Radiometric applications of Fourier-transform spectrometers

被引:0
|
作者
Ctr. Optical and Environ. Metrol., National Physical Laboratory, Middlesex TW11 0LW, United Kingdom [1 ]
机构
来源
Metrologia | / 4卷 / 529-534期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Filter radiometers are used as transfer standards in many radiometric measurements, and essentially comprise a detector, filter (interference or coloured glass) and high-precision aperture. An initial study into the use of Fourier-transform (FT) spectrometry has resulted in the attainment of medium accuracy (around 0.3 % to 0.7 %) calibration of assembled filter radiometers in a period of a few hours. This contrasts with a day for characterization using a grating instrument and the weeks required for high-resolution, high-accuracy, laser-based calibration. The technique measures the response of the radiometer to be calibrated against that of a standard detector, which in this case is a trap detector.
引用
收藏
相关论文
共 50 条
  • [1] Radiometric applications of fourier-transform spectrometers
    Chunnilall, CJ
    Fox, NP
    Theocharous, E
    MIKROCHIMICA ACTA, 1997, : 175 - 177
  • [2] Radiometric applications of Fourier-transform spectrometers
    Chunnilall, CJ
    Fox, NP
    METROLOGIA, 1998, 35 (04) : 529 - 534
  • [3] A procedure for testing the radiometric accuracy of fourier-transform infrared spectrometers
    Zhang, ZM
    Hanssen, LM
    Hsia, JJ
    Datla, RU
    Zhu, CJ
    Griffiths, PR
    MIKROCHIMICA ACTA, 1997, : 315 - 316
  • [4] CRYOGENICALLY COOLED FOURIER-TRANSFORM SPECTROMETERS
    HUPPI, RJ
    STEED, AJ
    HUPPI, ER
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 289 : 345 - 354
  • [5] Miniaturization of holographic Fourier-transform spectrometers
    Agladze, NI
    Sievers, AJ
    APPLIED OPTICS, 2004, 43 (36) : 6568 - 6579
  • [6] Static Fourier-Transform Waveguide Spectrometers
    Delage, Andre
    Cheben, Pavel
    Florjanczyk, Miroslaw
    Janz, Siegfried
    Lamontagne, Boris
    Lapointe, Jean
    Scott, Alan
    Solheim, Brian
    Xu, Dan-Xia
    ICTON: 2009 11TH INTERNATIONAL CONFERENCE ON TRANSPARENT OPTICAL NETWORKS, VOLS 1 AND 2, 2009, : 1244 - +
  • [7] ABSOLUTE RADIOMETRY WITH FOURIER-TRANSFORM SPECTROMETERS
    DUNCAN, WD
    INFRARED PHYSICS, 1984, 24 (2-3): : 279 - 290
  • [8] Diffraction and line shape of Fourier-transform spectrometers
    Genest, J
    Tremblay, P
    APPLIED OPTICS, 2003, 42 (22) : 4541 - 4548
  • [9] Recent Advances in Fourier-Transform Waveguide Spectrometers
    Cheben, Pavel
    Florjanczyk, Miroslaw
    Bock, Przemek
    Ramos, Carlos A.
    Lamontagne, Boris
    Bogdanov, Alexei
    Janz, Siegfried
    Xu, Dan-Xia
    Vachon, Martin
    Scott, Alan
    Ortega-Monux, Alejandro
    Molina-Fernandez, Inigo
    Solheim, Brian
    Sinclair, Kenneth
    2011 13TH INTERNATIONAL CONFERENCE ON TRANSPARENT OPTICAL NETWORKS (ICTON), 2011,
  • [10] The throughput advantage in imaging Fourier-transform spectrometers
    Descour, MR