Implementation and preliminary investigation of analytical methods for correction of distance-dependent resolution variation and uniform attenuation in 3D brain SPECT

被引:0
|
作者
State Univ of New York, Stony Brook, United States [1 ]
机构
来源
IEEE Trans Nucl Sci | / 6 III卷 / 2162-2171期
关键词
In the past ten years; widely cited inversion methods for correcting the distance-dependent resolution variation can be ‘This work was supported by NIH Grant #HL54166 of the National Heart; Lung; and Blood Institute; Grant #NS33853 of the National Institute of Neurological Disorder and Stroke; Grant #CA79180 of the National Cancer Institute; and Established Investigatorship of the American Heart Association;
D O I
暂无
中图分类号
学科分类号
摘要
35
引用
收藏
相关论文
共 17 条
  • [1] Implementation and preliminary investigation of analytical methods for correction of distance-dependent resolution variation and uniform attenuation in 3D drain SPECT
    Li, J
    Liang, ZR
    Ye, JH
    Han, GP
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) : 2162 - 2171
  • [2] Investigation on analytical methods for correction of distance-dependent resolution variation in 3D SPECT imaging
    State Univ of New York, Stony Brook, United States
    IEEE Nucl Sci Symp Med Imaging Conf, (1620-1624):
  • [3] SIMULTANEOUS CORRECTION OF ATTENUATION AND DISTANCE-DEPENDENT RESOLUTION IN SPECT - AN ANALYTICAL APPROACH
    VANELMBT, L
    WALRAND, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (09): : 1207 - 1217
  • [4] Towards analytical solution for 3D SPECT reconstruction with non-uniform attenuation and distance-dependent resolution variation: A Monte Carlo simulation study
    Lu, HB
    Wen, JH
    Li, X
    Li, TF
    Han, GP
    Liang, ZG
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 20 - 28
  • [5] Analytical solution to Cone-beam SPECT reconstruction with non-uniform attenuation and distance-dependent resolution variation
    Zhang, Hao
    Wen, Junhai
    Yang, Jing
    Hu, Peng
    Liang, Zhengrong
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [6] Short-scan SPECT imaging with non-uniform attenuation and 3D distance-dependent spatial resolution
    Pan, XC
    Sidky, EY
    Kao, CM
    Zou, Y
    Metz, CE
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (15): : 2811 - 2833
  • [7] Toward optimal noniterative reconstruction for 3-D SPECT with uniform attenuation and distance-dependent spatial resolution
    Kao, CM
    Pan, XC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 774 - 781
  • [8] Analytical algorithm for 3D cone-beam SPECT reconstruction with uniform attenuation correction
    Bronnikov, A.V.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 3 : 1417 - 1423
  • [9] A non-iterative solution for quantitative myocardial perfusion SPECT reconstruction with non-uniform attenuation and distance-dependent spatial resolution.
    Lu, H
    Wen, J
    Li, X
    Liang, JZ
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 105P - 105P
  • [10] Towards Quantitative SPECT: Error Estimation of SPECT OSEM with 3D Resolution Recovery, Attenuation Correction and Scatter Correction
    Zeintl, J.
    Vija, A. H.
    Yahil, A.
    Ding, X.
    Hornegger, J.
    Kuwert, T.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3381 - +