Right at the tip: The closing behaviour of non-return valves

被引:0
|
作者
Gornik, C. [1 ]
Bleier, H. [1 ]
Roth, W. [1 ]
机构
[1] Process Engineering Department, Battenfeld Kunststoffmaschinen GmbH, Kottingbrunn, Austria
来源
| 2001年 / Carl Hanser Verlag卷 / 91期
关键词
Mathematical models - Nozzles - Plastics molding machines - Shear stress - Valves (mechanical);
D O I
暂无
中图分类号
学科分类号
摘要
The annular non return valve model used in injection molding machines was described. These valves can be designed with a forced rotation or optionally rotating outer section though preference is given to the latter due to its favorable wear behavior. They were observed to close most reliably and hence a comprehensive theoretical observation was performed. Their closing behavior was optimized as a function of the geometric layout of the non return valve.
引用
收藏
相关论文
共 50 条
  • [1] Right at the tip - The closing behaviour of non-return valves
    Gornik, C
    Bleier, H
    Roth, W
    KUNSTSTOFFE-PLAST EUROPE, 2001, 91 (06): : 72 - +
  • [2] The tip decides - Avoiding wear in non-return valves
    Gornik, C
    Bleier, H
    Roth, W
    KUNSTSTOFFE-PLAST EUROPE, 2001, 91 (01): : 64 - +
  • [3] Study of dynamic behaviour of non-return valves
    Francois, P
    HYDRAULIC MACHINERY AND CAVITATION, VOLS I AND II, 1996, : 494 - 503
  • [4] Time for another look at non-return valves
    Bozzelli, John
    Plastics Technology, 2017, 63 (08) : 30 - 32
  • [5] NEW DESIGNS OF SAFETY AND NON-RETURN VALVES
    PONOMAREV, AS
    RUSSIAN ENGINEERING JOURNAL-USSR, 1970, 50 (11): : 59 - +
  • [6] Biosafety of Non-Return Valves for Infusion Systems in Radiology
    Marcela Padilha Facetto Azevedo
    Rachel Maciel Monteiro
    Carla Castelani
    Felipe Lazarini Bim
    Lucas Lazarini Bim
    Ana Paula Macedo
    Viviane de Cássia Oliveira
    Evandro Watanabe
    Scientific Reports, 10
  • [7] Biosafety of Non-Return Valves for Infusion Systems in Radiology
    Facetto Azevedo, Marcela Padilha
    Monteiro, Rachel Maciel
    Castelani, Carla
    Bim, Felipe Lazarini
    Bim, Lucas Lazarini
    Macedo, Ana Paula
    Oliveira, Viviane de Cassia
    Watanabe, Evandro
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [8] RELIABILITY STILL MISSING FROM NON-RETURN VALVES
    COOKE, B
    PROCESS ENGINEERING, 1975, (MAY) : 72 - 75
  • [9] An approach to calculating wear on annular non-return valves
    Potente, H
    Többen, WH
    Kaiser, E
    MACROMOLECULAR MATERIALS AND ENGINEERING, 2002, 287 (11) : 800 - 807
  • [10] INCREASED MILKING VACUUM IN TEATCUPS FITTED WITH NON-RETURN VALVES
    ANDREWS, RJ
    MEIN, GA
    WILLIAMS, DM
    JOURNAL OF DAIRY RESEARCH, 1988, 55 (04) : 495 - 503