摘要
The management of radon in indoor environments is essential owing to its carcinogenic risk, with the main sources being gaseous radon from advection and aqueous radon from degassing. However, methods for apportioning indoor radon sources are limited, due to gaps between preliminary physical information and site-specific measurement. This study proposes a method for apportioning sources utilizing a grey-box model that integrates physical theories with data information. Monitoring of indoor air conditioning was conducted and a grey-box model for indoor radon contamination was established using a signal processing system and a physical-based model. Based on the optimized grey-box model, sources of indoor radon were apportioned. The average radon concentration during the monitoring period was 1104 Bq/m3, which was 7.5 times higher than 148 Bq/m3 , the action level recommended by EPA. The grey-box model showed good performance for predicting indoor radon concentrations. Degassing of aqueous radon was identified as the main source of indoor radon. The estimations provided by the grey-box model showed its potential to assess the contribution of each transport mechanism. Apportioning sources through grey-box modeling is a promising method for developing optimized mitigation strategies and bridging data gaps between the preliminary conceptual site model and site investigation.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Cash Flow Prediction Using a Grey-Box Model
    Pang, Yang
    Opong, Kwaku
    Moutinho, Luiz
    Li, Yun
    2015 21ST INTERNATIONAL CONFERENCE ON AUTOMATION AND COMPUTING (ICAC), 2015, : 371 - 376
  • [2] Grey-box model for model predictive control of buildings
    Klanatsky, Peter
    Veynandt, Francois
    Heschl, Christian
    ENERGY AND BUILDINGS, 2023, 300
  • [3] A grey-box model describing the hydraulics in a creek
    Jónsdóttir, H
    Jacobsen, JL
    Madsen, H
    ENVIRONMETRICS, 2001, 12 (04) : 347 - 356
  • [4] Rotary Dryer Control Using a Grey-Box Neural Model Scheme
    Cubillos, Francisco A.
    Vyhmeister, Eduardo
    Acuna, Gonzalo
    Alvarez, Pedro I.
    DRYING TECHNOLOGY, 2011, 29 (15) : 1820 - 1827
  • [5] A grey-box identification approach for a human alertness model
    Lima, Marcelo
    Romano, Rodrigo
    Pait, Felipe
    Folkard, Simon
    Parro, Vanderlei
    2019 IEEE 58TH CONFERENCE ON DECISION AND CONTROL (CDC), 2019, : 3756 - 3761
  • [6] Grey-box model identification via evolutionary computing
    Tan, KC
    Li, Y
    CONTROL ENGINEERING PRACTICE, 2002, 10 (07) : 673 - 684
  • [7] Grey-box model identification of temperature dynamics in a photobioreactor
    Jimenez-Gonzalez, A.
    Adam-Medina, M.
    Franco-Nava, M. A.
    Guerrero-Ramirez, C. V.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2017, 121 : 125 - 133
  • [8] A Grey-box model approach using noon report data for trim optimization
    Zwart, Robert H.
    Bogaard, Jordi
    Kana, Austin A.
    INTERNATIONAL SHIPBUILDING PROGRESS, 2023, 70 (01) : 41 - 63
  • [9] Development and validation of grey-box model for district heating station
    Czemplik, Anna
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND CYBERNETICS, VOLS 1-7, 2008, : 3397 - 3402
  • [10] GREY-BOX MODEL-BASED VIBRATION ISOLATION USING A DIELECTRIC ELASTOMER ACTUATOR
    Jones, Richard W.
    Sarban, Rahimullah
    ASIAN JOURNAL OF CONTROL, 2013, 15 (06) : 1599 - 1612