Selective control of base-isolated structures with CS dampers

被引:0
|
作者
Gluck, J.
Ribakov, Y.
Dancygier, A.N.
机构
关键词
D O I
10.1193/1.1586129
中图分类号
学科分类号
摘要
Addition of dampers to a base isolator reduces base displacements but may increase floor accelerations and interstory drifts. This paper presents a `selective control approach' for the design of base-isolated active controlled structures with Controlled Stiffness Dampers (CSD). According to this approach the dampers are activated only within a given range of the base displacement. The optimal damping forces are calculated according to structure's displacements and velocities. However, because of the CS dampers' structure the actual application of the forces is independent of the displacement and the velocity that are transferred to the device. These forces depend only on the geometry and on the mechanical properties of the devices' springs. The efficiency of the proposed method is demonstrated in a numerical example.
引用
收藏
页码:593 / 606
相关论文
共 50 条
  • [1] Base-isolated structures with selective controlled semi-active friction dampers
    Ribakov, Y.
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2011, 20 (07): : 757 - 766
  • [2] Optimization research for base-isolated structures with fluid viscous dampers
    Chen R.
    Wu J.
    Liu Y.
    Donà M.
    Jin J.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2020, 39 (11): : 93 - 100
  • [3] PREDICTIVE CONTROL OF BASE-ISOLATED STRUCTURES
    INAUDI, J
    LOPEZALMANSA, F
    KELLY, JM
    RODELLAR, J
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1992, 21 (06): : 471 - 482
  • [4] Predictive control of base-isolated structures
    Inaudi, J.
    Lopez-Almansa, F.
    Kelly, J.M.
    Rodellar, J.
    Earthquake Engineering and Structural Dynamics, 1992, 21 (06) : 471 - 482
  • [5] Optimal design of tuned liquid column dampers for seismic response control of base-isolated structures
    Alberto Di Matteo
    Thomas Furtmüller
    Christoph Adam
    Antonina Pirrotta
    Acta Mechanica, 2018, 229 : 437 - 454
  • [6] Optimal design of tuned liquid column dampers for seismic response control of base-isolated structures
    Di Matteo, Alberto
    Furtmueller, Thomas
    Adam, Christoph
    Pirrotta, Antonina
    ACTA MECHANICA, 2018, 229 (02) : 437 - 454
  • [7] Near-source earthquakes, base-isolated structures and semiactive dampers
    Makris, N
    EARTHQUAKE RESISTANT ENGINEERING STRUCTURES, 1997, 2 : 291 - 300
  • [8] Near-source earthquakes, base-isolated structures and semiactive dampers
    Department of Civil Engineering and Geological Sciences, University of Notre Dame, Notre Dame, IN 46556, United States
    WIT Trans. Built Environ., (291-300):
  • [9] THE EFFECT OF TUNED-MASS DAMPERS ON THE SEISMIC RESPONSE OF BASE-ISOLATED STRUCTURES
    TSAI, HC
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 1995, 32 (8-9) : 1195 - 1210
  • [10] Robust active control of hysteretic base-isolated structures: Application to the benchmark smart base-isolated building
    Pozo, Francesc
    Montserrat, Pere Marc
    Rodellar, Jose
    Acho, Leonardo
    STRUCTURAL CONTROL & HEALTH MONITORING, 2008, 15 (05): : 720 - 736