Electrochemical Detection of Cd2+ and Pb2+ in Wastewater by Amino C-dot-MOF/GCE

被引:0
|
作者
Chen, Shaohua [1 ,2 ]
Wang, Yihua [1 ,2 ]
Zhang, Biao [3 ]
Li, Mingming [1 ,2 ]
Zhang, Jinhua [1 ,2 ]
Hu, Qiangfei [1 ,2 ]
Qian, Quan [1 ,2 ]
Liu, Hui [1 ,2 ]
机构
[1] Anhui Jianzhu Univ, Key Lab Funct Mol Design & Interface Proc, Hefei 230601, Anhui, Peoples R China
[2] Anhui Jianzhu Univ, Anhui Key Lab Adv Bldg Mat, Hefei 230601, Anhui, Peoples R China
[3] Anhui Jianzhu Univ, Sch Mat & Chem Engn, Hefei 230026, Anhui, Peoples R China
关键词
sensors; electroanalytical electrochemistry; nanoscale materials; ENHANCED PHOTOCATALYTIC ACTIVITY; METAL-ORGANIC FRAMEWORK; CADMIUM; PERFORMANCE; FABRICATION; ADSORPTION; ADSORBENT; CHROMIUM; CR(VI); SYSTEM;
D O I
10.1149/2162-8777/ad7b73
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Carbon dots(C-dots) and metal-organic frameworks (MOFs) have found widespread applications in sensing, energy storage, and catalysis, yet their utilization in electrochemical sensing remains relatively limited. This study focuses on the preparation of C-dots/UiO-66-NH2 as a modified material on glassy carbon electrodes to detect cadmium and lead ions in water using electrochemical methods. The material was created by utilizing m-phenylenediamine as a C-dots source and amino-functionalized zirconium-based metal-organic frameworks, combining these two popular materials. The presence of amino groups in the structure facilitated the complexation with metal ions, providing an effective interface for metal ion adsorption. Under optimized deposition conditions, C-dots/UiO-66-NH2 demonstrated excellent linearity and low detection limits for metal ions (Cd2+ and Pb2+) within the concentration range of 30 to 180 mu g l(-1). The limits of detection (LOD) were LOD(Cd) = 2.16 mu g l(-1) and LOD(Pb) = 1.08 mu g l(-1) for individual detection, and LOD(Cd) = 2.62 mu g l(-1) and LOD(Pb) = 1.36 mu g l(-1) for simultaneous detection. These results highlight the suitability of C-dots/UiO-66-NH2 for the determination of Cd2+ and Pb2+ in water. Furthermore, the C-dots/UiO-66-NH2/GCE sensor exhibited robust immunity to interference and maintained detection stability, showcasing its potential for practical applications. (c) 2024 The Electrochemical Society ("ECS"). Published on behalf of ECS by IOP Publishing Limited. All rights, including fortext and data mining, AI training, and similar technologies, are reserved
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Fabrication of MOF-177 for electrochemical detection of toxic Pb2+ and Cd2+ ions
    Sangeetha, S.
    Krishnamurthy, G.
    BULLETIN OF MATERIALS SCIENCE, 2019, 43 (01)
  • [2] Rapid Electrochemical Detection of Heavy Metal Ions Pb2+ and Cd2+ in Petroleum Wastewater
    Ye, Hongyong
    Zuo, Guangling
    Li, Rulin
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (11):
  • [3] An overview of microalgae for Cd2+ and Pb2+ biosorption from wastewater
    Nateras-Ramirez, O.
    Martinez-Macias, M. R.
    Sanchez-Machado, D. I.
    Lopez-Cervantes, J.
    Aguilar-Ruiz, R. J.
    BIORESOURCE TECHNOLOGY REPORTS, 2022, 17
  • [4] Amino-carboxyl cellulose for adsorption of Cd2+ and Pb2+
    Gou J.
    Zhang W.
    Wang X.-F.
    Hao D.
    Shen H.
    You N.
    Long W.-Y.
    Chemosphere, 2023, 339
  • [5] Adsorption of heavy metal tolerance strains to Pb2+ and Cd2+ in wastewater
    Li, Dajun
    Zhou, Li
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2018, 25 (32) : 32156 - 32162
  • [6] Adsorption of heavy metal tolerance strains to Pb2+ and Cd2+ in wastewater
    Dajun Li
    Li Zhou
    Environmental Science and Pollution Research, 2018, 25 : 32156 - 32162
  • [7] Rapid CO2-laser scribing fabrication of an electrochemical sensor for the direct detection of Pb2+ and Cd2+
    Chu, Guanglei
    Zhang, Yanyan
    Zhou, Zhongrui
    Zeng, Weixuan
    Chen, Dongfei
    Yu, Siping
    Wang, Jiemin
    Guo, Yemin
    Sung, Xia
    Li, Ming
    NANO RESEARCH, 2023, 16 (05) : 7671 - 7681
  • [8] Preparation of an electrochemical sensor based on BiOCl-MWCNT for Zn2+, Cd2+ and Pb2+ detection
    Huang D.-H.
    Sun Z.-W.
    Chen J.-Y.
    Lin Q.
    Ye R.-H.
    Gao Xiao Hua Xue Gong Cheng Xue Bao/Journal of Chemical Engineering of Chinese Universities, 2021, 35 (06): : 1082 - 1089
  • [9] Structured and graphitized boron doped diamond electrodes: Impact on electrochemical detection of Cd2+ and Pb2+ ions
    Stenclova, Pavla
    Vyskocil, Vlastimil
    Szabo, Ondrej
    Izak, Tibor
    Potocky, Stepan
    Kromka, Alexander
    VACUUM, 2019, 170
  • [10] Determination of Cd2+ and Pb2+ in seawater using a shipborne detection device
    Lai, Zhiwei
    Zhong, Huiling
    ENVIRONMENTAL TECHNOLOGY, 2025,