摘要
A detailed study of the NORDBALL Ge-BGO Compton suppression spectrometers has been performed. Special emphasis has been given to photoelectron yields of the scintillators, optimisation of charge integration in the electronics and the low energy thresholds of the BGO detectors. The time relation between the Ge detector and the BGO scintillator logic pulses has been studied in detail. Maximum Compton suppression factors of 12.0 and 12.7 have been measured for 60Co and 137Cs γ-rays respectively. Photon events observed between the full energy peak and the Compton edge suggest that other effects than multiple Compton scattering are involved. Such effects are usually not included in Monte Carlo simulations and could be the explanation of the factor of 2 deficiency between calculated and measured suppression ratios.
引用
收藏
页码:73 / 82
相关论文
共 50 条
  • [1] LIMITATION OF THE COMPTON SUPPRESSION IN GE-BGO COMPTON SUPPRESSION SPECTROMETERS
    MOSZYNSKI, M
    BJERREGARD, JH
    GAARDHOJE, JJ
    HERSKIND, B
    KNUDSEN, P
    SLETTEN, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 280 (01): : 73 - 82
  • [2] A NOVEL COMPACT GE-BGO COMPTON-SUPPRESSION SPECTROMETER
    DEVOIGT, MJA
    BACELAR, JC
    MICEK, SL
    SCHOTANUS, P
    VERHOEF, BAW
    WINTRAECKEN, YJE
    VERMEULEN, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 356 (2-3): : 362 - 375
  • [3] TIME PICKOFF METHODS FOR BGO CRYSTALS IN GE-BGO COMPTON SUPPRESSION SPECTROMETER SYSTEMS
    MOSZYNSKI, M
    JOHNSON, A
    KLAMRA, W
    LINDBLAD, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 251 (01): : 115 - 118
  • [4] Performance of a Ge-BGO Compton-suppression spectrometer and its application to photon activation analysis
    Fukuda, K
    Ohkuma, J
    Asano, T
    Satoh, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 114 (3-4): : 379 - 386
  • [5] MULTIELEMENT PHOTON-ACTIVATION ANALYSIS OF A BULK LANTHANUM SAMPLE BY A GE-BGO COMPTON-SUPPRESSION SPECTROMETER
    SATOH, Y
    FUKUDA, K
    OHKUMA, J
    ASANO, T
    TANIGUCHI, R
    FUJISHIRO, M
    APPLIED RADIATION AND ISOTOPES, 1995, 46 (10) : 999 - 1002
  • [6] TRANSVERSE BGO COMPTON SUPPRESSION SHIELD
    HILDINGSSON, L
    BEAUSANG, CW
    FOSSAN, DB
    PIEL, WF
    BYRNE, AP
    DRACOULIS, GD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 252 (01): : 91 - 94
  • [7] COMPTON-SUPPRESSION TESTS ON GE AND BGO PROTOTYPE DETECTORS FOR GAMMASPHERE
    BAXTER, AM
    KHOO, TL
    BLEICH, ME
    CARPENTER, MP
    AHMAD, I
    JANSSENS, RVF
    MOORE, EF
    BEARDEN, IG
    BEENE, JR
    LEE, IY
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 317 (1-2): : 101 - 110
  • [8] TRANSVERSE BGO COMPTON SUPPRESSION SHIELD.
    Hildingsson, L.
    Beausang, C.W.
    Fossan, D.B.
    Piel Jr., W.F.
    Byrne, A.P.
    Dracoulis, G.D.
    Nuclear instruments and methods in physics research, 1986, A252 (01): : 91 - 94
  • [9] TEST AND PERFORMANCE OF A BGO COMPTON-SUPPRESSION SHIELD FOR GAMMASPHERE
    CARPENTER, MP
    KHOO, TL
    AHMAD, I
    JANSSENS, RVF
    LAURITSEN, T
    ANNAN, GA
    BAXTER, AM
    BLEICH, ME
    HARFENIST, S
    MOORE, EF
    TORELLI, M
    VISSER, DW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3): : 234 - 238
  • [10] EVALUATION OF GE(LI) COMPTON SUPPRESSION SPECTROMETERS FOR NON-DESTRUCTIVE RADIOCHEMICAL ANALYSIS
    COOPER, JA
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1970, 6 (01): : 177 - +