Operational analysis of a newly untreated sewage source heat pump with a plate heat exchanger

被引:0
|
作者
Qin, Na [1 ]
Tian, He [1 ]
机构
[1] Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, National Demonstration Center for Experimental Mechanical and Electrical Engineering Education, School of Mechanical Engineering, Tianjin University of Technology, Tianj
关键词
Plates (structural components) - Energy conservation - Heat pump systems - Flow velocity - Sewage treatment - Pumps;
D O I
暂无
中图分类号
学科分类号
摘要
Urban untreated sewage is widely used as a heat source in the heat pump system. Sewage energy has typically been extracted indirectly, i.e., by setting up a heat exchanger before the units. Among sewage heat exchangers, the shell-and-tube heat exchanger is widely applied, while the untreated sewage source heat pump system using a plate heat exchanger is less common owing to its special structure requiring a higher quality of sewage treatment and a superior cleaning method. To solve this problem, a specially designed, sewage source heat pump system was developed and tested. It consists of a kind of pretreatment device, i.e. self-designed spiral-flow type sewage filter and automatic backwashing plate sewage heat exchanger. The model of the heat transfer coefficient of the plate heat exchanger is validated through the comparison between the actual operation data and the theoretical value, and then the influence of the sewage flow velocity on the exchanger is analyzed. Finally, the COP value is calculated, and an energy conservation performance evaluation of the complete system is performed. The test results of actual operation show that the COP value of the new sewage source heat pump system proposed in this paper is 3.02. The filter device has good anti-clogging effect, and the heat exchanger runs stably, achieving the expected energy saving effect. © 2021, The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
引用
收藏
页码:683 / 693
相关论文
共 50 条
  • [1] Operational analysis of a newly untreated sewage source heat pump with a plate heat exchanger
    Qin, Na
    Tian, He
    HEAT AND MASS TRANSFER, 2022, 58 (04) : 683 - 693
  • [2] Operational analysis of a newly untreated sewage source heat pump with a plate heat exchanger
    Na Qin
    He Tian
    Heat and Mass Transfer, 2022, 58 : 683 - 693
  • [3] Analysis of Fouling in Sewage Source Heat Pump Heat Exchanger
    Zhang, Xu
    Zhang, Lingzhe
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON CIVIL ENGINEERING AND TRANSPORTATION 2015, 2016, 30 : 804 - 808
  • [4] System simulation of an untreated sewage source heat pump
    Qin N.
    Hao Z.
    International Journal of Simulation: Systems, Science and Technology, 2016, 17 (29): : 27.1 - 27.9
  • [5] Application of a heat pump system using untreated urban sewage as a heat source
    Liu, Zhibin
    Ma, Liangdong
    Zhang, Jili
    APPLIED THERMAL ENGINEERING, 2014, 62 (02) : 747 - 757
  • [6] Application of a heat pump system using untreated urban sewage as a heat source
    Liu, Zhibin
    Ma, Liangdong
    Zhang, Jili
    Applied Thermal Engineering, 2013, 61 (02) : 747 - 757
  • [7] SYSTEM SIMULATION FOR AN UNTREATED SEWAGE SOURCE HEAT PUMP (USSHP) IN WINTER
    Qin, Na
    Hao, Peng Z.
    SEVENTH INTERNATIONAL CONFERENCE ON ELECTRONICS AND INFORMATION ENGINEERING, 2017, 10322
  • [8] Strong self-flushing technique for heat exchanger of sewage source heat pump system
    肖红侠
    孙德兴
    李欣
    Journal of Harbin Institute of Technology(New series), 2010, (01) : 8 - 12
  • [9] Optimization design of untreated sewage source heat pump based on genetic algorithm
    Wu, Xuehui
    Sun, Dexing
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 780 - 783
  • [10] Experimental study on viscosity characteristic of sewage in urban untreated sewage source heat pump system
    吴学慧
    张承虎
    赵明明
    孙德兴
    Journal of Harbin Institute of Technology(New series), 2010, (01) : 82 - 84