MODIFIED T-VALUE METHOD FOR SELECTION OF STRAIN GAGES FOR MEASURING LOADS ON A LOW ASPECT RATIO WING.

被引:0
|
作者
Tang, Ming H.
Sheldon, Robert G.
机构
来源
NASA Technical Paper | 1980年 / 1748期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The paper describes a technique which may be useful for selecting strain gages for use in load equations. The technique is an adaptation of the previously used T-value method and is applied in this paper to a multispar structure. The technique, called the modified T-value method, is used to reduce the numer of strain gages used in a load equation from 12 to two. A parallel reduction is made using the previously developd T-value method. The two methods are compared by calculating relative equation accuracies from three applied load distributions. The equations developed from the modified T-value method proved to be accurate more consistently than the T-value method.