Periodic detection and disinfection maintenance of dental unit waterlines in dental simulation head model laboratories

被引:0
|
作者
Li, Biyao [1 ]
Hu, Yuya [1 ]
Wang, Yiqi [1 ]
Zhang, Chengqi [1 ]
Wang, Zimo [1 ]
Peng, Xujie [1 ]
Feng, Jianying [1 ,2 ]
机构
[1] Zhejiang Chinese Med Univ, Sch Stomatol, Hangzhou, Zhejiang, Peoples R China
[2] Zhejiang Chinese Med Univ, Sch Hosp Stomatol, Dept Stomatol, Hangzhou, Zhejiang, Peoples R China
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
Dental simulation head model laboratory; Dental unit waterlines; Microbial contamination; Organochlorine disinfectant; Chlorine dioxide; High-throughput sequencing; CONTAMINATION; DIVERSITY; BIOFILMS; EFFICACY; QUALITY;
D O I
10.1038/s41598-025-89010-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Dental simulation head model laboratories are crucial for clinical simulation training for stomatological students, yet the maintenance of their dental unit waterlines (DUWLs) has been overlooked. This study investigated water contamination in DUWLs within these laboratories and proposed solutions. Water samples were collected from 12 dental chairs in three laboratories at three time points: the beginning, middle, and end of the semester. At the start of the semester, severe contamination was observed, with colony counts of 11,586\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\:\pm\:$$\end{document}1715 CFU/ml for high-speed handpieces and 5375\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\:\pm\:$$\end{document}874 CFU/ml for three ways syringes. As the semester progressed, colony counts gradually decreased but remained above clinical thresholds. Both 20 mg/L organochlorine disinfectant and 20 mg/L chlorine dioxide were effective in reducing bacterial contamination below standard ranges three days post-disinfection. Microbial diversity analysis revealed Proteobacteria and Bacteroidota as the dominant bacterial phyla, with Ascomycota as the dominant fungal phylum. Potentially pathogenic bacteria such as Pseudomonas, Burkholderia-Caballeronia-Paraburkholderia, Ralstonia, Mycobacterium, Legionella, Paenibacillus, Streptomyces, Acinetobacter, and Prevotella, as well as fungi like Fusarium and Penicillium, were detected. Therefore, urgent attention is needed to address DUWL contamination in dental laboratories, and it is recommended to disinfect DUWLs using either 20 mg/L organochlorine disinfectant or 20 mg/L chlorine dioxide every three days.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] An update of dental unit waterlines disinfection
    Lee, Shiuan-Shinn
    Yang, Li-Chiu
    Chang, Yu-Chao
    JOURNAL OF DENTAL SCIENCES, 2022, 17 (04) : 1831 - 1832
  • [2] Dental Unit Waterlines: Disinfection and Management
    Samaranayake, Lakshman
    Fakhruddin, Kausar
    Sobon, Norbert
    Osathanon, Thanaphum
    INTERNATIONAL DENTAL JOURNAL, 2024, 74 : S437 - S445
  • [3] Dental unit waterlines: Biofilms, disinfection and recurrence
    Meiller, TF
    DePaola, LG
    Kelley, JI
    Baqui, AAMA
    Turng, BF
    Falkler, WA
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1999, 130 (01): : 65 - 72
  • [4] The effect of Sterilex UltraR for disinfection of dental unit waterlines
    Larsen, T
    Fiehn, NE
    INTERNATIONAL DENTAL JOURNAL, 2003, 53 (04) : 249 - 254
  • [5] Biofilms of dental unit waterlines: Antimicrobials for disinfection and recurrence.
    Meiller, TF
    Kelley, JI
    Depaola, LG
    Baqui, AAMA
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 3369 - 3369
  • [6] Disinfection methods of dental unit waterlines contamination: a systematic review
    Wu, Mengting
    Shi, Zhiwei
    Yu, Xuefen
    Xu, Yuedan
    Jin, Xinyang
    Zhang, Ling
    Fu, Baiping
    JOURNAL OF MEDICAL MICROBIOLOGY, 2022, 71 (06)
  • [7] Bacterial contamination of new dental unit waterlines and efficacy of shock disinfection
    Baudet, Alexandre
    Lizon, Julie
    Lozniewski, Alain
    Florentin, Arnaud
    Mortier, Eric
    BMC MICROBIOLOGY, 2024, 24 (01):
  • [8] Biofilm and dental unit waterlines
    Szymanska, J
    ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 2003, 10 (02) : 151 - 157
  • [9] Cleaning dental unit waterlines
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2004, 135 (01): : 46 - 47
  • [10] Effect of Different Disinfection Protocols on Microbial and Biofilm Contamination of Dental Unit Waterlines in Community Dental Practices
    Dallolio, Laura
    Scuderi, Amalia
    Rini, Maria S.
    Valente, Sabrina
    Farruggia, Patrizia
    Sabattini, Maria A. Bucci
    Pasquinelli, Gianandrea
    Acacci, Anna
    Roncarati, Greta
    Leoni, Erica
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2014, 11 (02) : 2064 - 2076