Tuned mass dampers for structures with closely spaced natural frequencies

被引:0
|
作者
Abe, M. [1 ]
Igusa, T. [1 ]
机构
[1] Northwestern Univ, Evanston, United States
来源
关键词
Harmonic load - Structural modal masses - Tuned mass damper;
D O I
暂无
中图分类号
学科分类号
摘要
Analytical results are developed for vibration control of structures with one or more Tuned Mass Dampers (TMDs). The input is a harmonic load with a range of possible frequencies. The control objective is to reduce the maximum amplitude of the structural response. Perturbation theory is used with three sets of small parameters: the ratio of TMD and structural modal masses, the damping of the system, and the differences between the structural and loading frequencies. It is shown analytically that for structures with widely spaced natural frequencies, the response can be approximated accurately by the response of the well-known single-mode structure/TMD system. For structures with p closely spaced natural frequencies, more general analytical results are developed to describe the coupling between the motions of the p modes of the structure and the multiple TMDs. The results show that at least p TMDs with properly placed attachments to the structure are necessary to control the response. If fewer TMDs are used, the maximum frequency response has a lower bound which is independent of the properties of the TMDs. The TMD placement is shown to be always important, regardless of the spacing of the structure's natural frequencies. The results are illustrated for both lumped-mass and continuous structures.
引用
收藏
页码:247 / 261
相关论文
共 50 条
  • [1] TUNED MASS DAMPERS FOR STRUCTURES WITH CLOSELY SPACED NATURAL FREQUENCIES
    ABE, M
    IGUSA, T
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1995, 24 (02): : 247 - 261
  • [2] Judging Criterion of Controlled Structures with Closely Spaced Natural Frequencies
    Xie Faxiang
    Sun Limin
    ISCM II AND EPMESC XII, PTS 1 AND 2, 2010, 1233 : 360 - 365
  • [3] On Controllability of Structures with Closely Spaced Natural Frequencies Based on Perturbation Analysis
    Xie Faxiang
    Sun Limin
    ISCM II AND EPMESC XII, PTS 1 AND 2, 2010, 1233 : 753 - 758
  • [4] NONSTATIONARY RESPONSE OF STRUCTURES WITH CLOSELY SPACED FREQUENCIES
    XU, KM
    IGUSA, TR
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 1992, 118 (07): : 1387 - 1405
  • [5] Tuned mass dampers for structures with bilinear hysteresis
    Abe, M
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 1996, 122 (08): : 797 - 800
  • [6] A constrained optimal Rayleigh damping coefficients for structures with closely spaced natural frequencies in seismic analysis
    Pan, D. G.
    Chen, G. D.
    Gao, L. L.
    ADVANCES IN STRUCTURAL ENGINEERING, 2017, 20 (01) : 81 - 95
  • [7] Active control of a structure with continuously closely spaced natural frequencies
    Sun, H. L.
    Zhang, P. Q.
    Chen, H. B.
    Zhang, K.
    JOURNAL OF SOUND AND VIBRATION, 2006, 294 (1-2) : 15 - 22
  • [8] Vibration control of structures with closely spaced frequencies by a single actuator
    Abe, M
    JOURNAL OF VIBRATION AND ACOUSTICS-TRANSACTIONS OF THE ASME, 1998, 120 (01): : 117 - 124
  • [9] DYNAMIC ANALYSIS OF STRUCTURES WITH MULTIPLE TUNED MASS DAMPERS
    Lewandowski, Roman
    Grzymislawska, Justyna
    JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2009, 15 (01) : 77 - 86
  • [10] Active tuned tandem mass dampers for seismic structures
    Li, Chunxiang
    Cao, Liyuan
    EARTHQUAKES AND STRUCTURES, 2019, 17 (02) : 143 - 162