Securing X-Ray Images Into Cover Images Using Hybrid EBS Steganography With Five-Layer Cryptography

被引:0
|
作者
Sharma, Divya [1 ]
Prabha, Chander [1 ]
Hassan, Md Mehedi [2 ]
Abdulla, Shahab [3 ]
Bairagi, Anupam Kumar [2 ]
Alshathri, Samah [4 ]
El-Shafai, Walid [5 ,6 ]
机构
[1] Chitkara Univ, Inst Engn & Technol, Rajpura 140401, Punjab, India
[2] Khulna Univ, Comp Sci & Engn Discipline, Khulna 9208, Bangladesh
[3] Univ Southern Queensland, UniSQ Coll, Toowoomba, Qld 4305, Australia
[4] Princess Nourah Bint AbdulRahman Univ, Coll Comp & Informat Sci, Dept Informat Technol, POB 84428, Riyadh, Saudi Arabia
[5] Prince Sultan Univ, Comp Sci Dept, Secur Engn Lab, Riyadh 11586, Saudi Arabia
[6] Menoufia Univ, Fac Elect Engn, Dept Elect & Elect Commun Engn, Menoufia 32952, Egypt
来源
IEEE ACCESS | 2024年 / 12卷
关键词
Electromagnetic interference; X-ray imaging; Security; MATLAB; Steganography; Image edge detection; Encryption; Medical diagnostic imaging; Computed tomography; Electronic medical records; Cryptography; Electronic medical images (EMI); security; privacy; cryptography; steganography;
D O I
10.1109/ACCESS.2024.3489452
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Electronic Medical Images (EMI) have grown with the increase in population. EMI are used for medical diagnosis for medical emergencies hence, they should be correct and clear for accurate diagnosis. In general, EMI are of varying sizes and dimensions. The aim is to enhance the security and privacy of EMI with reduced computational time while dealing with a larger and varying-sized data set. Reducing computational time will make the method suitable for real-time applications (RTA). Hence, a data set of 5856 secret X-ray images all varying in dimensions, total sized up to 1.16 GB, are applied with a hybrid of steganography and cryptography. Here, one X-Ray image is taken at a time then hidden into a single cover image using Edge-based steganography and then encrypted using five layers of cryptography. Various performance evaluation tests such as Structural Similarity Index Metrics (SSIM) achieved a value close to 1 which is the preferred value, Peak Signal-to-Noise Ratio (PSNR) is 82.51967 dB which is good, Mean Square Error (MSE) is 5.6E-09 which is close to zero indicating no addition of noise in the retrieved X-ray images, the Correlation (R) is 1. Therefore, the extracted image is the same as the original X-ray images, while remaining tests such as RMSE, Entropy, KLD, BER, SNR, CV, MAPE, PRD, etc. achieved good results. The computational time is measured by the Encryption Time (ET) is 0.37 seconds while the Decryption Time (DT) is 3.9275 sec. Thus, it can be concluded that a hybrid method (HM) could be implemented for RTA.
引用
收藏
页码:165050 / 165067
页数:18
相关论文
共 50 条
  • [1] Securing X-Ray Images in No Interest Region (NIR) of the Normalized Cover Image by Edge Steganography
    Sharma, Divya
    Prabha, Chander
    Gupta, Deepali
    Juneja, Sapna
    Abd-Elnaby, Mohammed
    Alraddady, Fahad
    Nauman, Ali
    IEEE Access, 2024, 12 : 168672 - 168689
  • [2] Encryption/Decryption of X-Ray Images Using Elliptical Curve Cryptography with Issues and Applications
    Pardesi, Vikas
    Khamparia, Aditya
    EMERGING ICT FOR BRIDGING THE FUTURE, VOL 2, 2015, 338 : 357 - 365
  • [3] A Cost Effective Approach for Securing Medical X-ray Images using Chebyshev Map
    Reddy, V. Praneeth Kumar
    Fathima, Annis A.
    2016 5TH INTERNATIONAL CONFERENCE ON RECENT TRENDS IN INFORMATION TECHNOLOGY (ICRTIT), 2016,
  • [4] SECURE AND EFFICIENT CLASSIFICATION OF CHEST X-RAY IMAGES USING CRYPTOGRAPHY AND MACHINE LEARNING TECHNIQUES
    Lekshmy, P. L.
    Rahiman, Abdul
    INTERNATIONAL JOURNAL FOR MULTISCALE COMPUTATIONAL ENGINEERING, 2025, 23 (01)
  • [5] MULTIPLE-LAYER TOMOGRAPHY USING 3 STATIONARY X-RAY IMAGES
    WANG, MT
    CHEN, JH
    YANG, CF
    YOSHIMOTO, C
    MEDICAL PHYSICS, 1986, 13 (04) : 574 - 574
  • [6] Postarthroplasty Examination Using X-Ray Images
    Varshney, Kush R.
    Paragios, Nikos
    Deux, Jean-Francois
    Kulski, Alain
    Raymond, Remy
    Hernigou, Phillipe
    Rahmouni, Alain
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (03) : 469 - 474
  • [7] A Hybrid Segmentation Algorithm for Rheumatoid Arthritis Diagnosis Using X-ray Images
    Rajesh, Govindan
    Malarvizhi, Nandagopal
    Leung, Man-Fai
    BIG DATA AND COGNITIVE COMPUTING, 2024, 8 (09)
  • [8] RESTORATION OF A THIN-LAYER OF WEAK X-RAY IMAGES
    RUSOV, VD
    SEMENOV, MY
    ZELENTSOVA, TN
    KOCHIKOV, IV
    REZNIK, BI
    KRAVCHENKO, SN
    YAGOLA, AG
    ZHURNAL TEKHNICHESKOI FIZIKI, 1989, 59 (07): : 181 - 183
  • [9] Exploiting Hybrid Methods for Enhancing Digital X-Ray Images
    Abu Sa'dah, Yusuf
    Al-Najdawi, Nijad
    Tedmori, Sara
    INTERNATIONAL ARAB JOURNAL OF INFORMATION TECHNOLOGY, 2013, 10 (01) : 28 - 35
  • [10] Detection of Hand Bone Fractures in X-Ray Images Using Hybrid YOLO NAS
    Medaramatla, Sai Charan
    Samhitha, Chennupati Veda
    Pande, Sagar Dhanraj
    Vinta, Surendra Reddy
    IEEE ACCESS, 2024, 12 : 57661 - 57673