Optimization of stresses in the end-fittings of composite insulators for distribution and transmission lines

被引:0
|
作者
Inst de Recherche d'Hydro-Quebec, Varennes, Canada [1 ]
机构
来源
J Reinf Plast Compos | / 5卷 / 467-478期
关键词
Anisotropy - Bearing capacity - Calculations - Elasticity - Electric insulators - Electric lines - Failure (mechanical) - Geometry - Mechanical properties - Optimization - Stress concentration - Stresses;
D O I
暂无
中图分类号
学科分类号
摘要
This paper addresses the problem of stress calculation and optimization in a FRP (Fibre-glass Reinforced Plastic) pultruded rod crimped into a metal end-fitting. This type of assembly is used mainly for suspension and line post insulators. We discuss herein some aspects that merit consideration in any given design approach. In many respects FRP pultruded materials are anisotropic. The anisotropic of their elastic constants influences the distribution of stresses while the anisotropy of their mechanical properties (ultimate strengths) limits their load carrying capacity. Finally, the anisotropy of their failure modes governs the progression and the spread of the damage. Each level of anisotropy will be discussed distinctly. Geometrical considerations are also necessary to arrive at an efficient design. Namely, we will consider the frictional interactions between the end-fitting inner wall and the rod, then we will present our approach in selecting the appropriate L/D ratio (i.e., the ratio of the end-fitting length over the rod diameter), and finally we will discuss the influence of the compression profile, i.e., the permanent radial displacement imparted to the rod due to the action of the crimping force.
引用
收藏
相关论文
共 50 条
  • [1] Optimization of stresses in the end-fittings of composite insulators for distribution and transmission lines (Reprinted from Enercomp '95, Proceedings of the International Conference on Composite Materials and Energy, May 8-10, 1995)
    Lanteigne, J
    Lalonde, S
    deTourreil, C
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 1996, 15 (05) : 467 - 478
  • [2] Stress concentration testing of composite insulators with crimped end-fittings
    Dai, JJ
    Liang, XD
    Zhou, YX
    Yao, XF
    2004 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2004, : 619 - 622
  • [3] Mechanical evaluation of axially loaded composite insulators with crimped end-fittings
    Bansal, A
    Kumosa, M
    JOURNAL OF COMPOSITE MATERIALS, 1997, 31 (20) : 2074 - 2104
  • [4] Analyses of composite insulators with crimped end-fittings: part II - Suitable crimping conditions
    Kumosa, M
    Armentrout, D
    Kumosa, L
    Han, Y
    Carpenter, SH
    COMPOSITES SCIENCE AND TECHNOLOGY, 2002, 62 (09) : 1209 - 1221
  • [5] Analyses of composite insulators with crimped end-fittings: Part I - non linear finite element computations
    Kumosa, M
    Han, Y
    Kumosa, L
    COMPOSITES SCIENCE AND TECHNOLOGY, 2002, 62 (09) : 1191 - 1207
  • [6] Brittle fracture of non-ceramic suspension insulators with epoxy cone end-fittings
    Kumosa, M
    Narayan, HS
    Qiu, Q
    Bansal, A
    COMPOSITES SCIENCE AND TECHNOLOGY, 1997, 57 (07) : 739 - 751
  • [7] DEVELOPMENTS IN COMPOSITE INSULATORS FOR TRANSMISSION LINES
    LOOMS, JST
    ELECTRICAL REVIEW, 1971, 189 (04): : 117 - &
  • [8] Non-Uniform Distribution of Contamination on Composite Insulators in HVDC Transmission Lines
    Zhang, Zhijin
    Qiao, Xinhan
    Yang, Shenghuan
    Jiang, Xingliang
    APPLIED SCIENCES-BASEL, 2018, 8 (10):
  • [9] APPLICATION OF COMPOSITE INSULATORS TO TRANSMISSION-LINES
    CHERNEY, EA
    KARADY, G
    BROWN, RL
    NICHOLLS, JL
    ORBECK, T
    PARGAMIN, L
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (05): : 1226 - 1234
  • [10] Sheds configuration optimization of AC composite insulators used in AC transmission lines at icing areas based on electric field distribution
    Jiang, Xingliang
    Liu, Yu
    Zhang, Zhijin
    Hu, Jianlin
    Yin, Fanghui
    Xiang, Ze
    Gaodianya Jishu/High Voltage Engineering, 2013, 39 (01): : 210 - 217