The dosimetric verification of commercial two-and three-dimensional radiation treatment planning systems

被引:0
|
作者
Kilį, Ayhan [1 ]
Özkan, Lütfi [1 ]
Engin, Kayihan [1 ]
机构
[1] Uludaǧ University, Medical College, M. A. Radiotherapy Center, 16059 Gorukle Campus, Bursa, Turkey
关键词
Algorithms - Computational geometry - Computerized tomography - Planning - Quality assurance - Radiation effects;
D O I
暂无
中图分类号
学科分类号
摘要
For the quality assurance (QA) of radiation treatment planning systems (RTPSs) and planning computed tomography (CT), a simple cylindrical phantom was developed. The phantom was constructed by using materials and geometries appropriate for the routine clinic setups. A Siemens Somatom HiQ CT, two-dimensional (2D) and three-dimensional (3D) RTPS and a linear accelerator Siemens Mevatron MD2 were used in this study. The 2D and 3D RTPSs gave good results when compared to actual doses measured in the phantom. While the 3D system showed accuracy similar (-1.0% vs. -0.8%) to that of the 2D system for 6 MV and better accuracy (+1.4% vs. +2.2%) for 15 MV. but the improvement was not large. The phantom described in this study provides simple measurements that enable one to check an RTPS calculation algorithm under inhomogeneous conditions and it gives accurate and reproducible results.
引用
收藏
页码:133 / 137
相关论文
共 50 条
  • [1] Dosimetric verification of two commercially available three-dimensional treatment planning systems using the TG 23 test package
    Ramsey, CR
    Cordrey, IL
    Spencer, KM
    Oliver, AL
    MEDICAL PHYSICS, 1999, 26 (07) : 1188 - 1195
  • [2] Two-and Three-dimensional Rings in Drugs
    Aldeghi, Matteo
    Malhotra, Shipra
    Selwood, David L.
    Chan, Ah Wing Edith
    CHEMICAL BIOLOGY & DRUG DESIGN, 2014, 83 (04) : 450 - 461
  • [3] Dosimetric evaluation of a three-dimensional treatment planning system
    Murugan, Appasamy
    Valas, Xavier Sidonia
    Thayalan, Kuppusamy
    Ramasubramanian, Velayudham
    JOURNAL OF MEDICAL PHYSICS, 2011, 36 (01) : 15 - 21
  • [4] Dosimetric Verification of stereotactic Radiation Treatment Planning
    Senn, A. M.
    Garbe, S.
    Muedder, T.
    Schoroth, F.
    Roehner, F.
    Koch, D.
    Schmeel, C.
    Wilhelm-Buchstab, T.
    Leitzen, C.
    Heimann, M.
    Tschirner, S.
    Buecheler, B.
    Baumert, B. G.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 : S70 - S70
  • [5] Dosimetric verification of a commercial inverse treatment planning system
    Lei, X
    Curran, B
    Hill, R
    Holmes, T
    Ma, LJ
    Forster, KM
    Boyer, AL
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (02): : 463 - 478
  • [6] Three-dimensional radiation treatment planning: Principles and practice
    Zimmermann, FB
    Molls, M
    ONKOLOGIE, 1998, 21 (06): : 474 - 484
  • [7] Methodology of three-dimensional dosimetric dose verification in radiosurgery
    Scheib, SG
    Gianolini, S
    RADIOSURGERY, VOL 4, 2002, 4 : 203 - 212
  • [8] Simulating two-and three-dimensional frustrated quantum systems with string-bond states
    Sfondrini, Alessandro
    Cerrillo, Javier
    Schuch, Norbert
    Cirac, J. Ignacio
    PHYSICAL REVIEW B, 2010, 81 (21)
  • [10] Two-and Three-Dimensional Chloride Ingress into Fly Ash Concrete
    张云升
    Journal of Wuhan University of Technology(Materials Science), 2011, (05) : 978 - 982