HIGH-FIELD CONDUCTION AND ELECTRICAL BREAKDOWN OF POLYETHYLENE AT HIGH TEMPERATURES.

被引:0
|
作者
Hikita, Masayuki [1 ]
Tajima, Seiji [1 ]
Kanno, Ippei [1 ]
Ishino, Iwao [1 ]
Sawa, Goro [1 ]
Ieda, Masayuki [1 ]
机构
[1] Nagoya Univ, Dep of Electrical, Engineering, Nagoya, Jpn, Nagoya Univ, Dep of Electrical Engineering, Nagoya, Jpn
来源
Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes | 1985年 / 24卷 / 08期
关键词
ELECTRIC BREAKDOWN - ELECTRIC CONDUCTIVITY;
D O I
暂无
中图分类号
学科分类号
摘要
The mechanism of the breakdown occurring when a dc ramp voltage is applied to low-density polyethylene (LDPE) and silane cross-linked PE at high temperatures is discussed, using experimental results on the Young's modulus Y, high-field conduction and pre-breakdown currents. The electric strength F//B of PE was found to be a function of Y, irrespective of cross-linking. it was also found that, over a wide temperature range, a sharp pre-breakdown current increase could not be detected till a time before breakdown of 100 ns, the resolution limit of the measuring system. The results showed that, under the present experimental conditions, thermal breakdown is not applicable to PE over a wide temperature range and that breakdown is initiated by an electronic process which has a very short time lag to breakdown of the order of some tens of ns or less.
引用
收藏
页码:988 / 996