Design and performance of the Elefant Digitizer IC for the BaBar Drift Chamber

被引:0
|
作者
E.O. Lawrence Berkeley Natl Lab, Berkeley, United States [1 ]
机构
来源
IEEE Trans Nucl Sci | / 4 I卷 / 785-791期
关键词
Analog to digital conversion - CMOS integrated circuits - Microprocessor chips - Readout systems - Sensor data fusion - Transistors;
D O I
暂无
中图分类号
学科分类号
摘要
A 250,000 transistor full custom integrated circuit for the readout of drift chamber signals has been developed, produced and characterized. The `Elefant' (ELEctronics For Amplitude 'N Timing) Digitizer IC is designed to measure both the charge and the single electron time of arrival of sense wire signals from the BaBar drift chamber. By combining a FADC (Flash Analog-to-Digital Converter) and a TDC (Time-to-Digital Converter) for each channel, the digitizer IC can be optimized and simplified, to achieve the physics goals required of the drift chamber while reducing the per channel costs of the electronics. The Elefant IC also implements portions of the BaBar Trigger protocols to simplify the connection of the chip to the rest of the BaBar detector. Each IC contains eight complete independent channels. The circuit has been implemented in a 0.8 μm triple metal CMOS process and fabricated in production quantity to fully instrument the BaBar Drift Chamber and are now in operation. Performance results of the IC will be presented.
引用
收藏
相关论文
共 50 条
  • [1] Design and performance of the Elefant Digitizer IC for the BaBar drift chamber
    Dow, SF
    Karcher, A
    Levi, ME
    Momayezi, M
    von der Lippe, H
    Ando, D
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) : 785 - 791
  • [2] Aging performance of the BaBar drift chamber
    Kelsey, MH
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3699 - 3703
  • [3] Performance and aging of the BaBar Drift Chamber
    Kelsey, MH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 535 (1-2): : 206 - 211
  • [4] The BaBar drift chamber
    Sciolla, G
    Bajic, A
    Bard, R
    Beaulieu, M
    Blinov, V
    Borsato, E
    Boucham, A
    Boutigny, D
    Boyarski, A
    Boyce, R
    Britton, D
    Brochu, B
    Bronzini, F
    Broomer, B
    Buccheri, A
    Caracciolo, R
    Colecchia, F
    Coupal, D
    Cowan, RF
    Coward, D
    DalCorso, F
    Dallapiccola, C
    DeBonis, I
    Dorfan, D
    Dow, S
    Dusatko, J
    Erdos, E
    Fanin, C
    Fernandez, J
    Fernholz, R
    Ferrarotto, F
    Ferroni, F
    Fong, D
    Ford, WT
    Gaddi, A
    Galeazzi, F
    Goodenough, C
    Gritsan, A
    Harris, J
    Harton, J
    Hasan, A
    Hearty, C
    Heise, J
    Henderson, R
    Hodgson, J
    Houde, M
    Jawahery, H
    Jeremie, A
    Johnson, DR
    Karcher, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 419 (2-3): : 310 - 314
  • [5] BaBar drift chamber
    Sciolla, G.
    Bajic, A.
    Bard, R.
    Beaulieu, M.
    Blinov, V.
    Borsato, E.
    Boucham, A.
    Boutigny, D.
    Boyarski, A.
    Boyce, R.
    Britton, D.
    Brochu, B.
    Bronzini, F.
    Broomer, B.
    Buccheri, A.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 419 (2-3): : 310 - 314
  • [6] The BaBar drift chamber project
    Boucham, A
    Boutigny, D
    De Bonis, I
    Jeremie, A
    Karyotakis, Y
    Lafaye, R
    Goodenough, C
    Hearty, C
    Heise, J
    Kelsey, M
    McKenna, J
    Dorfan, D
    Fernandez, J
    Sadrozinski, H
    Schumm, B
    Spencer, N
    Harton, J
    Malchow, R
    Smy, M
    Warner, D
    Broomer, B
    Erdos, E
    Ford, WT
    Gritsan, A
    Johnson, DR
    Krieg, H
    Roy, J
    Park, H
    Rankin, P
    Smith, JG
    Gaddi, A
    Morganti, M
    Raffaelli, F
    Borsato, E
    Caracciolo, R
    Dal Corso, F
    Fanin, C
    Morandin, M
    Posocco, M
    Santi, S
    Stroili, R
    Torassa, E
    Voci, C
    Bronzini, F
    Buccheri, A
    Ferroni, F
    Lamanna, E
    Mazzoni, MA
    Morganti, S
    Piredda, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3): : 46 - 52
  • [7] Electronics for the BaBar central drift chamber
    Albert, J.
    Bajic, A.
    Bard, R.
    Beaulieu, M.
    Blinov, V.
    Boyarski, A.
    Broomer, B.
    Coupal, D.
    Dal Corso, F.
    Dolinsky, S.
    Dorfan, D.
    Dow, S.
    Dubrovin, M.
    Dusatko, J.
    Erdos, E.
    et. al.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 2 : 896 - 901
  • [8] DIGITAL DRIFT CHAMBER DIGITIZER SYSTEM
    NITZ, D
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (01) : 246 - 250
  • [9] Electronics for the BaBar central drift chamber
    Albert, J
    Bajic, A
    Bard, R
    Beaulieu, M
    Blinov, V
    Boyarski, A
    Broomer, B
    Coupal, D
    Dal Corso, F
    Dolinsky, S
    Dorfan, D
    Dow, S
    Dubrovin, M
    Dusatko, J
    Erdos, E
    Faccini, R
    Fernandez, JP
    Ford, WT
    Galeazzi, F
    Haller, G
    Innes, W
    Jawahery, A
    Kreig, H
    Lankford, AJ
    Levi, M
    von der Lippe, H
    MacFarlane, DB
    Martin, JP
    Momayezi, M
    Morandin, M
    Morii, M
    Nelson, D
    Nguyen, P
    Palrang, M
    Roy, J
    Sadrozinski, H
    Schumm, B
    Sciolla, G
    Seiden, A
    Smith, AJS
    Spencer, E
    Soha, A
    Taras, P
    Varnes, E
    Weinstein, A
    Wilson, F
    Yushkov, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) : 2027 - 2032
  • [10] BaBar drift chamber aging study
    Lu, CG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2): : 125 - 128