Operating experience with a high-dust SCR plant in a lignite-fired 300 MW unit

被引:0
|
作者
Schoengrundner, W. [1 ]
Hiebler, J. [1 ]
Zierler, W. [1 ]
机构
[1] Oesterreichnische Draukraftwerke AG, Oesterreich, Germany
来源
VGB-Kraftwerkstechnik | 1995年 / 75卷 / 01期
关键词
Ammonia - Ammonium compounds - Catalysts - Equipment - Erosion - Fly ash - Monitoring;
D O I
暂无
中图分类号
学科分类号
摘要
After more than 10 000 operating hours, the experience can be summarized as follows: The devices for NH4OH supply had to be improved. It seems to be advisable to monitor the reduction agent consequently. Comprehensive countermeasures had to be taken in order to solve catalyst problems (fly ash deposits, erosion). The gaseous NH3 slip was monitored by observing the NH3 content in the fly ash. The results achieved so far are plausible. The future development will be of interest, particularly with increased NH3 slip.
引用
收藏
页码:61 / 66
相关论文
共 25 条
  • [1] A high-dust SCR plant at Conch Cement
    Thetis, Markus
    Schneider, Daniel
    ZKG INTERNATIONAL, 2020, 73 (04): : 28 - 29
  • [2] Content and course of an extensive main inspection of a 500 MW lignite-fired unit in the Jäschwalde Power Plant
    Weiß, G.
    Smurawski, G.-P.
    Wierick, G.
    VGB PowerTech, 2004, 84 (08): : 28 - 35
  • [3] Assessment of gaseous, PM and trace element emissions from a 300-MW lignite-fired boiler unit for various fuel qualities
    Kuprianov, V. I.
    Tanetsakunvatana, V.
    FUEL, 2006, 85 (14-15) : 2171 - 2179
  • [4] Experience with the co-combustion of sewage sludge in the Boxberg lignite-fired power plant of VEAG
    Wierick, H.-G.
    Brunne, Th.
    Richter, S.
    Heinze, D.
    Mielke, F.
    2001, VGB-Kraftswerktechnik GmbH (81): : 43 - 46
  • [5] Use of field bus technology in the 950-MW unit K of RWE Rheinbraun's Niederaußem lignite-fired power plant
    Hözel, B.
    Vocke, C.
    VGB PowerTech, 2002, 82 (03): : 75 - 80
  • [6] Impact of free calcium oxide content of fly ash on dust and sulfur dioxide emissions in a lignite-fired power plant
    Sotiropoulos, D
    Georgakopoulos, A
    Kolovos, N
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2005, 55 (07) : 1042 - 1049
  • [7] Enhancing the overall efficiency of a lignite-fired oxyfuel power plant with CFB boiler and membrane-based air separation unit
    Kotowicz, Janusz
    Balicki, Adrian
    ENERGY CONVERSION AND MANAGEMENT, 2014, 80 : 20 - 31
  • [8] Efficiency and power upgrade by an additional high pressure economizer installation at an aged 620 MWe lignite-fired power plant
    Stevanovic, Vladimir D.
    Wala, Tadeusz
    Muszynski, Slawomir
    Milic, Milos
    Jovanovic, Milorad
    ENERGY, 2014, 66 : 907 - 918
  • [9] Experience introduction of Heze power plant 300MW unit CCS
    Hou, DL
    Hu, HP
    Lü, SL
    Proceedings of the World Engineers' Convention 2004, Vol F-B, Power and Energy, 2004, : 139 - 145
  • [10] New Design of Gas and Residual Oil-Fired Boiler Unit for a 300 MW Power Plant Unit.
    Parshin, A.A.
    Levchenko, G.I.
    Khristich, L.M.
    Zaraiskii, S.I.
    Shleifer, B.M.
    Konashev, S.L.
    Energomashinostroenie, 1979, (01): : 14 - 17