CIRCUIT BREAKER AND PROTECTION REQUIREMENTS FOR DC SWITCHGEAR USED IN RAPID TRANSIT SYSTEMS.

被引:0
|
作者
Morton, John S. [1 ]
机构
[1] Whipp & Bourne Ltd, Rochdale, Engl, Whipp & Bourne Ltd, Rochdale, Engl
关键词
ELECTRIC CIRCUIT BREAKERS - Transients - ELECTRIC RAILROADS - Power Supply - ELECTRIC SWITCHGEAR - Protection;
D O I
暂无
中图分类号
学科分类号
摘要
Attention is drawn to the interrupting severities encountered by dc circuit breakers on rapid transit systems and how specifications can more clearly define these conditions. The various protection equipment requirements are discussed, and it is shown that one of these requirements is difficult because of the similarity which can exist between healthy and abnormal conditions, making discrimination under certain conditions almost impossible. A guide is given to the minimum requirements for the dc switchgear which should ensure a reliable and secure power supply to the rapid transit system.
引用
收藏
页码:1268 / 1273
相关论文
共 50 条
  • [2] Circuit Breaker Protection Considerations in Power Converter-Fed DC Systems
    Cuzner, Rob
    MacFarlin, Doug
    Clinger, Don
    Rumney, Michael
    Castles, Gene
    2009 IEEE ELECTRIC SHIP TECHNOLOGIES SYMPOSIUM, 2009, : 360 - +
  • [3] PROTECTION REQUIREMENTS INFLUENCE CIRCUIT-BREAKER DESIGN
    ROBBINS, JA
    ELECTRICAL REVIEW, 1973, 192 (19): : 675 - &
  • [4] Analysis on the Unidirectional DC Circuit Breaker and Protection Strategy
    Yang, Tian
    Liu, Xiaoming
    Wu, Qi
    Chen, Hai
    Li, Longnv
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2020, 35 : 259 - 266
  • [5] Solid-State Circuit Breaker Protection for DC Shipboard Power Systems: Breaker Design, Protection Scheme, Validation Testing
    Qi, Li
    Cairoli, Pietro
    Pan, Zach
    Tschida, Colin
    Wang, Zhenyuan
    Ramanan, V. R.
    Raciti, Luca
    Antoniazzi, Antonello
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2020, 56 (02) : 952 - 960
  • [6] Overcurrent protection of marine air DC circuit breaker
    Tu, Zhengxiang
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2010, 38 (06): : 67 - 70
  • [7] TRENDS OF HIGH VOLTAGE SWITCHGEAR REQUIREMENTS STRONGLY INTERCONNECTED SYSTEMS.
    Beehler, James E.
    Energia Elettrica, 1983, 60 (12): : 451 - 460
  • [8] Stray Current Corrosion and Mitigation: A synopsis of the technical methods used in dc transit systems.
    Memon, Saud A.
    Fromme, Paul
    IEEE Electrification Magazine, 2014, 2 (03): : 22 - 31
  • [9] Design and Research on DC Electric Leakage Protection Circuit Breaker
    Hou, Lei
    Chen, Dezhi
    Li, Tongfei
    Zhao, Ming
    Ren, Huaibo
    ENERGIES, 2022, 15 (15)
  • [10] Modelling and Evaluation of Low Voltage DC Circuit Breaker for the Protection of DC Microgrid
    Pramudya, I.
    Khan, Umer A.
    Suwarno
    Koo, J. Y.
    Lee, B. W.
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 295 - 298