Evaluation of perforated plate solar air heater

被引:5
|
作者
Khattab, N.M. [1 ]
机构
[1] Solar Energy Dept., National Research Center, Cairo, Egypt
关键词
Heat transfer coefficients - Solar energy;
D O I
10.1080/01425910008914363
中图分类号
学科分类号
摘要
Perforated plates had been successfully used in recent years to achieve high heat transfer coefficient from the absorber plate to the flowing air stream in solar air heaters. Since pumping pressure to maintain a particular flow in the solar air heater utilizing this type of absorber has significant influence on collected energy, so the design of perforated plate configuration must be based on the net energy gained from that collector which is the difference between energy collected and energy paid to overcome pumping pressure. A mathematical model had been constructed and validated experimentally for perforated plate solar air heater to study the effect of plate configurations and airflow rate on both energy gained and pressure loss. The results show that, the flow rate of air and plate configurations have a great effect on net energy gained from the air heater. The results also show that a plate of certain configurations operates most efficiently at certain flow rate and more than one configurations can give optimum value of net energy gained for a particular flow rate.
引用
收藏
页码:45 / 62
相关论文
共 50 条
  • [1] EVALUATION OF A JET PLATE SOLAR AIR HEATER
    CHOUDHURY, C
    GARG, HP
    SOLAR ENERGY, 1991, 46 (04) : 199 - 209
  • [2] Numerical analysis of a solar air heater with circular perforated absorber plate
    Shetty, Shreyas P.
    Madhwesh, N.
    Karanth, K. Vasudeva
    SOLAR ENERGY, 2021, 215 : 416 - 433
  • [3] Performance evaluation of solar air heater having V-down perforated baffles on the absorber plate
    Chamoli, Sunil
    Thakur, N. S.
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2013, 5 (06)
  • [4] Exergetic performance evaluation of solar air heater having V-down perforated baffles on the absorber plate
    Chamoli, S.
    Thakur, N. S.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2014, 117 (02) : 909 - 923
  • [5] Exergetic performance evaluation of solar air heater having V-down perforated baffles on the absorber plate
    S. Chamoli
    N. S. Thakur
    Journal of Thermal Analysis and Calorimetry, 2014, 117 : 909 - 923
  • [6] Thermal Evaluation of a Double-Pass Unglazed Solar Air Heater with Perforated Plate and Wire Mesh Layers
    Mahmood, Afaq Jasim
    SUSTAINABILITY, 2020, 12 (09)
  • [7] Performance evaluation of a smooth flat plate solar air heater
    Kumar, Thakur Sanjay
    Mittal, Vijay
    Thakur, N. S.
    Kumar, Anoop
    ENERGY EDUCATION SCIENCE AND TECHNOLOGY PART A-ENERGY SCIENCE AND RESEARCH, 2009, 23 (1-2): : 105 - 117
  • [8] Performance evaluation of a smooth flat plate solar air heater
    Mittal, Vijay
    Kumar, Thakur Sanjay
    Thakur, N.S.
    Kumar, Anoop
    Energy Education Science and Technology Part A: Energy Science and Research, 2009, 23 (02): : 105 - 117
  • [9] Performance evaluation of a novel solar air heater with arched absorber plate
    Singh, Simarpreet
    RENEWABLE ENERGY, 2017, 114 : 879 - 886
  • [10] Experimental study on a solar air heater with various perforated covers
    Raheleh Nowzari