plate and Apertures

被引:0
|
作者
Guo, Laigong [1 ]
Shi, Xinkang [1 ]
Li, Xiaolong [1 ]
Ma, Long [2 ]
Guo, Changna [2 ]
机构
[1] Anhui Univ Sci & Technol, Coll Elect & Informat Engn, Huainan 232001, Peoples R China
[2] China Coal Technol & Engn Grp, State Key Lab Coal Mine Safety Technol, Shenyang Res Inst, Shenfu Demonstrat Zone, Fushun 113122, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2025年 / 15卷 / 05期
关键词
cavity shielding; transmission line; BLT equation; shielding effectiveness; dielectric plate; ENCLOSURE; MODEL;
D O I
10.3390/app15052460
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Focusing on the shielding effectiveness of a single-layer shielded cavity, especially the impact of aperture shape, aperture quantity, internal dielectric plate, and other factors on shielding effectiveness, an equivalent circuit model and BLT equation of shielding effectiveness for a single-layer shielded cavity under plane-wave irradiation were constructed by applying transmission line theory, Robinson's algorithm, and electromagnetic topology theory. The shielding effectiveness of the cavity with an internal dielectric plate subjected to 0 to 1 GHz electromagnetic waves was calculated. The influence of circular and rectangular aperture arrays, the thickness of the dielectric plate, and the position change of the dielectric plate on the electric field shielding effectiveness of the cavity were analyzed. HFSS was used for simulation experiments. The research indicates that increasing the number of apertures can effectively enhance the shielding effectiveness while keeping the total area of the apertures constant. In addition, the insertion of a dielectric plate inside the cavity, especially near the resonant frequency, significantly enhanced the shielding effectiveness due to the absorption of incident electromagnetic waves by the dielectric plate. As the thickness of the dielectric plate was increased, the resonant frequency of the cavity gradually decreased; the shielding effectiveness was improved near the resonant frequency. Placing the dielectric plate at the lower end of the cavity is preferred, as it significantly improves the shielding effectiveness.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Hybrid model to evaluating shielding effectiveness of cavity with apertures
    Zhang, Xu-Feng
    Li, Ying
    Ni, Gu-Yan
    Luo, Jian-Shu
    Dianbo Kexue Xuebao/Chinese Journal of Radio Science, 2011, 26 (01): : 24 - 29
  • [2] Simplified Model of Shielding Effectiveness of a Cavity with Apertures on Different Sides
    Hao, Cui
    Li, Denghua
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2014, 56 (02) : 335 - 342
  • [3] Analyzing of the Near-Field Shielding Effectiveness of the Cylindrical Cavity with Apertures
    Fan, Jieqing
    Hao, Jianhong
    Song, Zixian
    Liu, Xuefen
    PROGRESS IN MECHATRONICS AND INFORMATION TECHNOLOGY, PTS 1 AND 2, 2014, 462-463 : 573 - +
  • [4] Analysis of shielding effectiveness of rectangular cavity with apertures to ESD radiated field by transmission line method
    Wang, Liuping
    2007 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY: WORKSHOP AND TUTORIAL NOTES, VOLS 1-3, 2007, : 922 - 925
  • [5] FDTD analysis for shielding effect of metal plate with apertures
    Lu, Fei-Yan
    Sha, Fei
    Beifang Jiaotong Daxue Xuebao/Journal of Northern Jiaotong University, 2003, 27 (03):
  • [6] Low Frequency Magnetic Shielding Effectiveness of a Conducting Plate With Periodic Apertures
    Bai, Wanxin
    Ning, Feng
    Yang, Xiaochen
    Jiao, Chongqing
    Chen, Longlong
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2021, 63 (01) : 30 - 37
  • [7] Analysis for shielding effect of metal plate with apertures with FDTD
    Lu, FY
    Sha, F
    2002 3RD INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, 2002, : 739 - 743
  • [8] Shielding effectiveness of an enclosure with apertures
    Gu, CH
    Li, SF
    IEEE 2005 International Symposium on Microwave, Antenna, Propagation and EMC Technologies for Wireless Communications Proceedings, Vols 1 and 2, 2005, : 614 - 618
  • [9] Calculation and Analysis of Shielding Effectiveness of the Rectangular Enclosure with Apertures
    Wang, Chuan-Chuan
    Zhu, Chang-Qing
    Zhou, Xing
    Gu, Zhi-Feng
    APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY JOURNAL, 2013, 28 (06): : 535 - 545
  • [10] Analysis for shielding effectiveness of infinite metal plate with arrayed apertures using semi-analytical FDTD
    Bao, YF
    Lu, YH
    ASIA-PACIFIC CONFERENCE ON ENVIRONMENTAL ELECTROMAGNETICS, CEEM'2003, PROCEEDINGS, 2003, : 56 - 59