PERFORMANCE ON THE SOLAR TOTAL ENERGY SYSTEM EXPERIMENTAL FACILITY WITH AUXILIARY HEATER.

被引:0
|
作者
Sawata, S.
Tanaka, T.
Tani, T.
机构
关键词
COMPUTER SIMULATION - ELECTRIC POWER GENERATION - Equipment;
D O I
暂无
中图分类号
学科分类号
摘要
This paper describes the computer simulation program developed for establishing the optimum design of solar total energy system with auxiliary heater and the characteristics of the experimental facility determined by using it. An experimental solar total energy system test facility of rated electric power capacity 15 kW and rated thermal supply capacity 45 kW has been developed and operated under various conditions. This facility has three operating modes with different solar radiation intensity and temperature conditions of the heat storage systems. Free operating mode is the combination of three modes. It has been found that the free operating mode is the most useful one, in terms of annual operating hours and electric output.
引用
收藏
页码:297 / 310
相关论文
共 50 条
  • [1] SYSTEM PERFORMANCE OF SOLAR TOTAL ENERGY EXPERIMENTAL FACILITY.
    Tanaka, Tadayoshi
    Tani, Tatsuo
    Sawata, Shinji
    Sakuta, Koichi
    Tsuda, Izumi
    Ezawa, Noboru
    Fujiwara, Masanori
    Bulletin of the Electrotechnical Laboratory, Tokyo, 1982, 46 (10): : 60 - 66
  • [2] PERFORMANCE MEASURES OF THE AXICON SOLAR FLUID HEATER.
    El-Refaie, M.F.
    Heat and Technology, 1988, 6 (1-2): : 70 - 96
  • [3] CONSTRUCTION OF EXPERIMENTAL FACILITY OF SOLAR TOTAL ENERGY SYSTEM.
    Tanaka, Tadayoshi
    Sawata, Shinji
    Sakuta, Koichi
    Tsuda, Izumi
    Tani, Tatsuo
    Bulletin of the Electrotechnical Laboratory, Tokyo, 1983, 47 (05): : 311 - 428
  • [4] PERFORMANCE OF AN INEXPENSIVE UNDERGROUND SHALLOW SOLAR POND WATER HEATER.
    Tiwari, G.N.
    Garg, H.P.
    Singh, U.
    Madhuri
    1600, (24):
  • [5] PERFORMANCE OF A TWO CHANNEL SUSPENDED FLAT PLATE SOLAR AIR HEATER.
    Indian Inst of Technology, Cent of, Energy Studies, New Delhi, India, Indian Inst of Technology, Cent of Energy Studies, New Delhi, India
    Energy Convers Manage, 1600, 4 (269-275):
  • [6] EFFECT OF AMBIENT AIR TEMPERATURE ON PERFORMANCE OF VACUUM TUBE SOLAR WATER HEATER.
    Soliman, S.H.
    Tadros, W.H.
    Journal of the Institution of Engineers (India), Part IDP: Interdisciplinary Panels, 1988, 68 : 33 - 36
  • [7] THE IMPACT OF POWER OF THE AUXILIARY ELECTRIC HEATER IN THE STORAGE TANK ON THE PERFORMANCE OF A THERMOSIPHON SOLAR WATER-SYSTEM WITH AN AUXILIARY ELECTRIC HEATER (TSAEH)
    WENXIAN, L
    ENRONG, L
    ENERGY, 1995, 20 (12) : 1265 - 1270
  • [8] Experimental analysis of hybrid dryer combined with spiral solar air heater and auxiliary heating system: Energy, exergy and economic analysis
    Heydari, Ali
    RENEWABLE ENERGY, 2022, 198 : 1162 - 1175
  • [9] Performance investigation of solar thermal collector with auxiliary heater for space heating
    Biglarian, Hassan
    Sharfabadi, Mohammad Mazidi
    Alizadeh, Mansour
    Gharaei, Hossein
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2021, 28 (11) : 3466 - 3476
  • [10] THE SOLAR WATER HEATING-SYSTEM WITH NATURAL CIRCULATION ASSISTED BY AN AUXILIARY ELECTRIC HEATER PERFORMANCE MODELING
    WENXIAN, L
    ENRONG, L
    DONGCHENG, W
    ENERGY CONVERSION AND MANAGEMENT, 1991, 31 (05) : 409 - 418