New method for increasing the accuracy of back titration

被引:0
|
作者
Li, Nai-Xuan
Xiao, Ru-Ting
Dong, Ying
Wu, Zhi-Dong
Ge, Ming
机构
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Titrimetric analysis is an important quantitative analysis method in which the amount of constituent to be determined is calculated from the volumes and concentrations of titrants used in titration procedure. In most literature about titrimetric analysis it has been emphasized that the volumes of titrants used in a titration procedure should be greater than 20 mL to obtain more accurate titration result by reducing the relative error of volume of titrants. By the theory of error propagation, therefore, this emphasis stated above is not valid for a back titration procedure. In back titration procedure the constituent to be determined, represented by A, reacts with the direct titrant, represented by B, according to reaction αA+bB-&gtyY+zZ when an excess of Be is added to the titration vessel that contains A. Then the amount of excess is determined by titration with back titrant, represented by D, according to reaction dD+fB-&gtgG+hH. The amount of A, represented by NA, can be calculated by equation NA = a÷b·(CB·VB-f÷d·CD·VD), where CB, CD, VB and VD represent the concentrations and volumes of B and D respectively. Introducing the concept of limit error and using the theory of error propagation here, the limit relative error of NA may be shown as qq where |ECB|, |ECD|, |EVB|, |EVD|, and |ENA| represent the absolute limit error of CB, CD, VB, VD and NA respectively; XA, XB and XD are the limit relative error of A, B and D; XA = |ENA|/NA, XB = |ECB|/CB, XD = |ECD|/CD, and q=(CB ·d)/(CD ·f). For a special back titration procedure, apparently, the value of each of |EVB| and EVD|, created by reading error of pipette and burette respectively, should be a constant. Similarly, the value of each of q, q·|EVB|+|EVD|, CB, CD, XB and XD should be a constant too. Considering NA = a·CB ·(q·VB - VD)/(b·q), the value of q·VB - VD will remain constant when the value of NA is unchanged, although the values of VB and VD may vary. Consequently, the conclusions for back titration can be drawn from equation (1) that the linear relationship between the values of XA and VD exists and that the bigger VD, the bigger XA. Also it can be seen from equation (1) that no relationship exists between the values of |EVD|/VD and XA. Thus, if there is a outside demand for XA to be smaller than a specified permissible error X, the suitable values of VB and VD that satisfy XA B gt; VBMIN =(q· |EVB|+|EVD|) / [q·(X-XB)] VD DMAX =[q·VB ·(X-XB) - (q· |EVB|+|EVD|)] / (X+XD) where VDMAX is the biggest permissible value of VD and VBMIN is the smallest permissible value of VB.
引用
收藏
相关论文
共 50 条
  • [1] ACCURACY AND PRECISION ENHANCEMENT FOR TOTAL RESIDUAL CHLORINE BACK TITRATION
    STOCKMEIER, LA
    HUBER, CO
    KOHL, JE
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1987, 59 (12): : 1075 - 1077
  • [2] An automatic back titration method for microchemical analysis
    Tan, AM
    Xiao, CL
    TALANTA, 1997, 44 (06) : 967 - 972
  • [3] A New Method For Increasing the Accuracy of EM-based Channel Estimation
    Sadough, Seyed Mohammad-Sajad
    Modarresi, Mohammad
    RADIOENGINEERING, 2011, 20 (04) : 968 - 975
  • [4] APODIZATION METHOD OF INCREASING RISING ACCURACY
    TIKHOMIROVA, MG
    RADIOTEKHNIKA I ELEKTRONIKA, 1978, 23 (11): : 2293 - 2297
  • [5] Increasing of AC compensation method accuracy
    Havlícek, V
    Pokorny, M
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2003, 254 : 76 - 78
  • [6] NEW METHOD FOR TITRATION OF KETAMINE
    LELEU, JC
    LIAGRE, A
    BEGARD, P
    GENTILINI, C
    LAGETCORSIN, L
    ANESTHESIE ANALGESIE REANIMATION, 1976, 33 (02): : 297 - 302
  • [7] A new method for increasing accuracy of distance measurement based on single visual camera
    Zewei Liu
    Dongming Lu
    Weixian Qian
    Kan Ren
    Guohua Gu
    Jun Zhang
    Chen Mao
    Optical and Quantum Electronics, 2019, 51
  • [8] A New Method of Increasing the Measurement Accuracy in Adaptive Measurement Systems with Bank of Sensors
    Jedrzejewski, Konrad
    2018 INTERNATIONAL CONFERENCE ON SIGNALS AND ELECTRONIC SYSTEMS (ICSES 2018), 2018, : 96 - 101
  • [9] A new method for increasing accuracy of distance measurement based on single visual camera
    Liu, Zewei
    Lu, Dongming
    Qian, Weixian
    Ren, Kan
    Gu, Guohua
    Zhang, Jun
    Mao, Chen
    OPTICAL AND QUANTUM ELECTRONICS, 2019, 51 (03)
  • [10] METHOD OF COLLOID TITRATION (A NEW TITRATION BETWEEN POLYMER IONS)
    TERAYAMA, H
    JOURNAL OF POLYMER SCIENCE, 1952, 8 (02): : 243 - 253