Comparison of Outcomes After Anterior Cervical Discectomy and Fusion Using Bioactive Glass-Ceramic Spacer-7 (NOVOMAX-FUSION) and an Allograft Spacer: A Retrospective, Case-Matched, Multicenter Study

被引:0
|
作者
Jang, Gi-Wuk [1 ,2 ]
Kim, Kyung-Hyun [1 ]
Shin, Dong-Ah [2 ,3 ]
Jang, Hyun-Joon [1 ]
Lee, Chang-Kyu [3 ]
Chin, Dong-Kyu [1 ,2 ]
Park, Jeong-Yoon [1 ,2 ]
Koo, Seong-Wook [1 ,2 ]
Moon, Bong-Ju [1 ]
机构
[1] Gangnam Severance Spine Hosp, Spine & Spinal Cord Inst, Dept Neurosurg, Seoul, South Korea
[2] Yonsei Univ, Coll Med, Dept Neurosurg, Seoul, South Korea
[3] Severance Hosp, Dept Neurosurg, Seoul, South Korea
关键词
allograft; BGS-7; bioactive glass-ceramic; cervical fusion; finite element analysis; INTERBODY FUSION; SPINE; HYDROXYAPATITE; SUBSIDENCE; CAGES; SUBSTITUTE; AUTOGRAFT; REMOVAL; BGS-7; RATES;
D O I
10.1002/jbm.b.35521
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The bioactive glass-ceramic spacer (BGS)-7, a biosynthetic intervertebral fusion material introduced in 2014, has not been the subject of comparative clinical studies on anterior cervical discectomy and fusion (ACDF) surgery. This study, for the first time, aims to compare the radiological and clinical outcomes of the renewed BGS-7, released in 2019, with those of an allograft spacer. The comparison includes a finite element analysis of the biomechanical properties of each implant, adding a novel dimension to the research. We prospectively followed up on 29 patients who underwent ACDF using BGS-7 as the experimental group. To select a control group for comparison, 253 patients with level 1 ACDF with an allograft spacer between 2012 and 2022 were selected from our hospital. Using propensity score matching, 27 and 54 patients in the BGS-7 and allograft groups, respectively, were selected. The average subsidence length was 1.02 +/- 1.44 mm per level in the BGS-7 group and 2.27 +/- 2.25 mm per level in the allograft group. Subsidence was observed in 14 of 54 patients (25.9%) in the allograft group and one of 27 patients (3.7%) in the BGS-7 group (p = 0.016). In the allograft group, 16 of the 54 patients (29.6%) monitored for 6 months achieved satisfactory fusion outcomes with grades 4 and 5. Thirty-eight of 54 patients (70.4%) followed up for > 1 year in the allograft group achieved adequate fusion outcomes with grades 4 and 5. In the BGS-7 group, 17 of the 27 patients (63.0%) monitored for 6 months achieved satisfactory fusion results with grades 4 and 5. Twenty-three of the 27 patients (85.2%) followed up for > 1 year obtained adequate fusion outcomes with grades 4 and 5. There was a significant difference in the fusion rates between the two groups at 6 months (p = 0.008). BGS-7 is a reliable instrument for ACDF with no instances of instrumental failure. The BGS-7 group had positive clinical outcomes after surgery without any untoward events, and an early fusion rate with the creation of a bone bridge was noted during the 6-month follow-up period. Our findings not only indicate the safety of BGS-7 but also its practicality as a substitute for allografts in ACDF, instilling confidence in its application.
引用
收藏
页数:11
相关论文
共 8 条
  • [1] Efficacy of Allograft Versus Bioactive Glass-Ceramic Cage in Anterior Cervical Discectomy and Fusion: A Randomized Controlled Study
    Liu, Yanting
    Park, Chan Woong
    Pholprajug, Phattareeya
    Suvithayasiri, Siravich
    Kim, Jung Hoon
    Lee, Chorong
    Kim, Eun
    Kim, Jin-Sung
    GLOBAL SPINE JOURNAL, 2023,
  • [2] Long-term results comparison after anterior cervical discectomy with BGS-7 spacer (NOVOMAX®-C) and allograft spacer: A prospective observational study
    Ryu, Seungjun
    Ryu, Dal-Sung
    Kim, Keun-Su
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [3] Comparison of the effectiveness and safety of bioactive glass ceramic to allograft bone for anterior cervical discectomy and fusion with anterior plate fixation
    Kim, Hyung Cheol
    Oh, Jae Keun
    Kim, Du Su
    Roh, Jeffrey S.
    Kim, Tae Woo
    An, Seong Bae
    Jeon, Hyeong Seok
    Shin, Dong Ah
    Yi, Seong
    Kim, Keung Nyun
    Yoon, Do Heum
    Ha, Yoon
    NEUROSURGICAL REVIEW, 2020, 43 (05) : 1423 - 1430
  • [4] Comparison of the effectiveness and safety of bioactive glass ceramic to allograft bone for anterior cervical discectomy and fusion with anterior plate fixation
    Hyung Cheol Kim
    Jae Keun Oh
    Du Su Kim
    Jeffrey S. Roh
    Tae Woo Kim
    Seong Bae An
    Hyeong Seok Jeon
    Dong Ah Shin
    Seong Yi
    Keung Nyun Kim
    Do Heum Yoon
    Yoon Ha
    Neurosurgical Review, 2020, 43 : 1423 - 1430
  • [5] Comparison of Clinical Outcomes Following Anterior Cervical Discectomy and Fusion with Zero-Profile Anchored Spacer-ROI-C-Fixation and Combined Intervertebral Cage and Anterior Cervical Discectomy and Fusion: A Retrospective Study from a Single Center
    He, Shuangjun
    Zhou, Zhangzhe
    Lv, Nanning
    Shao, Xiaofeng
    Zhou, Xinfeng
    Wang, Yaowei
    Wu, Shuhua
    Chen, Kangwu
    Zhou, Lijian
    Qian, Zhonglai
    MEDICAL SCIENCE MONITOR, 2021, 27
  • [6] A comparison of zero-profile anchored spacer (ROI-C) and plate fixation in 2-level noncontiguous anterior cervical discectomy and fusion- a retrospective study
    Zongyu Zhang
    Yawei Li
    Weimin Jiang
    BMC Musculoskeletal Disorders, 19
  • [7] A comparison of zero-profile anchored spacer (ROI-C) and plate fixation in 2-level noncontiguous anterior cervical discectomy and fusion- a retrospective study
    Zhang, Zongyu
    Li, Yawei
    Jiang, Weimin
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [8] Radiologic Findings and Risk Factors of Adjacent Segment Degeneration after Anterior Cervical Discectomy and Fusion : A Retrospective Matched Cohort Study with 3-Year Follow-Up Using MRI
    Ahn, Sang-Soak
    So, Wan-Soo
    Ku, Min-Geun
    Kim, Sang-Hyeon
    Kim, Dong-Won
    Lee, Byung-Hun
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2016, 59 (02) : 129 - 136