METAL-HALIDE LAMPS - SODIUM IODIDE - SODIUM LOSS - THERMAL ION EMISSION;
D O I:
暂无
中图分类号:
学科分类号:
摘要:
Metal-halide lamps containing NaI have thermal ion emission, causing Na loss. No neutral flux could be detected using either mass spectrometry or atomic absorption methods. There was no Na concentration gradient in or on the arc tube wall. Strong external UV radiation had no effect on sodium loss.